CSLB C10 Test 1 Questions And Answers
Latest Update
Practice questions for this set
Learn 1/7 Study with Learn
What is the maximum permitted distance between convenience outlets in
kitchens?
Choose matching definition
18' 216'
314' 412'
Don't know?
Terms in this set (120)
, What is the minimum working 36"
clearance from an electrical panel
under 600 V?
Voltage drop in wire is a function Wire gauge, Length of wire, Current flow in the wire
of:
A 12-volt direct current, 13-watt 156
fluorescent light is controlled by
a
photocell. The average daily on-
time is 12 hours per day. How
many watt- hours are
consumed by the light on an
average day?
Where may you use nonmetallic- inside floors and walls
sheathed cable?
What is the maximum 12'
permitted distance
between convenience
outlets in kitchens?
The minimum permitted size No. 18
fixture wire is:
What is an Erickson coupling to connect two sections of rigid conduit when one section
used for? cannot be turned
The smallest size grounding No. 8 copper
conductor permitted for service
entrance is:
For an electric appliance with a 25 amps
17.5 A load, the overcurrent
device must not exceed:
A 5 kW appliance is used for 5 $0.35
hours.
At $0.014 per kWh, the cost of
running the appliance is:
If the plumber accidentally cuts general contractor
installed wires, to whom should you
report the problem?
What is the maximum distance 24"
to an outlet from any point
along the wall behind a kitchen
counter?
Which of the following materials enamel
is not corrosive?
Latest Update
Practice questions for this set
Learn 1/7 Study with Learn
What is the maximum permitted distance between convenience outlets in
kitchens?
Choose matching definition
18' 216'
314' 412'
Don't know?
Terms in this set (120)
, What is the minimum working 36"
clearance from an electrical panel
under 600 V?
Voltage drop in wire is a function Wire gauge, Length of wire, Current flow in the wire
of:
A 12-volt direct current, 13-watt 156
fluorescent light is controlled by
a
photocell. The average daily on-
time is 12 hours per day. How
many watt- hours are
consumed by the light on an
average day?
Where may you use nonmetallic- inside floors and walls
sheathed cable?
What is the maximum 12'
permitted distance
between convenience
outlets in kitchens?
The minimum permitted size No. 18
fixture wire is:
What is an Erickson coupling to connect two sections of rigid conduit when one section
used for? cannot be turned
The smallest size grounding No. 8 copper
conductor permitted for service
entrance is:
For an electric appliance with a 25 amps
17.5 A load, the overcurrent
device must not exceed:
A 5 kW appliance is used for 5 $0.35
hours.
At $0.014 per kWh, the cost of
running the appliance is:
If the plumber accidentally cuts general contractor
installed wires, to whom should you
report the problem?
What is the maximum distance 24"
to an outlet from any point
along the wall behind a kitchen
counter?
Which of the following materials enamel
is not corrosive?