1 | Page



Backflow Assembly Tester Cert. Workshop
Questions and Correct Answers
1. Backflow is the undesirable reversal of flow of water or other
substances

through a cross

connection into the public water system or consumer's:

a. non potable water system.

b. used water system or consumer's potable water system.

c. public water system or consumer's potable water system.

d. public water system or consumer's non potable system. Ans: c.
public water system or consumer's potable water system.

2. An approved air gap (AG) is a physical separation between the
free-flowing

end of a:

a. non potable water supply pipeline and the overflow rim of an
open or

non-pressurized

receiving vessel.



© 2025 All rights reserved

, 2 | Page

b. potable water supply pipeline and the overflow drain of an open
or

non-pressurized receiving

vessel.

c. potable water supply pipeline and the overflow rim of an open
or

pressurized receiving

vessel.

d. potable water supply pipeline and the overflow rim of an open
or

non-pressurized receiving

vessel. Ans: d. potable water supply pipeline and the overflow rim
of an open or

non-pressurized receiving

vessel.

3. An indirect cross-connection is one that is subject to what type
of backflow?

a. only backsiphonage

b. only backpressure



© 2025 All rights reserved

, 3 | Page

c. only low hazard, backsiphonage or backpressure

d. high or low hazard, backsiphonage or backpressure Ans: a. only
backsiphonage

4. Cross-connections between the potable water piping and any
piping or

containers

containing substances not approved as potable water must be
either

eliminated or

controlled by the installation of an:

a. air gap or a backflow prevention device.

b. approved air break or an backflow prevention device.

c. approved air gap or an approved backflow prevention device.

d. approved air gap or an approved backflow prevention assembly.
Ans: d. approved air gap or an approved backflow prevention
assembly.

5. While testing CV#2 of a DCVA, if CV #2 leaks, the BAT would
observe that the

water flow:




© 2025 All rights reserved

, 4 | Page

a. stops from the sight tube at TC #3 and no differential shows on
the gauge.

b. stops from the sight tube at TC #4 and at least 1.0 psid shows
on the gauge.

c. continues from the sight tube at TC #4 and at least 1.0 psid
shows on gauge

d. stops from the sight tube at TC #4 and no differential shows on
the gauge. Ans: d. stops from the sight tube at TC #4 and no
differential shows on the gauge.

6. Service protection is a way to protect a public water system
from contamination due to backflow from the customer's water
system by the installing an approved

backflow preventer at the:

a. service connection which is considered to be at or near the
water meter.

b. service connection which is considered to be the end of the
customer's potable water system furthest from the meter

c. point of use which is considered to be the start of the
customer's potable

water system where the pipe goes through the outside wall of the
building.

d. point of use which is normally considered to be inside the
building. Ans: a. service connection which is considered to be at or
near the water meter.


© 2025 All rights reserved

Información del documento

Subido en
24 de noviembre de 2025
Número de páginas
46
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Axpert
3.8
(127)
Vendido
592
Seguidores
168
Artículos
29611
Última venta
4 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes