100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Limited Scope of Radiography Practice Exam UPDATED QUESTIONS AND CORRECT ANSWERS

Puntuación
-
Vendido
-
Páginas
23
Grado
A+
Subido en
30-10-2025
Escrito en
2025/2026

Limited Scope of Radiography Practice Exam UPDATED QUESTIONS AND CORRECT ANSWERS what statements are correct regarding the link between radiation and genetic effects - CORRECT ANSWER The link has been demonstrated in animal studies . Increased risk to humans cannot be predicted with respect to an individual. The changes in kilovoltage (kVp) will result in the greatest reduction of patient dose, when milliampere-seconds (mAs) is adjusted to compensate for the change - CORRECT ANSWER Increase kVp by 30% The following image receptor (IR) system speeds will result in the lowest patient dose - CORRECT ANSWER Faster speed IR system The primary purpose of using gonad shields - CORRECT ANSWER likelihood of genetic effects Are gonad shields - CORRECT ANSWER Contact and shadow gonad shielding should be used - CORRECT ANSWER reduce the when the gonads are within 5 cm of the radiation field the greatest cause of unnecessary radiation to patients that can be controlled by the limited operator is - CORRECT ANSWER repeat exposures

Mostrar más Leer menos
Institución
Limited Scope Of Radiography
Grado
Limited Scope of Radiography










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Limited Scope of Radiography
Grado
Limited Scope of Radiography

Información del documento

Subido en
30 de octubre de 2025
Número de páginas
23
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Limited Scope of Radiography Practice
Exam UPDATED QUESTIONS AND
CORRECT ANSWERS
what statements are correct regarding the link between radiation and genetic effects -
CORRECT ANSWER The link has been demonstrated in animal studies .

Increased risk to humans cannot be predicted with respect to an individual.



The changes in kilovoltage (kVp) will result in the greatest reduction of patient dose, when
milliampere-seconds (mAs) is adjusted to compensate for the change - CORRECT
ANSWER Increase kVp by 30%



The following image receptor (IR) system speeds will result in the lowest patient dose -
CORRECT ANSWER Faster speed IR system



The primary purpose of using gonad shields - CORRECT ANSWER reduce the
likelihood of genetic effects



Are gonad shields - CORRECT ANSWER Contact and shadow



gonad shielding should be used - CORRECT ANSWER when the gonads are within 5
cm of the radiation field


the greatest cause of unnecessary radiation to patients that can be controlled by the limited
operator is - CORRECT ANSWER repeat exposures



the limited operator can reduce repeat exposure - CORRECT ANSWER clearly
instructing patients


how does the x-ray beam restriction minimize patient exposure - CORRECT
ANSWER it limits the radiation field to the area of interest

,what is the device that allows the limited operator to vary the size of the radiation field -
CORRECT ANSWER collimator



how does filtration reduce patient exposure - CORRECT ANSWER removes longer-
wavelength photons


The National Council on Radiation Protection and Measurements(NCRP) recommendation
for the amount of total filtration - CORRECT ANSWER 2.5 mm Al equiv



Three principal methods used to protect limited operators from unnecessary radiation
exposure - CORRECT ANSWER time, distance, and shielding



The following is not a type of personal radiation shielding - CORRECT
ANSWER Shadow



personnel shielding must be worn on the rare occasion during which the limited operator may
need to remain in the radiographic room during an exposure to assist the patient in
maintaining the proper position. What is the source of the greatest radiation hazard under this
circumstance.? - CORRECT ANSWER scattered radiation from the patient



the term for radiation the escapes from the x-ray tube housing - CORRECT
ANSWER leakage radiation



why are limited operators prohibited from activities that result in direct exposure to the
primary x-ray beam - CORRECT ANSWER they are considered occupationally
exposed individuals



distance, as a method used to limit operator exposure, means that - CORRECT
ANSWER the operator should maximize the distance from the source during an
exposure

, shielding worn for personnel protection is designed to attenuate what source of exposure -
CORRECT ANSWER scatter radiation



the acronym for a common type of personnel dosimeter - CORRECT ANSWER TLD



What is the recommended placement for personnel dosimeter on the body of the limited
operator - CORRECT ANSWER the badge should be worn in the region of the collar
on the anterior surface of the body and outside the lead apron, if worn


The NCRP recommended annual effective dose limit for occupational exposure - CORRECT
ANSWER 5.0 rem (0.05 Sv)



The NCRP recommended monthly effective (or equivalent) dose limit to the fetus for a
pregnant worker - CORRECT ANSWER 0.05 rem (0.0005 Sv)



Radiation monitoring of personnel is required when what percentage of the annual
occupational effective dose limit is likely to be received - CORRECT ANSWER 10%



The conventional (British system) radiation unit to express radiation intensity in the air -
CORRECT ANSWER Roentgen



The conventional (British system) unit commonly used to report occupational dose to
radiation workers in the United States is the - CORRECT ANSWER rem



What is the conventional (British system) radiation unit of absorbed dose - CORRECT
ANSWER Rad



According to the Bergonie-Tribondeau law, the following types of cells are most
radiosensitive - CORRECT ANSWER embryonic tissue cells



Type of x-ray photon interaction with the body is primarily responsible for the radiation dose
absorbed by the patient - CORRECT ANSWER Photoelectric
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STANFORDTOPGRADES Stanford University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
23
Miembro desde
9 meses
Número de seguidores
2
Documentos
4593
Última venta
1 semana hace
TOPSELLER

Hi there! I'm dedicated to sharing my high-quality study guides and helpful EXAM Materials to make your learning easier and more efficient. All my materials are well-organized and tailored to help you ace your courses. I offer genuine and dependable exam papers that are directly obtained from well-known, reputable institutions as a highly regarded professional who specializes in sourcing study materials. Kindly don't hesitate to contact me, my study guides, notes and exams or test banks, are 100% graded and fully guaranteed

Lee mas Leer menos
4.7

3 reseñas

5
2
4
1
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes