100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Texas Fire Alarm Exam 2026 | All Questions and Correct Answers | Graded A+ | Verified Answers | Brand New Version | Just Released

Puntuación
-
Vendido
-
Páginas
46
Grado
A+
Subido en
20-12-2025
Escrito en
2025/2026

Texas Fire Alarm Exam 2026 | All Questions and Correct Answers | Graded A+ | Verified Answers | Brand New Version | Just Released

Institución
Texas Fire Alarm
Grado
Texas Fire Alarm











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Texas Fire Alarm
Grado
Texas Fire Alarm

Información del documento

Subido en
20 de diciembre de 2025
Número de páginas
46
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Texas Fire Alarm Exam 2026 | All Questions and
Correct Answers | Graded A+ | Verified Answers |
Brand New Version | Just Released

What does PLFA stand for? ---------CORRECT ANSWER-----------------Power Limited
Fire Alarm




What does NPLFA stand for? ---------CORRECT ANSWER-----------------Non-Power
Limited Fire Alarm




What material must NPLFA circuit conductors be made from? ---------CORRECT
ANSWER-----------------Only solid or stranded copper is permitted.




What is a single station detector? ---------CORRECT ANSWER-----------------Battery
powered smoke detectors that do not communicate off premises.




What is a multiple station detector? ---------CORRECT ANSWER-----------------Mains
powered smoke detectors with battery backup that are linked together, so that if
one unit initiates, alarms in all detectors will sound. They do not communicate off
premises.

,How frequently must household single and multiple station detectors be
inspected and tested? ---------CORRECT ANSWER-----------------In accordance with
the manufacturers recommendations, at least monthly




How frequently must household fire alarm systems be inspected and tested? ------
---CORRECT ANSWER-----------------At least every 3 years, by a qualified service
technician.




How frequently must heat detectors be tested? ---------CORRECT ANSWER-----------
------Two or more annually different detectors must be tested each year though
and within 5 years all detectors must have been tested.




What does 'restorable' mean? ---------CORRECT ANSWER-----------------The detector
can be 'restored' or ' reused ' after it has initiated an alarm.




What does 'non-restorable' mean? ---------CORRECT ANSWER-----------------The
detector cannot be 'reused' after it has initiated an alarm. (Think of a heat
detector, which self-destructs upon initiating.)




What size conductors are permitted? ---------CORRECT ANSWER-----------------Size
18AWG and 16AWG are permitted, provided they do not exceed certain rated
ampacities.

,What is used to protect transformers or other devices supplied from power-
supply conductors? ---------CORRECT ANSWER-----------------An over-current device
not rated over 20 Amperes.




When located within 7ft of the floor, how shall cables be fastened? ---------
CORRECT ANSWER-----------------Cables shall be fastened in an approved manner at
intervals of not more than 18 inches.




Single conductors shall not be smaller than BLANK AWG ---------CORRECT
ANSWER-----------------18




Conductors of 26AWG shall only be permitted in which circumstances? ---------
CORRECT ANSWER-----------------Where spliced with a connector listed as suitable
for 26 to 24 AWG




How should PLFA conductors NOT be installed? ---------CORRECT ANSWER-----------
------PLFA conductors shall not be strapped, taped or attached to the exterior of
any conduit or raceway.




What is a Plenum cable? What are its characteristics? ---------CORRECT ANSWER---
--------------Cable that can be installed in ducts, plenums or other spaces used for

, environmental air. It has adequate fire resistance and low smoke-producing
characteristics.




What is Riser cable? What are its characteristics? ---------CORRECT ANSWER---------
--------Cable to be used in vertical wire runs in shafts or between floors. Not to be
used where Plenum cable is required. It is capable of preventing fire from rising
floor-to-floor.




What is General Purpose cable? What are its characteristics? ---------CORRECT
ANSWER-----------------Cable for general purpose fire alarm use. Not to be used
where Plenum or Riser cable is required. It is resistant to the spread of fire.




What 'type' shall plenum cable be? What substitutions are allowed'? ---------
CORRECT ANSWER-----------------Power Limited Fire Alarm Plenum (FPLP) CMP can
be substituted.




What 'type' shall riser wire be? What substitutions are permitted? ---------
CORRECT ANSWER-----------------Power Limited Fire Alarm Riser (FPLR) CMP, FPLP,
CMR can be substituted.




What 'type' shall general purpose wire be? What substitutions are permitted? -----
----CORRECT ANSWER-----------------Power Limited Fire Alarm (FPL) CMP, FPLP,
CMR, FPLR, CMG and CM can be substituted. (All types)
$25.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
StudyWay Capella University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
105
Miembro desde
2 año
Número de seguidores
43
Documentos
1826
Última venta
3 horas hace
INVEST AND UNLEASH THE POWER OF KNOWLEDGE NOW!

THIS PREMIUM STUVIA ACCOUNT GIVES YOU ACCESS TO EXCLUSIVE EXAMS, FLASH CARDS, TEST BANKS, AND STUDY GUIDES TAILORED FOR YOUR SUCCESS. ELEVATE YOUR GRADES, ACCELERATE YOUR LEARNING, AND SUPERCHARGE YOUR STUDIES: DIVE INTO A WORLD OF ACADEMIC EXCELLENCE!

4.5

59 reseñas

5
46
4
5
3
3
2
2
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes