Salmonellosis - ANS A disease caused by pathogenic bacterica (often associated with chicken), which affects the intestinal tract. The primary symptom is severe diarrhea. A valve designed to open in the direction of normal flow and close with the reversal of flow. - ANS Check valve Overflow level - ANS The maximum height that water or liquid will rise in a receptacle before it flows over the rim. Backflow - ANS A hydraulic condition, caused by a difference in pressures, in which non- potable water or other fluids flow into a potable water system. RPBP - ANS A shortened name for a reduced pressure backflow preventer Air Gap - ANS In plumbing, the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or outlet supplying water to a tank, plumbing fixture, or other container, and the overflow rim of that container 2 | Page @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED potential cross connection - ANS Any arrangements of pipes, fittings, or devices that indirectly connects a potable water supply to a non-potable source Dysentery - ANS A disease (sometime waterborne) caused by pathogenic microorganisms and characterized by severe diarrhea with passage of mucus and blood Backsiphonage - ANS A backflow condition in which the pressure in the distribution system is less than atmospheric pressure (subatmospheric) Hose bib - ANS A faucet to which a hose may be attached Carrier - ANS A human or animal that carries germs and can pass them to another person without getting the disease himself. Reduced pressure zone backflow preventer - ANS A mechanical device consisting of two independnetly operating, spring-loaded check valves with a reduced pressure zone between check valves. Auxiliary supply - ANS Any water source or system, other than the potable water supply, that may be available in the building or premesis. Actual Cross Connection - ANS Any arrangement of pipes, fittings, that connects a potable water supply directly to a non-potable source at all times. Hepatitis - ANS An inflammation of the liver caused by a pathogenic virus. Symptoms are jaundice, general weakness, nausea, and the presence of dark urine. Feed water - ANS Water that is added to a commercial or industrial system and subsequently used by the system, such as

Vista previa del contenido

BACKFLOW PREVENTION ASSEMBLY
TESTER TRAINING. EXAM QUESTIONS
WITH 100% CORRECT ANSWERS |
LATEST VERSION 2025/2026.




Salmonellosis - ANS A disease caused by pathogenic bacterica (often associated with
chicken), which affects the intestinal tract. The primary symptom is severe diarrhea.


A valve designed to open in the direction of normal flow and close with the reversal of flow. -
ANS Check valve



Overflow level - ANS The maximum height that water or liquid will rise in a receptacle before
it flows over the rim.



Backflow - ANS A hydraulic condition, caused by a difference in pressures, in which non-
potable water or other fluids flow into a potable water system.



RPBP - ANS A shortened name for a reduced pressure backflow preventer



Air Gap - ANS In plumbing, the unobstructed vertical distance through the free atmosphere
between the lowest opening from any pipe or outlet supplying water to a tank, plumbing
fixture, or other container, and the overflow rim of that container



1 | Page @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED

,potential cross connection - ANS Any arrangements of pipes, fittings, or devices that
indirectly connects a potable water supply to a non-potable source



Dysentery - ANS A disease (sometime waterborne) caused by pathogenic microorganisms
and characterized by severe diarrhea with passage of mucus and blood



Backsiphonage - ANS A backflow condition in which the pressure in the distribution system is
less than atmospheric pressure (subatmospheric)



Hose bib - ANS A faucet to which a hose may be attached



Carrier - ANS A human or animal that carries germs and can pass them to another person
without getting the disease himself.



Reduced pressure zone backflow preventer - ANS A mechanical device consisting of two
independnetly operating, spring-loaded check valves with a reduced pressure zone between
check valves.



Auxiliary supply - ANS Any water source or system, other than the potable water supply, that
may be available in the building or premesis.



Actual Cross Connection - ANS Any arrangement of pipes, fittings, that connects a potable
water supply directly to a non-potable source at all times.



Hepatitis - ANS An inflammation of the liver caused by a pathogenic virus. Symptoms are
jaundice, general weakness, nausea, and the presence of dark urine.



Feed water - ANS Water that is added to a commercial or industrial system and subsequently
used by the system, such as water that is fed to a boiler to produce steam.



2 | Page @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED

, Pressure vacuum breaker - ANS A device designed to prevent backsiphonsge, consisting of
one independently operating spring-loaded check valve and an independently operating spring-
loaded air-inlet valve.



Bypass - ANS In cross-connection control, any pipe arrangement that passes water around a
protective device, causing it to be ineffective.



Gastroenteritis - ANS An intestinal disease caused by pathogenic microorganisms, which
involves inflammation of the stomach and intestines. Symptoms are diarrhea, pain, and nausea.



Back pressure - ANS A backflow condition in which a pump, elevated tank, boiler or other
means results in a downstream pressure greater than the supply pressure



Incubation period - ANS The time period that elapses between the time a person is exposed
to some disease and the time that person shows the first sign of symptom of the disease.



Cross connection - ANS Any arrangement of pipes, fitting, fixtures, or devices that connects a
non potable system to a potable water system



Atmospheric vacuum breaker - ANS A mechanical device consisting of a float check valve and
an air inlet port designed to prevent backsiphonage



Double Check Valve Assembly - ANS A testable mechanical device consiting of two
independently operating, spring-loaded check valves



Potable - ANS Water that is safe for human consumption



Backflow - ANS The reversal of the normal direction of flow




3 | Page @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED

Información del documento

Subido en
16 de septiembre de 2025
Número de páginas
17
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Brightstars
3.3
(39)
Vendido
265
Seguidores
7
Artículos
14294
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes