Nyc electrician Study guides, Study notes & Summaries

Looking for the best study guides, study notes and summaries about Nyc electrician? On this page you'll find 59 study documents about Nyc electrician.

All 59 results

Sort by

NYC MASTER ELECTRICIAN EXAM| 230 QUESTIONS| WITH COMPLETE SOLUTIONS Popular
  • NYC MASTER ELECTRICIAN EXAM| 230 QUESTIONS| WITH COMPLETE SOLUTIONS

  • Exam (elaborations) • 34 pages • 2023
  • Available in package deal
  • Type ____ is multiconductor cable identified for use as underground service entrance cable. correct answer: Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less correct answer: Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? correct answer: Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided ...
    (1)
  • R251,48
  • 3x sold
  • + learn more
NYC Electrician Exam Q&A PASSED TEST
  • NYC Electrician Exam Q&A PASSED TEST

  • Exam (elaborations) • 19 pages • 2024
  • NYC Electrician Exam Q&A PASSED TEST The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? A) Inverse time B) Ampacity C) Automatic D) Setting - ANSWER D) Setting. The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? A) 30% B) 40% C) 50% D) 60% - ANSWER B) 40 % Chapter 9 Table 1 EMT must be supported within what distance from an outlet b...
    (0)
  • R241,80
  • + learn more
NYC Electrician Exam Q&A PASSED TEST
  • NYC Electrician Exam Q&A PASSED TEST

  • Exam (elaborations) • 19 pages • 2023
  • NYC Electrician Exam Q&A PASSED TEST The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? A) Inverse time B) Ampacity C) Automatic D) Setting - ANSWER D) Setting. The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? A) 30% B) 40% C) 50% D) 60% - ANSWER B) 40 % Chapter 9 Table 1 EMT must be supported within what distance from an outlet b...
    (0)
  • R212,76
  • + learn more
NYC Electrician Exam Q&A PASSED TEST
  • NYC Electrician Exam Q&A PASSED TEST

  • Exam (elaborations) • 19 pages • 2024
  • NYC Electrician Exam Q&A PASSED TEST The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? A) Inverse time B) Ampacity C) Automatic D) Setting - ANSWER D) Setting. The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? A) 30% B) 40% C) 50% D) 60% - ANSWER B) 40 % Chapter 9 Table 1 EMT must be supported within what distance from an outlet b...
    (0)
  • R241,80
  • + learn more
NYC Master Electrician Exam Questions And Answers Graded A+
  • NYC Master Electrician Exam Questions And Answers Graded A+

  • Exam (elaborations) • 19 pages • 2023
  • Available in package deal
  • NYC Master Electrician Exam Questions And Answers Graded A+ NYC Master Electrician Exam Questions And Answers Graded A+ NYC Master Electrician Exam Questions And Answers Graded A+
    (0)
  • R270,84
  • + learn more
NYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATE
  • NYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATE

  • Exam (elaborations) • 19 pages • 2024
  • Available in package deal
  • NYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATENYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATENYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATE Type ____ is multiconductor cable identified for use as underground service entrance cable. - ANSWER-Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER-Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is n...
    (0)
  • R232,12
  • + learn more
NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.
  • NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.

  • Exam (elaborations) • 18 pages • 2023
  • NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.
    (0)
  • R309,55
  • + learn more
NYC Electrician Exam Q&A PASSED TEST
  • NYC Electrician Exam Q&A PASSED TEST

  • Exam (elaborations) • 19 pages • 2024
  • NYC Electrician Exam Q&A PASSED TEST The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? A) Inverse time B) Ampacity C) Automatic D) Setting - ANSWER D) Setting. The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? A) 30% B) 40% C) 50% D) 60% - ANSWER B) 40 % Chapter 9 Table 1 EMT must be supported within what distance from an outlet b...
    (0)
  • R270,84
  • + learn more
NYC MASTER ELECTRICIAN EXAM 100%  VERIFIED
  • NYC MASTER ELECTRICIAN EXAM 100% VERIFIED

  • Exam (elaborations) • 19 pages • 2023
  • Available in package deal
  • NYC MASTER ELECTRICIAN EXAM 100% VERIFIED NYC MASTER ELECTRICIAN EXAM 100% VERIFIED NYC MASTER ELECTRICIAN EXAM 100% VERIFIED NYC MASTER ELECTRICIAN EXAM 100% VERIFIED NYC MASTER ELECTRICIAN EXAM 100% VERIFIED NYC MASTER ELECTRICIAN EXAM 100% VERIFIED NYC MASTER ELECTRICIAN EXAM 100% VERIFIED
    (0)
  • R319,23
  • + learn more