COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW
VERSION!!
A sprinkler system is a - CORRECT ANSWER- fire extinguishing system, other than a water mist
system, that utilizes water as the extinguishing agent.
Inspection, testing, servicing and other maintenance of sprinkler systems must be - CORRECT
ANSWER- personally supervised and be performed in accordance with NFPA (National Fire
Protection Association) #25 2011 edition.
All multiple dwellings, factories, office buildings, warehouses, stores and offices, theaters and
music halls, hospitals and asylums, and all public schools and other public buildings, churches
and other places where large numbers of persons are congregated for purposes of worship,
instruction, amusement, and all piers, bulkheads, wharves, pier sheds, bulkhead sheds or other
waterfront structures shall provide - CORRECT ANSWER- fire extinguishers, buckets, axes, fire
hooks, fire doors and other means of preventing and extinguishing fires as the commissioner
may direct.
Required fire protection systems shall be extended or altered as necessary to maintain and
continued protection whenever - CORRECT ANSWER- the building or structure is altered. Systems
not complying with this section shall be considered to be impaired.
,Buildings (4.1.1.1) - Shall be inspected (how often) the building owner shall ensure that all areas
of the building containing water-filled piping shall be maintained at a minimum temperature of
40°F and not exposed to freezing conditions - CORRECT ANSWER-
When the pump is in operation a small water leak on the pump bearings is desirable and should
not be considered a malfunction. Additionally, water should discharge from a ---- relief valve
(electric pump) or --- exchanger (diesel pump) while the fire pump is operating under a "no-
flow" condition. - CORRECT ANSWER- circulation /heat
It shall be unlawful to install or maintain any fire protection system or device that has -
CORRECT ANSWER- the physical appearance of fire protection equipment but that does not
perform a fire protection function where it may be confused with actual fire protection
equipment. An example would be a CCTV camera that is installed inside a shell that resembles a
sprinkler head
SPRINKLER AND/OR STANDPIPE SYSTEM MAINTENANCE AND INSPECTIONS - CORRECT ANSWER-
1. Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained as
required by NFPA #25 2011 edition by a competent person holding a S-12 Certificate of Fitness
and employed or contracted by the owner, to see that all parts of the system are in good
working order, and that the Fire Department connection(s), if any, are ready for immediate use
by the Fire Department. A detailed record shall be kept on the premises or other approved
location, for a minimum of 3 years for examination by any representative of the Fire
Department. - CORRECT ANSWER-
2.A supply of at least six extra sprinkler heads shall be kept available on the premises, to
replace promptly any fused or damaged sprinklers. Any head which has opened or has been
damaged shall be replaced immediately with sprinkler head of similar characteristics such as
operating temperature, orifice size, deflector orientation and thermal sensitivity. - CORRECT
ANSWER-
3. At least once every five years, the Fire Department connection or connections for a sprinkler
system shall be subjected to a hydrostatic pressure test to demonstrate its suitability for Fire
,Department use. The test shall be arranged to be conducted by a Master Fire Suppression
Piping Contractor in the presence of a Fire Department representative.
The contractor shall be hired by the owner or the owner's representative. - CORRECT ANSWER-
4.There shall be one or more employees or individuals contracted by the owner with a
Certificate of Fitness to inspect the sprinkler system following the standard of the NFPA 25 of
2011. - CORRECT ANSWER-
Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained as
required by NFPA #25 2011 edition by - CORRECT ANSWER- competent person holding a S-12
Certificate of Fitness and employed or contracted by the owner, to see that all parts of the
system are in good working order, and that the Fire Department connection(s), if any, are ready
for immediate use by the Fire Department.
A detailed record shall be kept on the premises or other approved location, for a minimum of -
CORRECT ANSWER- 3 years for examination by any representative of the Fire Department.
A supply of at least----extra sprinkler heads shall be kept available on the premises, to replace
promptly any fused or damaged sprinklers. - CORRECT ANSWER- 6
Any head which has ----or has been----1. shall be replaced immediately with sprinkler head of
similar characteristics such as operating temperature, orifice size, deflector orientation and
thermal sensitivity. - CORRECT ANSWER- opened/damaged
At least once every ---- years - CORRECT ANSWER- Fire Department connection or connections
for a sprinkler system shall be subjected to a hydrostatic pressure test to demonstrate its
suitability for Fire Department use.
, At least once every five years, the Fire Department connection or connections for a sprinkler
system shall be subjected to a hydrostatic pressure test to demonstrate its suitability for Fire
Department use. The test shall be arranged to be conducted by a ----by a----The contractor shall
be hired by----- - CORRECT ANSWER- Master Fire Suppression Piping Contractor/1. a Fire
Department representative/the owner or the owner's representative.
There shall be---more employees or individuals contracted by the owner with a----Certificate of
Fitness 1. inspect the sprinkler system following the standard of the NFPA 25 of 2011. -
CORRECT ANSWER- one/COF
II. RESPONSIBILITY OF THE BUILDING OWNER - CORRECT ANSWER-
It shall be the -----'s responsibility to maintain the sprinkler system and to determine the
individual qualifications and competencies of the COF holder that performs the functions
related to inspection, testing and maintenance of such system. - CORRECT ANSWER- owner's
The building owner shall assign an ----to comply with the requirements of study material. -
CORRECT ANSWER- impairment coordinator
The impairment coordinator shall take the action(s) when - CORRECT ANSWER- a standpipe
system, sprinkler system or fire alarm system is out of service.
The impairment coordinator shall maintain records of all - CORRECT ANSWER- system
inspections, tests, servicing and other items of maintenance
The impairment coordinator's records of system inspections, tests, servicing and other items of
maintenance shall be kept on the premises or other approved location for a minimum of --- and
made available for inspection by any member of---- - CORRECT ANSWER- 3 years/FDNY