100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NICET Level 1 – Water-Based Layout Practice Questions and Answers | 100% Pass Guarantee

Puntuación
-
Vendido
-
Páginas
19
Grado
A+
Subido en
01-11-2025
Escrito en
2024/2025

This document provides the complete collection of verified practice questions and answers for the NICET Level 1 Water-Based Layout Exam. It covers all essential topics, including sprinkler system components, layout design, hydraulic calculations, codes and standards (NFPA 13), and safety procedures. Perfect for entry-level technicians and professionals preparing for NICET certification, this guide ensures thorough understanding and a guaranteed pass on the first attempt.

Mostrar más Leer menos
Institución
NICET Level 1 –
Grado
NICET Level 1 –










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NICET Level 1 –
Grado
NICET Level 1 –

Información del documento

Subido en
1 de noviembre de 2025
Número de páginas
19
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Vista previa del contenido

NICET Level 1 – Water-Based Layout Practice
Questions and Answers | 100% Pass Guarantee



Section 1: NFPA 13 Standards (Questions 1-14)
This section covers general requirements, definitions, and system types per NFPA 13 Chapter 4
(General Requirements) and Chapter 5 (Classification of Occupancies).

1. What is the minimum discharge density for Light Hazard occupancies under NFPA 13?
a) 0.10 gpm/ft²
b) 0.15 gpm/ft²
c) 0.25 gpm/ft²

d) 0.30 gpm/ft²

Correct Answer: b) 0.15 gpm/ft²

Rationale: Light Hazard requires a minimum density of 0.15 gpm/ft² over the remote area.
(NFPA 13 Section 5.2)

2. Calculate the remote area for a wet system in an Ordinary Hazard Group 2 occupancy
with a ceiling height of 20 ft.
a) 1300 ft²
b) 1500 ft²
c) 1650 ft²

d) 1950 ft²

Correct Answer: c) 1650 ft²

Rationale: Base area 1500 ft², increased 10% for ceiling height >10 ft (1% per foot over 10 ft:
10% = 150 ft²). (NFPA 13 Section 27.2.4.2)

3. For dry systems, what is the maximum system volume without quick-opening devices?
a) 500 gal
b) 750 gal
c) 1000 gal

d) 1500 gal

,Correct Answer: b) 750 gal

Rationale: Dry systems limited to 750 gal unless quick-opening devices are used. (NFPA 13
Section 8.2.3.1)

4. What occupancy class includes woodworking shops with moderate combustibles?
a) Light Hazard
b) Ordinary Hazard Group 1
c) Ordinary Hazard Group 2

d) Extra Hazard Group 1

Correct Answer: c) Ordinary Hazard Group 2

Rationale: OH2 for moderate to high combustibility like woodworking. (NFPA 13 Section 5.3.2)

5. In a preaction system, what activates the deluge valve?
a) Heat detection
b) Manual pull
c) Both a and b

d) Water flow only

Correct Answer: c) Both a and b

Rationale: Preaction requires detection (heat/smoke) or manual activation before water release.
(NFPA 13 Section 8.3.1)

6. Calculate the discharge for a K-8 sprinkler at 7 psi.
a) 16.8 gpm
b) 21.2 gpm
c) 23.7 gpm

d) 28.3 gpm

Correct Answer: b) 21.2 gpm

Rationale: Q = K √P = 8 × √7 ≈ 21.2 gpm. (NFPA 13 Section 6.4.1)

7. What is the minimum pipe slope for wet systems?
a) 1/8 in./ft
b) 1/4 in./ft
c) 1/2 in./ft

d) No slope required

Correct Answer: b) 1/4 in./ft

, Rationale: To prevent water pockets; 1/4 in./ft for branches. (NFPA 13 Section 8.16.2.2)

8. For ESFR sprinklers, what is the maximum ceiling height without in-rack?
a) 30 ft
b) 40 ft
c) 45 ft

d) 50 ft

Correct Answer: c) 45 ft

Rationale: Updated in 2025 for high ceilings; ESFR up to 45 ft for certain commodities. (NFPA
13 Section 12.1.2.1)

9. What system type is required for freezer storage?
a) Wet
b) Dry
c) Preaction

d) Deluge

Correct Answer: b) Dry

Rationale: Dry systems prevent freezing in unheated areas. (NFPA 13 Section 8.4.1)

10. Calculate the area adjustment for a dry system remote area of 1500 ft².
a) 1500 ft²
b) 1950 ft²
c) 2250 ft²

d) 3000 ft²

Correct Answer: b) 1950 ft²

Rationale: 30% increase for dry systems: 1500 × 1.3 = 1950 ft². (NFPA 13 Section 27.2.4.4)

11. What is the K-factor for standard spray sprinklers?
a) 5.6
b) 8.0
c) 11.2

d) 14.0

Correct Answer: a) 5.6

Rationale: Standard orifice K=5.6 for upright/pendent. (NFPA 13 Section 6.2.3)
$12.29
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STUDYACEFILES (self)
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
26
Miembro desde
1 año
Número de seguidores
5
Documentos
903
Última venta
2 días hace
StuviaNurseVault

Welcome to StuviaNurseVault!

4.2

6 reseñas

5
2
4
3
3
1
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes