__________ are the most cost-effective and efficient method of protecting property
from fire
Ans: Automatic sprinklers
A/the __________ is a nongovernmental agency that has been approved by the code
official to conduct tests and inspections; test and inspection results are forwarded to a
code official, who approves or rejects the installation, construction, or operation.
Ans: third-party agency
Built-in fire protection features, or fire resistance-rated construction, that provide fire
safety and do not require activation are:
Ans: passive fire protection features.
__________ contribute to public apathy and the potential for significant danger.
Ans: False alarms
__________ is/are the leading cause of sprinkler failure.
Ans: Closed valves
__________ is a user-friendly document that includes maintenance provisions; test
protocols; and schedules that summarize weekly, monthly, and annual tests for nearly
all water-based fire protection systems.
© Get it right 2025 Getaway - Stuvia US All rights reserved
,Click here for more: Scholars nexus
Ans: NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based
Fire Protection Systems
Most __________ want timely inspection service, to know what is expected of them,
and to be informed of the cost at the start of the project.
Ans: developers
Outside screw and yoke valves and post indicator valves for sprinkler water supplies
were designed to be instantly recognized as:
Ans: open and shut.
Passive fire protection features may malfunction due to all of the following EXCEPT:
Ans: faulty activation.
__________ such as automatic sprinklers, fire detectors, or smoke removal systems
operate or activate automatically or manually.
Ans: Active fire protection features
Test records must be available __________ for inspectors to examine.
Ans: on site
The chances of dying in a fire are cut by one-half to two-thirds in __________
buildings.
Ans: sprinklered
The first active fire protection systems in buildings were the result of:
© Get it right 2025 Getaway - Stuvia US All rights reserved
,Click here for more: Scholars nexus
Ans: insurance company requirements.
The involvement of __________ in the inspection of new fire protection systems is a
fairly recent development.
Ans: fire departments
The __________ is responsible for the physical performance of active fire protection
systems tests and conformance with the code.
Ans: installing contractor
The reliability of active fire protection features depends on all of the following
elements EXCEPT:
Ans: cost.
"What agency has oversight responsibility of fire protection systems?", "How many
and what type of systems are installed each year?", and "Is the fire department willing
to provide personnel, training, and resources to adequately perform the job?" are all
questions one should ask when developing a(n):
Ans: acceptance testing program.
Which of the following would rarely require sprinklers based on occupancy
classification?
Ans: Office buildings
Witnessing of acceptance tests by fire department personnel does all of the following
EXCEPT:
© Get it right 2025 Getaway - Stuvia US All rights reserved
, Click here for more: Scholars nexus
Ans: restrict training for fire fighters in the design and operation of the fire protection
system.
You are writing a paper on the inspection, testing, and maintenance of sprinkler
systems and would like to reference some test protocols, schedules, and checklist
summaries. Which document would be most useful?
Ans: NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based
Fire Protection Systems
An administrative warrant issued by a court with jurisdiction commanding an officer
to inspect a specific premise is a(n):
Ans: inspection warrant.
A(n) __________ clause is a clause within the model fire codes that authorizes the
fire official to enter buildings and premises with the permission of the occupant for the
purpose of enforcing the code.
Ans: right of entry
A(n) __________ is an occupancy that houses persons whose capacity for self-
preservation is limited or diminished by reason of age, infirmity, or confinement.
Ans: institutional occupancy
__________ are permanent or temporary structures that provide a walkway or
method of transportation wherein the required means of egress is not apparent or is
confounded through the use of theatrical or special effects.
Ans: Special amusement buildings
© Get it right 2025 Getaway - Stuvia US All rights reserved
Fire Prevention Questions with Detailed Verified
Answers
__________ are the most cost-effective and efficient method of protecting property
from fire
Ans: Automatic sprinklers
A/the __________ is a nongovernmental agency that has been approved by the code
official to conduct tests and inspections; test and inspection results are forwarded to a
code official, who approves or rejects the installation, construction, or operation.
Ans: third-party agency
Built-in fire protection features, or fire resistance-rated construction, that provide fire
safety and do not require activation are:
Ans: passive fire protection features.
__________ contribute to public apathy and the potential for significant danger.
Ans: False alarms
__________ is/are the leading cause of sprinkler failure.
Ans: Closed valves
__________ is a user-friendly document that includes maintenance provisions; test
protocols; and schedules that summarize weekly, monthly, and annual tests for nearly
all water-based fire protection systems.
© Get it right 2025 Getaway - Stuvia US All rights reserved
,Click here for more: Scholars nexus
Ans: NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based
Fire Protection Systems
Most __________ want timely inspection service, to know what is expected of them,
and to be informed of the cost at the start of the project.
Ans: developers
Outside screw and yoke valves and post indicator valves for sprinkler water supplies
were designed to be instantly recognized as:
Ans: open and shut.
Passive fire protection features may malfunction due to all of the following EXCEPT:
Ans: faulty activation.
__________ such as automatic sprinklers, fire detectors, or smoke removal systems
operate or activate automatically or manually.
Ans: Active fire protection features
Test records must be available __________ for inspectors to examine.
Ans: on site
The chances of dying in a fire are cut by one-half to two-thirds in __________
buildings.
Ans: sprinklered
The first active fire protection systems in buildings were the result of:
© Get it right 2025 Getaway - Stuvia US All rights reserved
,Click here for more: Scholars nexus
Ans: insurance company requirements.
The involvement of __________ in the inspection of new fire protection systems is a
fairly recent development.
Ans: fire departments
The __________ is responsible for the physical performance of active fire protection
systems tests and conformance with the code.
Ans: installing contractor
The reliability of active fire protection features depends on all of the following
elements EXCEPT:
Ans: cost.
"What agency has oversight responsibility of fire protection systems?", "How many
and what type of systems are installed each year?", and "Is the fire department willing
to provide personnel, training, and resources to adequately perform the job?" are all
questions one should ask when developing a(n):
Ans: acceptance testing program.
Which of the following would rarely require sprinklers based on occupancy
classification?
Ans: Office buildings
Witnessing of acceptance tests by fire department personnel does all of the following
EXCEPT:
© Get it right 2025 Getaway - Stuvia US All rights reserved
, Click here for more: Scholars nexus
Ans: restrict training for fire fighters in the design and operation of the fire protection
system.
You are writing a paper on the inspection, testing, and maintenance of sprinkler
systems and would like to reference some test protocols, schedules, and checklist
summaries. Which document would be most useful?
Ans: NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based
Fire Protection Systems
An administrative warrant issued by a court with jurisdiction commanding an officer
to inspect a specific premise is a(n):
Ans: inspection warrant.
A(n) __________ clause is a clause within the model fire codes that authorizes the
fire official to enter buildings and premises with the permission of the occupant for the
purpose of enforcing the code.
Ans: right of entry
A(n) __________ is an occupancy that houses persons whose capacity for self-
preservation is limited or diminished by reason of age, infirmity, or confinement.
Ans: institutional occupancy
__________ are permanent or temporary structures that provide a walkway or
method of transportation wherein the required means of egress is not apparent or is
confounded through the use of theatrical or special effects.
Ans: Special amusement buildings