100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Q-01 FDNY Exam – Questions and Answers |Verified 100% Correct|

Puntuación
-
Vendido
-
Páginas
28
Grado
A+
Subido en
07-11-2025
Escrito en
2025/2026

Q-01 FDNY Exam – Questions and Answers |Verified 100% Correct| One characteristic of a synchronous motor is that it operates at A) high starting torque B) constant speed C) causes lagging power factor D) all of the above - ANSWER -B) constant speed If during does not occur in a refrigerating system, what is the result? A) High-head pressure B) Low-condenser pressure C) Low-head pressure D) None of the above - ANSWER -A) High-head pressure A wound-rotor induction motor with external resistance is a A) multispeed motor B) constant-speed motor C) single-speed motor D) waterproof cover - ANSWER -A) multispeed motor In a Freon refrigerating system in which all piping is made up of hard copper fittings and streamlined "wrought"-type fittings, the joints should be A) screwed B) soldered or brazed C) flanged with ground faces D) flanged with lined rubber gaskets - ANSWER -B) soldered or brazed If any piece of equipment can be isolated as a separate unit A) A gauge must be present B) a safety valve must be installed C) valves must be locked D) the system must be able to run without it - ANSWER -B) a safety valve must be installed On a 220 volt, three phase, 4-wire electric service, any line will read A) 220 volts B) 440 volts C) 70 volts D) 110 volts - ANSWER -D) 110 volts If the specific heat of glass is .196, how many btu are needed to raise the temperature of 10 pounds of glass from 50° F to 70°F? A) 40.2 B) 39.2 C) 59.2 D) 36.2 - ANSWER -B) 39.2 A direct expansion (bare) coil evaporator is used to maintain a meat storage space at 28 to 30° F. The last coil has no frost. It can be said that this system is A) condition is acceptable to maintain a high plant efficiency B) is a direct indication of air in the system C) indicates moisture in the refrigerant D) is a direct indication that the coil is being starved - ANSWER -D) is a direct indication that the coil is being starved Fuses and circuit breakers are safety devices for electric motors but they will not protect motors against A) short circuit B) heavy overload C) burnout D) overheating - ANSWER -D) overheating Sodium chloride is not used when the temperature is A) -20° F B) 10° F C) 5° F D) 0° F - ANSWER -A) -20° F The speed of a six-pole, 50-cycle motor is A) 600 RPM B) 1000 RPM C) 1800 RPM D) 3600 RPM - ANSWER -B) 1000 RPM The rated discharge capacity of the pressure-relief device or fusible plug for a refrigerant-containing vessel is determined by the formula C = Fd1. "C" equals A) btu/minute B) refrigerant pressure C) air in pounds/minute D) cubic feet/minute - ANSWER -C) air in pounds/minute In an automatically operated, flooded shell-and-tube cooler, an electric float switch is used primarily to A) control the flow of brine into the tubes B) control the flow of refrigerant into the shell C) purge the oil from the cooler D) purge non-condensable gas from the cooler - ANSWER -B) control the flow of refrigerant into the shell What are three reasons why compressors short cycle? - ANSWER -1. Leaky solenoid valve 2. Dirty or iced evaporator 3. Lack of refrigerant Find the volume of a cylinder 8" in diameter with a 10" stroke. How much water can be put in this cylinder? - ANSWER -V = πR2 x L V = 3.14 x 42 x 10 V = 3.14 x 16 x 10 V = 3.14 x 160 V = 502.4 cubic inches In order to vary the specific capacity of an absorption refrigerating plant, an operating engineer should regulate the A) Flow of steam to the generator, and adjust the expansion valve. B) Relief valves on the generator, and the speed of the NH2 pump. C) Speed of the absorber pump. D) Flow of water to the condenser. - ANSWER -A) Flow of steam to the generator, and adjust the expansion valve. The refrigerant least miscible in oil is A) CO2 B) R-12 C) R-40 D) R-141 - ANSWER -A) CO2 The first sign that the drum of ammonia refrigerant is almost empty is

Mostrar más Leer menos
Institución
Q-01 FDNY
Grado
Q-01 FDNY










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Q-01 FDNY
Grado
Q-01 FDNY

Información del documento

Subido en
7 de noviembre de 2025
Número de páginas
28
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Q-01 FDNY Exam – Questions and
Answers |Verified 100% Correct|

One characteristic of a synchronous motor is that it operates at
A) high starting torque
B) constant speed
C) causes lagging power factor
D) all of the above - ANSWER -B) constant speed

If during does not occur in a refrigerating system, what is the result?
A) High-head pressure
B) Low-condenser pressure
C) Low-head pressure
D) None of the above - ANSWER -A) High-head pressure

A wound-rotor induction motor with external resistance is a
A) multispeed motor
B) constant-speed motor
C) single-speed motor
D) waterproof cover - ANSWER -A) multispeed motor

In a Freon refrigerating system in which all piping is made up of hard copper
fittings and streamlined "wrought"-type fittings, the joints should be
A) screwed
B) soldered or brazed
C) flanged with ground faces
D) flanged with lined rubber gaskets - ANSWER -B) soldered or brazed

If any piece of equipment can be isolated as a separate unit
A) A gauge must be present
B) a safety valve must be installed
C) valves must be locked
D) the system must be able to run without it - ANSWER -B) a safety valve must be
installed

On a 220 volt, three phase, 4-wire electric service, any line will read
A) 220 volts

,B) 440 volts
C) 70 volts
D) 110 volts - ANSWER -D) 110 volts

If the specific heat of glass is .196, how many btu are needed to raise the
temperature of 10 pounds of glass from 50° F to 70°F?
A) 40.2
B) 39.2
C) 59.2
D) 36.2 - ANSWER -B) 39.2

A direct expansion (bare) coil evaporator is used to maintain a meat storage space
at 28 to 30° F. The last coil has no frost. It can be said that this system is
A) condition is acceptable to maintain a high plant efficiency
B) is a direct indication of air in the system
C) indicates moisture in the refrigerant
D) is a direct indication that the coil is being starved - ANSWER -D) is a direct
indication that the coil is being starved

Fuses and circuit breakers are safety devices for electric motors but they will not
protect motors against
A) short circuit
B) heavy overload
C) burnout
D) overheating - ANSWER -D) overheating

Sodium chloride is not used when the temperature is
A) -20° F
B) 10° F
C) 5° F
D) 0° F - ANSWER -A) -20° F

The speed of a six-pole, 50-cycle motor is
A) 600 RPM
B) 1000 RPM
C) 1800 RPM
D) 3600 RPM - ANSWER -B) 1000 RPM

The rated discharge capacity of the pressure-relief device or fusible plug for a
refrigerant-containing vessel is determined by the formula C = Fd1. "C" equals

, A) btu/minute
B) refrigerant pressure
C) air in pounds/minute
D) cubic feet/minute - ANSWER -C) air in pounds/minute

In an automatically operated, flooded shell-and-tube cooler, an electric float
switch is used primarily to
A) control the flow of brine into the tubes
B) control the flow of refrigerant into the shell
C) purge the oil from the cooler
D) purge non-condensable gas from the cooler - ANSWER -B) control the flow of
refrigerant into the shell

What are three reasons why compressors short cycle? - ANSWER -1. Leaky
solenoid valve
2. Dirty or iced evaporator
3. Lack of refrigerant

Find the volume of a cylinder 8" in diameter with a 10" stroke. How much water
can be put in this cylinder? - ANSWER -V = πR2 x L
V = 3.14 x 42 x 10
V = 3.14 x 16 x 10
V = 3.14 x 160
V = 502.4 cubic inches

In order to vary the specific capacity of an absorption refrigerating plant, an
operating engineer should regulate the
A) Flow of steam to the generator, and adjust the expansion valve.
B) Relief valves on the generator, and the speed of the NH2 pump.
C) Speed of the absorber pump.
D) Flow of water to the condenser. - ANSWER -A) Flow of steam to the generator,
and adjust the expansion valve.

The refrigerant least miscible in oil is
A) CO2
B) R-12
C) R-40
D) R-141 - ANSWER -A) CO2

The first sign that the drum of ammonia refrigerant is almost empty is
$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
TopGradeGuru
1.5
(2)

Conoce al vendedor

Seller avatar
TopGradeGuru Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
10
Miembro desde
1 año
Número de seguidores
0
Documentos
2429
Última venta
1 mes hace
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it's the go-to resource for exam preparation and academic success.

1.5

2 reseñas

5
0
4
0
3
0
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes