Section 1: Laboratory Safety and Procedures
1. What is the primary purpose of a Safety Data Sheet (SDS)? - ANSWER ✓ To
provide detailed information on the hazards of a chemical, along with safe handling,
storage, and emergency measures.
2. What type of fire extinguisher is used for electrical fires? - ANSWER ✓ Class C
fire extinguisher.
3. What is the correct first-aid response for a chemical splash to the eyes? -
ANSWER ✓ Immediately flush the eyes at an emergency eyewash station for at least 15
minutes and seek medical attention.
4. What personal protective equipment (PPE) is mandatory for most lab
procedures? - ANSWER ✓ Safety glasses, lab coat, and gloves.
5. Why is it forbidden to store food or drinks in a laboratory refrigerator? -
ANSWER ✓ To prevent chemical contamination and accidental ingestion of hazardous
substances.
6. What is the proper way to dispose of a broken glass beaker that contained a
non-hazardous solution? - ANSWER ✓ Place it in a dedicated, puncture-resistant
"sharps" or broken glass disposal container.
7. How should you dilute a concentrated acid with water? - ANSWER ✓ Always add
acid to water slowly while stirring ("Do as you oughta, add acid to wata").
8. What does the term "QA/QC" stand for in the laboratory context? - ANSWER
✓ Quality Assurance and Quality Control.
, 9. What is the purpose of a Method Detection Limit (MDL) study? - ANSWER ✓ To
determine the minimum concentration of an analyte that can be detected with 99%
confidence.
10. What is the difference between a precision check and an accuracy check? -
ANSWER ✓ Precision checks the reproducibility of results (e.g., duplicates), while
accuracy checks how close a result is to the true value (e.g., using a standard reference
material).
Section 2: Sample Collection and Preservation
11. What is a composite sample? - ANSWER ✓ A sample formed by combining
multiple discrete samples collected at regular intervals over a specific time period.
12. What is a grab sample? - ANSWER ✓ A single sample collected at a specific time
and place, representing conditions only at that moment.
13. Why is it crucial to measure and record pH and temperature immediately upon
sample collection? - ANSWER ✓ Because they are unstable parameters that can
change quickly due to exposure to air or temperature shifts.
14. For a BOD sample, what preservation method is used? - ANSWER
✓ Refrigeration at 4°C, and it should be analyzed within 48 hours of collection.
15. Why is nitric acid added to a sample intended for metal analysis? - ANSWER
✓ To acidify the sample, which keeps metals dissolved in solution and prevents them
from adsorbing to the container walls.
16. What does "Headspace" in a sample bottle refer to, and why is it important? -
ANSWER ✓ It is the air space between the sample and the cap. Minimizing headspace is
critical for volatile analytes to prevent loss or pressure buildup.
17. What is the typical maximum holding time for a preserved Total Suspended
Solids (TSS) sample? - ANSWER ✓ 7 days.
18. Why must sample bottles for bacteriological testing be sterile? - ANSWER ✓ To
prevent contamination from external microorganisms that would skew the results.