100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

ABC Wastewater Level 3 – General questions and answers

Puntuación
-
Vendido
-
Páginas
67
Grado
A+
Subido en
11-11-2025
Escrito en
2025/2026

Prepare for the ABC Wastewater Level 3 certification exam with this 2025 study guide. Features practice questions on treatment processes, equipment, safety, and management for advanced operators. Wastewater exam, ABC Level 3, operator certification, practice test, treatment plant, activated sludge, anaerobic digestion, chlorination, safety procedures, management, 2025 guide

Mostrar más Leer menos
Institución
ABC Wastewater Level 3
Grado
ABC Wastewater Level 3











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ABC Wastewater Level 3
Grado
ABC Wastewater Level 3

Información del documento

Subido en
11 de noviembre de 2025
Número de páginas
67
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Vista previa del contenido

ABC Wastewater Level 3 – General questions
and answers 2025\2026
Turbidity in wastewater is caused by
A. color
B. dissolved calcium
C. hardness
D. finely divided suspended material correct answer D. finely divided suspended
material


The gas most commonly associated with septic wastewater is
A. carbon dioxide
B. carbon monoxide
C. hydrogen sulfide
D. methane correct answer C. hydrogen sulfide


How many cubic meters per second in 10 MGD?
A. 0.44
B. 1.44
C. 4.73
D. 24.62 correct answer A. 0.44


Mechanical ventilation of a lift station is required to
A. lower temperatures to reduce proportion of hydrogen sulfide
B. reduce chlorine demand
C. reduce corrosion

,D. increase DO in raw wastewater correct answer C. reduce corrosion


A wet well probe is usually used for ________ determination(s) of level.
A. approximate
B. dual point
C. continuous
D. single point correct answer D. single point


A pump is delivering at less than the expected rate of discharge. Which of the
causes listed below is incorrect?
A. speed of motor too low
B. pump not primed
C. impeller clogged
D. discharge head too low correct answer D. discharge head too low


Metal pipes often fail because of
A. back siphonage
B. browning movement
C. galvanic action
D. reverse osmosis correct answer C. galvanic action


When a fire hydrant is operated, it should be
A. just opened enough to have a flow
B. opened fully
C. opened halfway

,D. regulated to flow required correct answer B. opened fully


If the pump bearings on horizontal centrifugal pumps are over lubricated, the
most important effect is that the extra lubricant
A. will result in smoother and more efficient operation of the pump
B. will not make any difference in the operation of the pump
C. will be wasted
D. shaft or shaft sleeve will be damaged correct answer D. shaft or shaft sleeve
will be damaged


If packing is not maintained properly,
A. cavitation damage will result
B. impeller will corrode
C. loss of suction due to air being allowed to enter pump
D. shaft or shaft sleeve will be damaged correct answer C. loss of suction due to
air being allowed to enter pump


Air flow through a trickling filter when the influent is warmer than the air
temperature is
A. upward through the filter
B. downward through the filter
C. inadequate and may require forced air ventilation
D. improved by decreasing the recirculation correct answer A. upward through
the filter

, An active sludge in the aeration tank with an abundant available food supply will
have a relatively
A. high oxygen uptake and fast settling rate
B. high oxygen uptake and slow settling rate
C. low oxygen uptake and fast settling rate
D. low oxygen uptake and slow settling rate correct answer B. high oxygen uptake
and slow settling rate


The reaction of chlorine and ammonia produces a compound which is called
A. ammonium chloride
B. chloral hydrate
C. chloramine
D. hydrazine correct answer C. chloramine


A malfunctioning gas chlorination system has normal gas pressure, no feed rate
indicated on rotometer, and no injector vacuum. What is the most likely cause of
the
problem?
A. air leak upstream of rotameter
B. gas line plugged
C. injector clogged
D. pressure reducing valve diaphragm ruptured correct answer C. injector
clogged


What is the impact of increased viscosity on the effectiveness of mixed media
filters?
$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectgrayson Chamberlain College Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
28
Miembro desde
6 meses
Número de seguidores
5
Documentos
1326
Última venta
1 semana hace

2.8

5 reseñas

5
0
4
1
3
3
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes