• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 39 pages
Exam (elaborations)

FDNY COF P-98 Exam & Practice Test 2026/2027 – Complete Exam-Style Questions with Detailed Rationales | 100% Verified – Pass Guaranteed – A+ Graded

Document preview thumbnail
Preview 4 out of 39 pages

FDNY COF P-98 Exam 2026/2027 – Real-Style Exam Questions | 100% Correct Answers | Torch Operations | Fire Safety | Cutting & Welding | Hot Work Permits | FDNY Regulations | Detailed Rationales | Graded A+ Verified – Pass Guaranteed – Instant Download

Content preview

FDNY COF P-98 Exam & Practice Test 2026/2027 – Complete
Exam-Style Questions with Detailed Rationales | 100% Verified –
Pass Guaranteed – A+ Graded


Instructions: Read each question carefully. Select the one best answer. Each question
has only one correct answer.




QUESTION 1

Acetylene gas is stored as a liquid in containers under pressure. What is the maximum
safe working pressure for acetylene when used in welding and cutting operations?

A. 5 psi

B. 10 psi

C. 15 psi

D. 25 psi

Correct Answer: C

Rationale: Per FDNY Fire Code FC 2605.4 and the G-60 study material, acetylene gas
shall not be utilized at a pressure exceeding 15 pounds per square inch gauge (psig).
Setting the regulator above 15 psi can cause the acetylene to decompose explosively.
Acetylene is dissolved in a suitable solvent within the container for safe storage and
use.

,QUESTION 2

True or False: Copper tubing may be used to splice an acetylene hose if the connection
is properly secured.

A. True

B. False

Correct Answer: B

Rationale: FALSE. Per the G-60 study material and FC 2605.4, copper tubing should
never be used to splice acetylene hose. Copper reacts chemically with acetylene, and
the reaction may cause an explosion if the tube is subjected to a physical blow. Only
approved hose connections and fittings designed for acetylene service may be used.




QUESTION 3

A contractor is performing oxy-acetylene cutting on a construction site. According to
FDNY Fire Code Chapter 26, what is the minimum separation distance required between
the cutting operation and combustible materials?

A. 15 feet

B. 25 feet

C. 35 feet

D. 50 feet

Correct Answer: C

,Rationale: Per FC 2604.1.1, hot work operations involving cutting or welding shall be
conducted at least 35 feet from combustible materials and combustible waste, or shall
be provided with appropriate shielding to prevent sparks, slag, or heat from igniting
exposed combustibles. All other hot work operations require a minimum of 25 feet.




QUESTION 4

A fire watch must be maintained during any hot work operation. What is the minimum
duration the fire watch must continue after the conclusion of the work?

A. 15 minutes

B. 30 minutes

C. 45 minutes

D. 60 minutes

Correct Answer: B

Rationale: Per FC 2604.2.1, a fire watch shall be maintained during hot work operations,
and the fire watch shall continue for a minimum of 30 minutes after the conclusion of
the work. The commissioner or the responsible person implementing a hot work
program may extend this duration based on the hazards or work being performed.




QUESTION 5

Which Certificate of Fitness is required for a person conducting torch operations using
oxygen and a flammable gas?

, A. F-60

B. G-41

C. G-60

D. P-98

Correct Answer: C

Rationale: Per FC 2603.4.1 and the G-60 study material, torch operations using oxygen
and a flammable gas, and any torch operation for torch-applied roofing systems, shall
be performed by a G-60 Certificate of Fitness holder. The F-60 is required for fire guards
performing fire watch, not for torch operators.




QUESTION 6

True or False: An FDNY permit is required to conduct hot work using oxygen and a
flammable gas, such as acetylene or propane.

A. True

B. False

Correct Answer: A

Rationale: TRUE. Per FC 2601.2 and the G-60 study material, an FDNY permit is required
to conduct hot work using oxygen and a flammable gas. Additionally, a permit is
required for storing, using, or handling any flammable gas (e.g., LPG, CNG, or acetylene)
in excess of 400 SCF, or any oxidizing gas (e.g., oxygen) in excess of 504 SCF.

Document information

Uploaded on
June 10, 2026
Number of pages
39
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
R274,72

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PrimeScholars
3,2
(13)
Sold
95
Followers
0
Items
3444
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions