100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

ASSE Backflow Recertification Practice Test With Complete Questions and Correct Answers | Graded A+ | Verified Answers And Brand New ASSE Backflow Recertification Practice Test

Puntuación
-
Vendido
-
Páginas
21
Grado
A+
Subido en
27-10-2025
Escrito en
2025/2026

ASSE Backflow Recertification Practice Test With Complete Questions and Correct Answers | Graded A+ | Verified Answers And Brand New

Institución
ASSE Backflow Recertification
Grado
ASSE Backflow Recertification










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ASSE Backflow Recertification
Grado
ASSE Backflow Recertification

Información del documento

Subido en
27 de octubre de 2025
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ASSE Backflow Recertification Practice Test 2025-
2026 With Complete Questions and Correct
Answers | Graded A+ | Verified Answers And
Brand New
A check valve in an approved backflow assembly must be tight when -
answer--The assembly is subject to any backflow


a leaking check valve may be caused by? - answer--Dirty or damaged
check disc, damaged check seat, broken or damaged spring, guide
members hanging up (all of the above)


Test cock number one of an approved double check valve assembly is
located - answer--Upstream on shutoff valve number one


On an approved pressure vacuum breaker assembly, the shut off valves
- answer--Are located at the inlet and outlet of all assemblies


The bypass line of a backflow must contain an approved assembly of
equal - answer--Temperature rating


The bypass line of a backflow must contain an approved assembly of
equal - answer--Protection

,An atmospheric pressure vacuum breaker shall not be subjected to
water pressure for more than _______ hours - answer--12


It is possible for a perfect vacuum at sea level to raise water in a pipe
approximately ____ feet? - answer--34 feet


What is the most desirable place install a Backflow? - answer--In an
accessible location above ground


Which of the following conditions could result in water contamination
through cross connection? - answer--Turning off service to a multi story
building and allowing water supply to drain


The degree of hazard is - answer--BASED UPON THE QUALITY OF A NON
POTABLE WATER SOURCE


The minimum type of containment protection for a non-health hazard,
non chemical sprinkler is - answer--Double check


Type of protection required for a closed loop heating system containing
chemicals - answer--RPZ

, Water continuously leaking from test cock #2 during a test procedure of
a pressure vacuum breaker assembly is probably caused by a leaking -
answer--INLET SHUT-OFF VALVE #1


The required backflow for a fire sprinkler system containing chemicals is
- answer--RPZ


Required protection of a backflow for a closed loop system containing
glycol is - answer--RPZ


Primary consideration in determining what type of backflow to install is
- answer--Degree of hazard


What is the probable cause of a relief valve failing to open during a field
test of a RPZ? - answer--Malfunction of the relief valve mechanism


The required backflow protection for a chemically charged solar heating
system with an expansion tank is? - answer--RPZ


Type of protection associated with an air gap separation is - answer--
Backsiphonage & back pressure ( all of the above)
$25.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
muiajanet932

Conoce al vendedor

Seller avatar
muiajanet932 Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
4 meses
Número de seguidores
0
Documentos
295
Última venta
4 meses hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes