ASNT Magnetic Particle Level 3 Questions With Correct Answers ferromagnetic material A material that is strongly attracted to a magnetic field. Diamagnetic material A material that is repelled by a magnetic field paramagnetic slightly attracted to magnets Is Demagnetized When a ferromagnetic material reaches its Currie temperature the material is Alloy, shape, and condition of the part An important factor that must be considered when selecting a method of magnetization is the Fixed positions, predominantly in One Direction The magnetic domains in a permanent magnet are aligned in Diamagnetic Any material with a negative relative permeability that is slightly less than one is Casting Gas, hot tears, cold shuts, shrinkage cracks and sand inclusions are examples of defects resulting from which of the following processes? If the part is to be radiographed after magnetic particle inspection, residual magnetism may interfere with the electromagnetic radiation spectrum. Which of the following statements is NOT a valid reason for demagnetizing a part after completing a magnetic particle test Demagnetizes the part Subjecting a part to a magnetic field that is constantly reversing in polarity and gradually diminishing in strength accomplishes which of the following Permitting the solids to settle out of suspension The concentration of the solid content in suspension of magnetic particles is measured by The parts are painted Magnetic particle inspection methods on ferromagnetic materials are recognized as superior to liquid penetrant techniques when is slightly magnetic A paramagnetic material Move the alternating current coil farther away from the part Which of the following will reduce a magnetic field Coercive force When an external magnetizing force is removed, some of the magnetic domains remain preferentially oriented. The additional force required to return them to their original random orientation is commonly referred to as At the inside surface of the cylinder When is cylinder is magnetized by central conductor, the field is most intense While the magnetizing current is applied When is the magnetic field strongest in the object being inspected by the magnetic particle method? Direct current with reversing and step down control Which demagnetization technique is most effective? 3000 A When using a longitudinal magnetization technique to inspect a bar 152 mm (6in) bar and 51 mm (2in) in diameter with a 5 ton coil, what amperage value should be used? 3600 A To examine a part 127 mm (5in) long and 51 mm (2in) in diameter using a 5 turn coil and headstock magnetic particle machine, what amperage should be used for longitudinal magnetization? 1800 A To examine a bar 381 mm (15in) long and 51 mm (2in) in diameter, what amperage should be used on a stationary magnetic particle machine to create a direct circular magnetic field? Of the 25 mm (1") bar will be approximately twice that of the 51 mm (2") bar If the same amperage is passed through a 25 mm and 51 mm (1 inch and 2 inch) diameter bar of the same length and material, the strength of the magnetic field at the surface Both bars will be 0 If the same amperage is passed through a 25 mm (1 inch) diameter bar and a 51 mm (2 inch) diameter bar of the same length and material, the strength of the magnetic field at the center of Circular field When a magnetic field is induced in a part with prods spaced 152 mm (6") apart, the field is a The skin effect of alternating current reduces the maximum depth at which discontinues can be found When circular magnetization is used to detect subsurface discontinuities, direct current is used instead of alternating current because Serge technique An inspection technique in which an initial magnetization force is applied to a part and then reduced to a lower continuous value is called the The retentivity of a part When deciding to inspect a part by the residual technique of applying the particles, what factor affects the residual magnetic field strength of the part Orientation and shape of the indication and the direction of the magnetic field Factors that must be considered when interpreting an indication are the 6.0

Mostrar más Leer menos
Institución
Asnt Level 3
Grado
Asnt level 3











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Asnt level 3
Grado
Asnt level 3

Información del documento

Subido en
24 de octubre de 2025
Número de páginas
31
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ASNT Magnetic Particle Level 3
Questions With Correct Answers



ferromagnetic material

A material that is strongly attracted to a magnetic field.

Diamagnetic material

A material that is repelled by a magnetic field

paramagnetic

slightly attracted to magnets

Is Demagnetized

When a ferromagnetic material reaches its Currie temperature the material is

Alloy, shape, and condition of the part

An important factor that must be considered when selecting a method of magnetization is the

Fixed positions, predominantly in One Direction

The magnetic domains in a permanent magnet are aligned in

Diamagnetic

Any material with a negative relative permeability that is slightly less than one is

Casting

Gas, hot tears, cold shuts, shrinkage cracks and sand inclusions are examples of defects resulting
from which of the following processes?

If the part is to be radiographed after magnetic particle inspection, residual magnetism may
interfere with the electromagnetic radiation spectrum.

Which of the following statements is NOT a valid reason for demagnetizing a part after
completing a magnetic particle test

,Demagnetizes the part

Subjecting a part to a magnetic field that is constantly reversing in polarity and gradually
diminishing in strength accomplishes which of the following

Permitting the solids to settle out of suspension

The concentration of the solid content in suspension of magnetic particles is measured by

The parts are painted

Magnetic particle inspection methods on ferromagnetic materials are recognized as superior to
liquid penetrant techniques when

is slightly magnetic

A paramagnetic material

Move the alternating current coil farther away from the part

Which of the following will reduce a magnetic field

Coercive force

When an external magnetizing force is removed, some of the magnetic domains remain
preferentially oriented. The additional force required to return them to their original random
orientation is commonly referred to as

At the inside surface of the cylinder

When is cylinder is magnetized by central conductor, the field is most intense

While the magnetizing current is applied

When is the magnetic field strongest in the object being inspected by the magnetic particle
method?

Direct current with reversing and step down control

Which demagnetization technique is most effective?

3000 A

When using a longitudinal magnetization technique to inspect a bar 152 mm (6in) bar and 51
mm (2in) in diameter with a 5 ton coil, what amperage value should be used?

3600 A

,To examine a part 127 mm (5in) long and 51 mm (2in) in diameter using a 5 turn coil and
headstock magnetic particle machine, what amperage should be used for longitudinal
magnetization?

1800 A

To examine a bar 381 mm (15in) long and 51 mm (2in) in diameter, what amperage should be
used on a stationary magnetic particle machine to create a direct circular magnetic field?

Of the 25 mm (1") bar will be approximately twice that of the 51 mm (2") bar

If the same amperage is passed through a 25 mm and 51 mm (1 inch and 2 inch) diameter bar
of the same length and material, the strength of the magnetic field at the surface

Both bars will be 0

If the same amperage is passed through a 25 mm (1 inch) diameter bar and a 51 mm (2 inch)
diameter bar of the same length and material, the strength of the magnetic field at the center
of

Circular field

When a magnetic field is induced in a part with prods spaced 152 mm (6") apart, the field is a

The skin effect of alternating current reduces the maximum depth at which discontinues can
be found

When circular magnetization is used to detect subsurface discontinuities, direct current is used
instead of alternating current because

Serge technique

An inspection technique in which an initial magnetization force is applied to a part and then
reduced to a lower continuous value is called the

The retentivity of a part

When deciding to inspect a part by the residual technique of applying the particles, what factor
affects the residual magnetic field strength of the part

Orientation and shape of the indication and the direction of the magnetic field

Factors that must be considered when interpreting an indication are the

6.0

, A 7 turn coil at 1000 A is used to inspect a round solid part 381 mm (15 inches) long and 64 mm
(2.5 inches) in diameter. The length to diameter ratio is

Longitudinal magnetization

When used as the last magnetizing technique, will best render a part suitable for a relatively
easy measurement of the external magnetic field using a field indicator?

Reinspect using alternating current

When using direct current an indication is detected. What is the next logical step to determine if
the indication results from a surface to subsurface condition?

Advantageous

With dry particles, particle mobility is

Cost of the equipment

The least important factor that should be considered when selecting a technique for
magnetization to detect subsurface discontinuities is

Laminations

Discontinuities that occur as a result of the rolling process

Laps

Discontinuities that occur as a result of the forging process

Is the highest while the current is being applied

The continuous technique provides the most sensitivity because flux density

Furring

Is not considered a surface coating that can affect the sensitivity of magnetic particle testing?

Enter the south pole and leave the north pole

The magnetic lines of flux in a permanent magnet

Parallel magnetization

Which of the following magnetization techniques is NOT recommended for magnetic particle
testing

Establish a longitudinal field and then proceed with demagnetization
$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
IszackBd

Documento también disponible en un lote

Thumbnail
Package deal
ASNT LEVEL 3 EXAMS PACKAGE
-
5 2025
$ 76.45 Más información

Conoce al vendedor

Seller avatar
IszackBd University Of Washington
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
1 año
Número de seguidores
0
Documentos
1852
Última venta
2 meses hace
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Lee mas Leer menos
0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes