Medical physics certification Medical Physics - Board Exam Part 1 - Radiation Therapy | 109 Questions a nd Answers with Complete Solutions 100% Correct | Lat est Update 202 4 PDD is dependent on the following factors - Answer Increases with beam energy Increases with field size Increases with SSD Decreases with Depth TAR is dependent on the following factors - Answer Increases with beam energy Increases with field size Decreases with depth Independent of SSD Skin dose is dependent on the following factors - Answer Decreases with beam energy Increases with SSD Increases with field size Increases with bolus Increases with oblique incidence The indicated field size on a medical LINAC represents the field length and width in centimeters as defined at the: - Answer At isocenter (100 cm) On a conventional simulator, localizing lasers and ODI checks should be performed when and within what tolerance - Answer Daily, 2mm What is the tolerance for light/radiation field coincidence? - Answer 2mm Photon Dmax (cm) - Co60 - Answer 0.5 Photon Dmax (cm) - 4MV - Answer 1.0 Medical physics certification Photon Dmax (cm) - 6MV - Answer 1.5 Photon Dmax (cm) - 10MV - Answer 2.7 Photon Dmax (cm) - 15MV - Answer 3.0 Photon Dmax (cm) - 18MV - Answer 3.2 Photon Dmax (cm) - 20MV - Answer 3.5 Photon Dmax (cm) - 25MV - Answer 4.0 Electron Dmax (cm) - 6MeV - Answer 1.5 Electron Dmax (cm) - 9MeV - Answer 2.2 Electron Dmax (cm) - 10MeV - Answer 2.5 Electron Dmax (cm) - 12MeV - Answer 2.8 Electron Dmax (cm) - 15MeV - Answer 2.9 Electron Dmax (cm) - 18MeV - Answer 3.2 GTV - Answer Gross Tumor Volume CTV - Answer Clinical Target Volume = GTV + margin for microscopic spread ITV - Answer Internal Target Volume = CTV + Internal margin PTV - Answer Planning Target Volume = ITV + Setup margin PRV - Answer Planning Risk Volume = defined as the OAR plus a margin to account for patient movement and setup uncertainties
Exam (elaborations)
Medical Physics - Board Exam Part 1 - Radiation Therapy | 109 Questions and Answers with Complete Solutions 100% Correct | Latest Update 2024
Rating
Sold
2
Pages
10
Grade
A+
Uploaded on
10-01-2024
Written in
2023/2024
Medical Physics - Board Exam Part 1 - Radiation Therapy | 109 Questions and Answers with Complete Solutions 100% Correct | Latest Update 2024
Institution
Medical Physics Certification
Course
Medical physics certification
Whoops! We can’t load your doc right now. Try again or contact support.
Written for
- Institution
- Medical physics certification
- Course
- Medical physics certification
Document information
- Uploaded on
- January 10, 2024
- Number of pages
- 10
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
medical physics
-
board exam part 1
-
radiation therapy
-
medical physics board exam part 1 radiation
-
pdd is dependent on the following factors
-
tar is dependent on the following factors
Content preview
CA$14.14
Get access to the full document:
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal
Package deal
Medical physics certification BUNDLED Exam Actual Questions and Answers 100% Correct ( WELL ILLUSTRATED & DETAILED) | New Update 20242025 | RATED A+
25
2024
CA$ 426.26
More info