S-12 CITYWIDE SPRINKLER SYSTEMS
________ NOZZLES ARE USED FOR TRANSFORMER VAULTS AND OTHER
HAZARDOUS AREAS. - ------------ANS: OPEN-FIXED
________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT
BE HEATED TO PREVENT FREEZING. - ------------ANS: DRY PIPE
_________ ARE ABLE TO SUPPLY FEED MAINS OR CROSS MAINS DIRECTLY. -
------------ANS: RISERS
_________ SPRINKLERS HAVE BEEN RECALLED. - ------------ANS: CYCLING
_________ SYSTEMS ARE USED FOR THE PROTECTION OF SPECIAL
HAZARDOUS OCCUPANCIES. - ------------ANS: FOAM SUPPLY
_________ SYSTEMS ARE USUALLY FOUND IN BASEMENTS OR OTHER
DIFFICULT TO REACH AREAS. - ------------ANS: PERFORATED PIPE
__________ SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND
FLOW PRESSURES BEFORE AND AFTER. - ------------ANS: DRAIN TEST
RESULTS
__________ SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF
THE FIRE DEPT. THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. -
------------ANS: RECORDS
__________ SHALL NOT BE USED TO FASTEN THE SYSTEM OR BUILDING
ATTACHMENTS TO THE STRUCTURE. - ------------ANS: NAILS
, __________ TANKS ARE MADE OF WOOD, STEEL, OR CONCRETE. -
------------ANS: GRAVITY
__________ VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. -
------------ANS: COLD WEATHER
___________ ARE DESIGNED TO TAKE WATER FROM A SUPPLY AND
DISCHARGE IT UNDER PRESSURE. - ------------ANS: FIRE PUMPS
____________ LINES ARE DIRECTLY CONNECTED TO SPRINKLER HEADS. -
------------ANS: BRANCH
A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE
AND ANY SECTIONAL VALVES. - ------------ANS: MASTER FIRE SUPPRESSION
PIPING CONTRACTOR
A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE
STANDPIPE AND SPRINKLER SYSTEMS. - ------------ANS: MASTER FIRE
SUPPRESSION PIPING CONTRACTOR (MFSPC)
A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO
INDICATE THE SYSTEM IS PARTIALLY OUT OF SERVICE. - ------------ANS: BLUE
A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO
INDICATE THE SYSTEM IS FULLY OUT OF SERVICE. - ------------ANS: WHITE
A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL
OCCUPANCIES WITH _________ SPRINKLER HEADS OR LESS. - ------------ANS:
30
________ NOZZLES ARE USED FOR TRANSFORMER VAULTS AND OTHER
HAZARDOUS AREAS. - ------------ANS: OPEN-FIXED
________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT
BE HEATED TO PREVENT FREEZING. - ------------ANS: DRY PIPE
_________ ARE ABLE TO SUPPLY FEED MAINS OR CROSS MAINS DIRECTLY. -
------------ANS: RISERS
_________ SPRINKLERS HAVE BEEN RECALLED. - ------------ANS: CYCLING
_________ SYSTEMS ARE USED FOR THE PROTECTION OF SPECIAL
HAZARDOUS OCCUPANCIES. - ------------ANS: FOAM SUPPLY
_________ SYSTEMS ARE USUALLY FOUND IN BASEMENTS OR OTHER
DIFFICULT TO REACH AREAS. - ------------ANS: PERFORATED PIPE
__________ SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND
FLOW PRESSURES BEFORE AND AFTER. - ------------ANS: DRAIN TEST
RESULTS
__________ SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF
THE FIRE DEPT. THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. -
------------ANS: RECORDS
__________ SHALL NOT BE USED TO FASTEN THE SYSTEM OR BUILDING
ATTACHMENTS TO THE STRUCTURE. - ------------ANS: NAILS
, __________ TANKS ARE MADE OF WOOD, STEEL, OR CONCRETE. -
------------ANS: GRAVITY
__________ VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. -
------------ANS: COLD WEATHER
___________ ARE DESIGNED TO TAKE WATER FROM A SUPPLY AND
DISCHARGE IT UNDER PRESSURE. - ------------ANS: FIRE PUMPS
____________ LINES ARE DIRECTLY CONNECTED TO SPRINKLER HEADS. -
------------ANS: BRANCH
A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE
AND ANY SECTIONAL VALVES. - ------------ANS: MASTER FIRE SUPPRESSION
PIPING CONTRACTOR
A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE
STANDPIPE AND SPRINKLER SYSTEMS. - ------------ANS: MASTER FIRE
SUPPRESSION PIPING CONTRACTOR (MFSPC)
A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO
INDICATE THE SYSTEM IS PARTIALLY OUT OF SERVICE. - ------------ANS: BLUE
A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO
INDICATE THE SYSTEM IS FULLY OUT OF SERVICE. - ------------ANS: WHITE
A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL
OCCUPANCIES WITH _________ SPRINKLER HEADS OR LESS. - ------------ANS:
30