STERILE PROCESSING FINAL EXAM STUDY GUIDE
CHAPTERS 1-23
What is Central Service ? - ANSWER: Centralized distribution of supplies to all customers in the hospital.


What is the Central Service One Way Work Flow ? - ANSWER: -Decontamination (soiled)
-Preparation, Packaging, Sterilization (clean)
-Sterile Storage (sterile)


What is the purpose of a One Way Work Flow ? - ANSWER: To prevent cross contamination.


Decontamination - ANSWER: Physically or chemically render instruments or equipment that may be
contaminated with harmful micro organisms to make it safe to handle.


Negative air flow - ANSWER: Air flows into a room from other surrounding areas, pressure is less than other
adjacent areas.


Positive Air Pressure - ANSWER: Maintains air flow out of a room, this helps with keeping all dust particles and
microorganisms out.


Standard Precautions - ANSWER: Treat everyone and everything as infected /contaminated.


Job Description - ANSWER: Define and communicate job duties and requirements in organization.


Nosocomial Infection - ANSWER: Hospital Acquired Infection.


Textile Packaging Materials should be held at a room temperature of ______ and a relative humidity of ____
for a minimum of __ ____ prior to sterilization. - ANSWER: -64-72 degrees F
-35-70%
-2 Hours

,Superheating - ANSWER: When steam is at a temperature which exceeds that of saturated steam at the same
pressure.


Linen packaging material is limited to a size of _______,not weigh more than _______, and maximum density
must not exceed ______. - ANSWER: -12x12x20
-12 lbs
-7.2 lbs


What is a wet pack? - ANSWER: Containers with moisture after the sterilization process is complete.


What are the 2 flat wrapping techniques and the 2 folds? - ANSWER: -Sequential
-Simultaneous
-Square Fold
-Envelope Fold


Wrapped pans of instruments should not exceed ____ in weight. - ANSWER: 16 lbs


What is the maximum weight for containerized instrument sets recommended by AAMI/ANSI? - ANSWER: 25
lbs


Wrapped basin sets should not exceed _____. - ANSWER: 7 lbs


Sterility (time-related) - ANSWER: Package is considered sterile until a specific expiration date is reached.


Sterility (event-related) - ANSWER: Items are considered sterile unless the integrity of the packaging is
compromised or suspected of being compromised.


Name the 4 things that event-related sterility depends on. - ANSWER: 1. Quality of the wrapping material.
2. Handling procedures.
3. Storage and transport conditions.
4. Number of times the package has been handled (4 times).

, Name 4 concerns when it comes to packaging. - ANSWER: 1. Moisture contamination.
2. Dirt, Dust, and Debris.
3. Physical damage.
4. Breakdown of packaging material due to wear of age.


Sterile Storage standards, temperatures should be at ______ and relative humidity should be less than ____. -
ANSWER: - 64-75 degrees F
- 75%


Sterile storage standards, sterile items should be stored at least ___ away from exterior walls, ______ above
the floor and from the ceiling. - ANSWER: -2 inches
-8-10 inches


What is Passivation? - ANSWER: A chemical process applied during instrument manufacture that provides a
corrosion-resistant finish by forming a thin transparent oxide film.


Scissors 4 1/2" and larger use a ____ test material and scissors 4" or smaller use ______ material to check
blades for sharpness. - ANSWER: -red
-yellow


____ ____ are tested with an index card at least 5 times. ______ should be tested using 3"x 5" index cards. -
ANSWER: -Bone cutters
-Rongeurs


Name at least 10 of the 15 solutions that can damage surgical instruments. - ANSWER: 1. Saline
2. Betadine
3. Peroxide
4. Dish soaps
5. Soaking in water
6. Soaking in saline
7. Bleach

Written for

Institution
Sterile processing technician
Course
Sterile processing technician

Document information

Uploaded on
May 25, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

R175,95
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
DebbiePapers

Get to know the seller

Seller avatar
DebbiePapers Queens College
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
10 months
Number of followers
0
Documents
128
Last sold
7 months ago

0,0

0 reviews

5
0
4
0
3
0
2
0
1
0

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions