100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NACE CIP Level 1 Exam 2025: 250 Questions & Detailed Answers | Complete Study Guide

Puntuación
-
Vendido
-
Páginas
20
Grado
A
Subido en
04-11-2025
Escrito en
2025/2026

Prepare for the NACE CIP Level 1 Exam with the newest 2025 study guide. Includes 250 verified questions and detailed answers to help you pass with an A+ grade.

Institución
NACE CIP LEVEL 1
Grado
NACE CIP LEVEL 1










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NACE CIP LEVEL 1
Grado
NACE CIP LEVEL 1

Información del documento

Subido en
4 de noviembre de 2025
Número de páginas
20
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NACE CIP LEVEL 1 EXAM
NEWEST 2025 COMPLETE
250 QUESTIONS AND
ANSWERS GRADED A+
[Document subtitle]




[DATE]
[COMPANY NAME]
[Company address]

,1. Dew point is the temperature at which:
Condensation occurs.

2. You are the NACE Inspector on a tank lining project where a 50% solids
epoxy tank lining is being applied. After application of the 19 coat you notice
small blisters in some areas of the applied lining. Your FIRST preferred
course of action is to:
Document the problem and advise the Contractor and Owner's representative.

3. If a contractor is using a poorly maintained compressor to supply air for
abrasive blast cleaning and conventional airspray, the coating inspector
should perform a:
Blotter test for the presence of oil and water.

4. Upon arrival of coating materials, the inspector should:
Observe and document the amount of material and batch numbers.

5. Relative humidity is:
A measure of the amount of moisture in the air compared to saturation level.

6. Galvanic corrosion occurs on which of the following substrates?
Metal.

7. When applying Thermal Spray Coatings the specification is most likely to
reference:
SSPC-CS 23.00/AWS C2.23/NACE No. 12.

8. What is the minimum recommended distance away from an edge that an
inspector should take a measurement with a dial type magnetic pull off Dry
Film Thickness (DFT) gauge?
2.5 cm (1 inch).

9. Polymerization is the process of?
Monomers joining together.

10. An exposed area of the substrate or previous coat of a conductive material,
often caused by poor application technique is called:
Holiday.

11. Checking is:
A fine crack in the surface of a coating that rarely reaches the substrate.

12. Inspection documentation is important because:
Owners use the documentation for a variety of purposes.

13. An Inspector's personal log book should contain:
No comments regarding the application team.

, 14. You have just received your NACE CIP Level 1 certification when you are
asked to supervise a team of uncertified field pipeline inspectors. Your FIRST
preferred course of action is to:
Review the NACE Attestation prior to making a decision.

15. Good records can provide maintenance departments with detailed
information about ALL of the following EXCEPT:
How the item was coated.

16. Non-Conformance Reports are completed by the Inspector:
When the Inspector and Contractor deem it to be a significant non-conforming
item.

17. The initial steel condition is important to the NACE Inspector because:
The Inspector may have to reject the steel.

18. The form of corrosion that has the largest potential for unexpected
catastrophic failure is:
Galvanic Corrosion.

19. What is used to determine compressed air cleanliness?
Profilometer.

20. Osmotic blistering is most likely to occur as a result of:
Airless spray application.

21. When performing tests for oil and grease using an ultraviolet light, the NACE
Inspector should be aware that:
Synthetic oil or grease may not be identified.

22. To achieve consistently accurate results with ALL test equipment:
Wash your hands before sampling.

23. When holiday testing is required the Inspector is always required to enforce
what standard?
NACE SP 0188.

24. If the specifier does not identify a restriction level in accordance with SSPC
PA 2, the default restriction level is:
Level 3.

25. Fine cracks in the surface of a coating that rarely reach the substrate are
called:
Checking.
$13.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
skylersammuels

Conoce al vendedor

Seller avatar
skylersammuels Rasmussen College
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
3 meses
Número de seguidores
0
Documentos
278
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes