Defect in protective coating and the waterproofing coating of insulation will permit
moisture to come into contact with piping. To inspect for CUI, sections of insulation
should be removed from: - Answer-Small connection, such as bleed lines and gauge
connections.

Several locally thinned areas have been found during an inspection. What is a true
statement concerning the first step in ant corrective action? - Answer-A piping engineer
should evaluate the locally thinned area.

What does not describe a common type of flange used in piping? - Answer-574 4.5.1
Threaded socket

How often shall ultrasonic equipment be checked for calibration? - Answer-Section V T-
534 At the beginning of each examination and any time malfunctioning equipment is
noted.

What is NOT an example of environmental cracking? - Answer-Low temperature SCC

SCC: Stress corrosion cracking

P number 1 and 3 are welded together for a procedure qualification, this combination
will not allow the writing of a WPS or WPS's to be used to wield the following parent
metals in production: - Answer-Section IX QW-424
P #1 to P #3

Unless otherwise specified by the engineering design, the following records shall be
retained after the record is generated for a piping project. Examination procedures and
examination personnel qualification. For how long must they be retained after the
project is complete? - Answer-5 Years

For calculating the MAWP of system in service made of an unknown material the
following approach must be taken. - Answer-Computations may be made assuming the
lowest grade material and joint efficiency in the applicable code
Part of the definition of cold spring as used with piping is: - Answer-The intentional
deformation of piping to produce a desired effect

Threaded joints can be used where: - Answer-Severe corrosion is not expected

What is safe guarding a piping system? - Answer-A provision for extra protective
measures

, The following charpy impact results where obtained on a piping material with a required
minimum average of 13 Ft-LBF, and a minimum value for a single specimen is 10 FT-
LBF. The result were 16, 17, and 12 LB-F. What is a true statement about the test
results? - Answer-The Results pass the acceptance criteria of B31.3

A flanged joint is composed of three separate and independent, although interrelated
components: The flanges, the gaskets, and the bolting, which are affected by yet
another influence. What is the influence? - Answer-The Assembler

Underground piping is usually given above grade visual surveillance by: - Answer-An
inspection at and just below the point where it enters the earth, asphalt, or concrete.

Concering radiography of the following, what is not an advantage? - Answer-It is
excellent at finding flaws in plastic piping welds.

Steel and alloy piping are manufactured to standard dimensions in the nominal pipe size
up to: - Answer-48 inches

The following is not a true statement about the scope of API 570 - Answer-Only metal
piping may be inspected by the rules of API 570 code.

What type of on-stream welded repair is not permitted by API 570? - Answer-570
8.1.3.1
Square fillet welded patches without rounded corners

Before any method of inspection is adopted for piping what should be checked? -
Answer-574 5.4
Regulatory Requirements

What is the temperature limit of an EFC inflatable transducer ring? - Answer-10 degree
C (160 degree F)

Direct visual inspection may usually be made when access is sufficient to place the eye
within: - Answer-24 inches of the surface to examined.

Who must be consulted when alteration a to a piping system are be considered? -
Answer-A piping engineer

A 4 to 2 inch reducing tee is designed to reduce on its outlet. When designating the
dimension for the tee fitting it is described as a . - Answer-4 x 4 x 2
A welder operator is to be qualified by radiography using his first production weld, what
is the minimum length of the radiograph to be preformed on his weld? - Answer-36
inches

Información del documento

Subido en
19 de septiembre de 2025
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$16.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
wisdompoint
3.7
(20)
Vendido
120
Seguidores
66
Artículos
5730
Última venta
3 meses hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes