Oil burner test Questions and Graded Answers.
A fuel oil storage tank cannot be installed: - In the furnace room 5 feet within heating unit



What temperature does a thermal wheel automatically activate at - 165°F



Who inspects an oil burner installation - State fire marshal



Any valve used on a oil burner install must be: - Fusible valve



What form is used to pull an oil burner permit - CMR.4



What size pipe is used to CrossConnect tank outlet piping - 1/2 inch



When is an oil safety valve used - On an existing installation when a burner boiler furnace
or tank is replaced.


When must you install a draft regulator - When not exempt by manufacturer



What type of boiler must be equipped with a low water cut off - Water boilers over
500,000 BTUs & all steam boilers


All new oil burner controls must be: - Interrupted ignition



How far must continuous concrete slab extend beyond the tank perimeter - 8 inches


All protective control and emergency devices shall be series connected from the electrical
distribution panel: - Through the emergency switch, through the terminal switch, to the
service switch in the ungrounded line conductor

, If the ceiling above the burner boiler or burner furnace exceeds 12 feet in height, and additional
thermal switch shall be installed at a height of_______ and connected in series with the lower
switch. - 10 feet



An oil safety valve can perform the following functions: - Reduce pressure from its inlet
to its outlet & prevent gravity flow


Fuel oil filters should be selected for the following: - Micron range & flow rate



Ultra low sulfur fuel has no benefit to a fuel oil system - False


To ensure the best mechanical seal throughout a fuel oil delivery system the following should be
used: - Flared fittings and pipe dope



Adding a pre-heater to an oil burner will - Allow oil with a high paraffin base to flow
more easily & decrease the viscosity of a fuel oil


A probe type low-water cut off for steam should be checked - Once a year


The proper value for a resistor used to verify the F-F terminals of a Honeywell primary control
should be - 1500 ohms



Oil tanks can be produced as - Steel, fiberglass, epoxy coated steel



Black colored residue on a combustion head tells you - All the above



A white material in the flue pipe resembling beach sand is an indicator of - Unit that is
under fired

Información del documento

Subido en
8 de septiembre de 2025
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$6.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
373
Última venta
-



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes