What degree is used for isometric drawings? - CORRECT ANSWER-60 degrees
What is the recommended minimum of minutes for chlorine water management? - CORRECT
ANSWER-20-30 minutes
When you need to repair a single handle lavatory faucet, what needs to be replaced? - CORRECT
ANSWER-O ring
Who can approve a backflow prevention device? - CORRECT ANSWER-The authority having
jurisdiction
Testing on a backflow prevention device shall be done by - CORRECT ANSWER-a certified
backflow assembly tester
The minimum vertical length for a gravity type water heater vent is - CORRECT ANSWER-5 feet
All of the following types of fire vents serving a gas fired water heater may pass through a wall or
ceiling except - CORRECT ANSWER-a single wall vent
The minimum elevation at which a vacuum breaker may be installed above the flood level rim of
the device it services is called the - CORRECT ANSWER-critical level
What is the minimum backflow preventer for a flushometer valve? - CORRECT
ANSWERAtmospheric Vacuum Breaker (AVB)
PVB - CORRECT ANSWER-Pressure Vacuum Breaker
,Thank you for Purchasing this exam
Study Guide. We provide high-quality
academic materials to help students
excel in exams. Our other Services
include but not limited to: academic
research, University & College
assignments writing, essay writing,
Online Classes, and research projects.
Our services are reliable, affordable,
and plagiarism-free. All the Best in
your Exam. For more information;
Contact us at:
or
0R +254
741484450
RPPB - CORRECT ANSWER-Reduced Pressure Principle Backflow
, Water closet tank ballcocks shall be installed with vacuum breaker critical level at least - CORRECT
ANSWER-1 inch above the full opening of the overflow tube
A bathtub spout with an effective opening of 1 inch in diameter is not affected by the nearest
sidewall. What minimum distance is required for the tub filler spouts air gap. - CORRECT
ANSWER-2 inches
For water pipe safety prevention, what is the minimum backflow prevention? - CORRECT
ANSWERPressure vacuum breaker
Direct connections between the potable water supply and sewer-connected wastes - CORRECT
ANSWER-shall not exist under any condition
Ballcocks in water closet tanks shall be installed so that the critical level of the vacuum breaker
or the bottom of the water inlet is above the full opening of the overflow pipe, at least -
CORRECT ANSWER-1 inch
What type of vacuum breaker is used for swimming pools? - CORRECT ANSWER-Atmospheric
vacuum breaker
Water pipes that supply swimming pools require what minimum backflow protection? - CORRECT
ANSWER-Atmospheric vacuum breaker
Type __________ copper water pipe shall not be installed below grade under a building. -
CORRECT ANSWER-M
If a contractor takes great care in removing an old 2 inch copper pipe from a heating system and
caps the ends so no debris can enter, what must he do to use the material in another potable water
system? - CORRECT ANSWER-This is NOT ALLOWED by the code