RPSGT EXAM REVIEWS WITH CORRECT ANSWERS enhanced artifact - CORRECT ANSWER-The failure to remove electrode paste residue will MOST likely result in: a. discarded electrodes. b. enhanced artifact. c. improved detergent selection. d. improvement in adherence. Initiate emergency response system - CORRECT ANSWER The most appropriate action a technologist would take when there is confirmed ventricular tachycardia lasting greater that 30 seconds is: a. Initiate emergency response system b. Assess, document and continue to monitor c. No immediate response is needed d. Discontinue recording and transport to emergency room Do not use the equipment until the leakage current is lowered. - CORRECT ANSWER-The polysomnograph has a leakage current of 200uA. What should the technician do about this? a. Plug the equipment into an ungro

Show more Read less
Institution
Course











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Study
Course

Document information

Uploaded on
July 11, 2024
Number of pages
32
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

RPSGT EXAM REVIEWS WITH
CORRECT ANSWERS




enhanced artifact - CORRECT ANSWER-The failure to remove
electrode paste residue will MOST likely result in:
a. discarded electrodes.
b. enhanced artifact.
c. improved detergent selection.
d. improvement in adherence.

Initiate emergency response system - CORRECT ANSWER-
The most appropriate action a technologist would take when
there is confirmed ventricular tachycardia lasting greater that 30
seconds is:
a. Initiate emergency response system
b. Assess, document and continue to monitor
c. No immediate response is needed
d. Discontinue recording and transport to emergency room

Do not use the equipment until the leakage current is lowered. -
CORRECT ANSWER-The polysomnograph has a leakage
current of 200uA. What should the technician do about this?
a. Plug the equipment into an ungrounded plug to avoid a
ground loop.
b. Do not use the equipment until the leakage current is
lowered.

,c. Continue to record since this leakage current is within
acceptable limits.
d. Use an extra grounding electrode on the patients

sweat - CORRECT ANSWER-Which of the following conditions
are most likely to cause slow wave artifact in the EEG and EOG
channels?
a .Muscle tension
b. Sweat
c. Incorrect placement of the reference electrodes
d. A and C are correct

c3 - CORRECT ANSWER-The electrode located 30% above
the left pre-auricular crease is:
C3
P3
01
F3

hypoventilation - CORRECT ANSWER-CO2 monitoring, using
either end-tidal or transcutaneous sensors, is mandatory in
children for the scoring of:
A.
Apnea
B.
Hypopnea
C.
Central events
D.
Hypoventilation

capnography - CORRECT ANSWER-What additional
parameter would be MOST helpful to monitor when recording a
patient with COPD?
a. intercostal EMG
b. piezo technology
c. esophageal pressure

,d. capnography

DC - CORRECT ANSWER-Which of these channel types
produces a square calibration wave?
EEG
EMG
Respiratory
DC

unacceptable leak value - CORRECT ANSWER-The most
common reason for changing the PAP interface during titration
is:
a. Sustained desaturations
b. Low sleep efficiency
c. Treatment emergent central apneas
d. Unacceptable leak value

3.2 cm - CORRECT ANSWER-The measured distance from
the nasion to the inion is 32cm. What is the distance from the
inion to Oz?
1.6cm
3.2cm
6.4cm
16cm

high and unequal electrode impedances - CORRECT
ANSWER-Which of the following factors is most likely to cause
60Hz artifact?
a : High and unequal electrode impedance
b. Incorrect low and high frequency filter settings.
c. Incorrect placement of the reference electrodes
d. Direct pressure against one of the electrode

5.8cm - CORRECT ANSWER-The circumferential
measurements is 58cm. What is the distance between O1 &
O2?
2.4 cm

, 5.8 cm
10cm
7.2 cm

less than 5k ohms - CORRECT ANSWER-Which of the
following are the recommended impedance levels for EEG
electrodes?
a. Less then 20,000 ohms
b. Less then 5 ohms
c. Less then 5k ohms
d. At least 20,000 ohms

arm EMG - CORRECT ANSWER-Which of these electrode
sites is not typically used in a baseline montage?
Leg EMG
E2
Arm EMG
Thoracic belt

Recording the differences in the voltages of two inputs -
CORRECT ANSWER-Which of the following is a process
performed by a differential amplifier?
a. Recording the differences in the voltages of two inputs
b. Recording the differences in the voltages of the active input
and ground
c. Recording the differences in the voltages of an exploring
electrode and the patient ground connection
d. Recording only identical voltages received by its two inputs

hunter-cheyne-stokes breathing pattern - CORRECT
ANSWER-Adaptive servo ventilation is an effective treatment
for which of the following disorders?
A.
Obesity hypoventilation syndrome
B.
Nocturnal asthma
C.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TIFFACADEMICS Liberty University
Follow You need to be logged in order to follow users or courses
Sold
671
Member since
2 year
Number of followers
375
Documents
6218
Last sold
1 week ago
REING SUPREME SCHOLARLY // ENLIGHTENED

Here we offer revised study materials to elevate your educational outcomes. We have verified learning materials (Research,Assignments,notes etc...) for different courses guaranteed to boost your academic results. We are dedicated to offering you the best services and you are encouraged to inquire further assistance from our end if need be. Having a wide knowledge in Nursing,trust us to take care of your Academic materials and your remaing duty will just be to Excel. Remember to give us a review,it is key for us to understand our clients satisfaction. We highly appreciate refferals given to us. Also clients who always come back for more of the study content your offer are extremely valued. ALL THE BEST.

Read more Read less
3.7

132 reviews

5
59
4
13
3
33
2
11
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions