MASTER ELECTRICIAN TEST 211 COMPLETE
STUDY GUIDE AND ANSWERS

◉ 1. Answer: At least_____ 125 V, single phase, 15 A or 20 A, duplex
with ground-fault circuit interrupter receptacle shall be provided in
each elevator machine room and elevator machinery space.


◉ 25A. Answer: 21. Lighting systems covered by Article 411 shall
have a power supply rated not more than______and not more than
30V


◉ 90. Answer: Temporary electrical power and lighting installations
shall be permitted for a period not exceeding ____days for Christmas
decorative lighting and similar purposes


◉ 10'. Answer: Lighting systems operating at 30V or less shall not
be·installed within_______of pools, spas, fountains, or similar
locatipns


◉ 12 /40. Answer: Where communications wires and cables and
electric light or power conductors are supported by the same pole
and are run paralled to each other in span , the·supply service drops
of 0-750 volts running above and parallel to communications service
drops shall have a minimum separation of _______inches at any point
in the

,span, including the point of and at their attachment to the building,
provided the nongrounded conductors are insulated and that a
clearance of not less than_______ inches is maintained between the
two services at the pole


◉ 8. Answer: Communications Wires and cables shall have a vertical
clearance of not less the ______feet from all points of
roofs above which they pass.


◉ Cable Tray. Answer: MV cable rated 35 KV cannot be installed in


◉ in a straight line. Answer: 6. The grounding of communications
wires should be run to the grounding electrode:


◉ 10 AWG Copper. Answer: 7. Service Lateral conductors that supply
power to limited loads of a single branch circuit-such as a small
polyphase power, controlled water heaters, and similar loads-shall
not be smaller than


◉ 35KV. Answer: Dry type transformers installed indoors rated
over._______ shall be installed in a vault.


◉ 1 1/2". Answer: Flat:top underfloor raceways over 4 inches, but
less 8 inches wide, with a minimum 1 inch spacing between
raceways, shall be covered with concrete to a depth of not iess than

, 1 inch. Raceways spaced less that 1 inch apart shall be covered with
a concrete to a depth of


◉ 48 times. Answer: For straight pulls, the length of a pull box shall
not be less than _____ time the outside diameter, over the sheath, of
the largest shielded ·or lead covered conductor or cable entering the
box on systems over 600 volts


◉ 36". Answer: For switchboards that are not totally enclosed, a
space of ____ or more shall be provided between toe top of the
switchboard and any combustible ceiling


◉ 115%. Answer: A disconnecting means that serves a hermetic
refrigerant motor compressor shall have an ampere rating of at least
percent of the nameplate rated load current or branch circuit
selection current, whichever is greater.


◉ CL2 and CL3. Answer: 15. Class 2 and class 3 cables listed as
suitable for general purpose use with the exception of risers, ducts,
plenums, and other spaces used for environmental air, shall be Type
______


◉ 3 inches. Answer: Branch circuit conductors within _____of a
ballast shall have an insulation temperature rating not lower than 90
degree Cor 194 degree F

Información del documento

Subido en
24 de noviembre de 2025
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GradeGalaxy
4.2
(15)
Vendido
175
Seguidores
5
Artículos
56731
Última venta
2 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes