___ GPM to ___ GPM is the maximum flow recommended for one line of 2 ½ inch hose. A. 150-200 B. 200-250 C. 250-300 D. 300-350 - Correct Answer C "There shall be an OS&Y valve located between the fire department Siamese connection and the standpipe riser" "There is a one way check valve positioned in the system to keep possible contaminated water from entering the main system" A. Both statements are true B. The first statement is true, the second statement is false C. Both statements are false D. The first statement is false, the second statement is true - Correct Answer D 100% of rated capacity at - Correct Answer 150 PSI 50 % of rated capacity at - Correct Answer 250 PSI 70% of rated capacity at - Correct Answer 200 PSI A 2 ½" hose with no nozzle attached (open butt) is flowing at a pressure of 25 psi, how many GPM is being discharged from the opening? A. 375 B. 587 C. 835 D. 937 - Correct Answer C A fire apparatus pump is able to deliver ___ % of its capacity at 15 ft lift. A. 100 B. 70 C. 50 D. 30 - Correct Answer B A large percentage of collisions occur while: A. Leaving quarters B. Railroad crossings C. Backing D. There are adverse weather conditions - Correct Answer C A pressure of one pound per square inch will raise a column of water how many feet? A. 1.341 B. 2.304 C. 3.561 D. 4.221 - Correct Answer B A tank fill line should be provided from the discharge side of the pump. This allows for: A. The tank to be filled without making any additional connections when the pump is being supplied by an external source B. A means of replenishing the water carried in the tank

Show more Read less
Institution
Pump Operator
Course
Pump Operator

Content preview

Pump Operator Exam Prep
___ GPM to ___ GPM is the maximum flow recommended for one line of 2 ½ inch hose.

A. 150-200
B. 200-250
C. 250-300
D. 300-350 - Correct Answer C

"There shall be an OS&Y valve located between the fire department Siamese connection and the standpipe riser"
"There is a one way check valve positioned in the system to keep possible contaminated water from entering the
main system"

A. Both statements are true
B. The first statement is true, the second statement is false
C. Both statements are false
D. The first statement is false, the second statement is true - Correct Answer D

100% of rated capacity at - Correct Answer 150 PSI

50 % of rated capacity at - Correct Answer 250 PSI

70% of rated capacity at - Correct Answer 200 PSI

A 2 ½" hose with no nozzle attached (open butt) is flowing at a pressure of 25 psi, how many GPM is being
discharged from the opening?

A. 375
B. 587
C. 835
D. 937 - Correct Answer C

A fire apparatus pump is able to deliver ___ % of its capacity at 15 ft lift.

A. 100
B. 70
C. 50
D. 30 - Correct Answer B

A large percentage of collisions occur while:

A. Leaving quarters
B. Railroad crossings
C. Backing
D. There are adverse weather conditions - Correct Answer C

A pressure of one pound per square inch will raise a column of water how many feet?

A. 1.341
B. 2.304
C. 3.561
D. 4.221 - Correct Answer B

A tank fill line should be provided from the discharge side of the pump. This allows for:

A. The tank to be filled without making any additional connections when the pump is being supplied by an external
source
B. A means of replenishing the water carried in the tank

, C. The circulation of water through the pump to prevent overheating when no lines are flowing
D. All of the above - Correct Answer D

A tank fill line should be provided from the discharge side of the pump. This allows:

A.The tank to be filled without making additional connections when the pump is drafting.
B.A means of replenishing water carried in the tank.
C.For circulation of water through the pump to prevent overheating when no lines are flowing.
D.All of the above - Correct Answer D

According to NFPA 1901, a mobile water supply apparatus must carry at least:

A. 750 gallons
B. 1000 gallons
C. 1250 gallons
D. 1500 gallons - Correct Answer B

All fire apparatus with a rated pump capacity of 750 gallons or larger must be equipped with ___ 2 ½ " discharges:

A. 2
B. 3
C. 4
D. None of the above - Correct Answer A

Apparatus equipped with a fire pump whose rated capacity is less than 750 GPM are required to undergo the same
certification test as a pumper over 750 GPM with the exception of:

A. Pumping test
B. Pumping engine overload test
C. Vacuum test
D. Water tank to pump flow test - Correct Answer B

Apparatus service tests are conducted at least:

A. Annually
B. Quarterly
C. Semi-Annually
D. As often as local operating procedures dictate. - Correct Answer C

Apparatus with a water tank less than 1000 gallons in size must have a tank fill line at least ___ inches in diameter.

A. 1
B. 2
C. 2 ½
D. 3 - Correct Answer A

Apparatus with air brakes are to be equipped with an air pressure protection valve that prevents air horns from being
operated when the air pressure in the air reservoir drops below:

A. 60 psi
B. 80 psi
C. 100 psi
D. 110 psi - Correct Answer B

At a fire, 6 sprinkler heads have opened. They are operating at a 30 psi pressure. What is the total discharge?

A. 45 GPM
B. 125 GPM
C. 180 GPM
D. 270 GPM - Correct Answer C

Back pressure is also known as ___

Written for

Institution
Pump Operator
Course
Pump Operator

Document information

Uploaded on
September 13, 2024
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

R255,51
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
chaserdreamer

Get to know the seller

Seller avatar
chaserdreamer EXAMS
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
1 year
Number of followers
0
Documents
125
Last sold
-

0,0

0 reviews

5
0
4
0
3
0
2
0
1
0

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions