Controls' NEWEST 2025/2026 ACTUAL EXAM
If the heater in a fixed IEC bimetallic overload relay fails,
the entire overload relay must be replaced
The nameplate of a motor indicates that the motor has an FLC of 15A and a service factor of
1.15, how much additional current can this motor safely handle for intermittent power
demands?
15A(1.15)= 17.25; 17.25A - 15A= 2.25A
The minimum allowable coil control voltage needed to keep an electromechanical device
energized is called the ___.
seal-in-voltage
A general purpose NEMA enclosure is ___.
type 1
NEC Article 430, Part VII covers ___.
, motor controllers
What Describes A Retro-Reflective Scan?
The Scanning Method In Which A Target Is Detected As It Passes Between A Photo Electric
Sensor And A Reflector
If A Duty Cycle Includes Significant Plugging Or Jogging, Select An ___.
AC-4 Rated Motor Control Device
Jogging Is Also Referred To As ___.
Inching
Most Transient Suppression Modules Consist Of An RC Circuit That Is Designed To Suppress Coil
Voltage Transients To Approximately. What Percentage Of The Peak Coil Supply Voltage?
200%
Pilot Devices Are Used In Motor Control Circuits To Provide ___.
Sequencing And Automatic Operation Within Certain Parameters
Which Of The Following Are Primarily Designed For Use With Induction Motor Loads And To
Withstand The Interrupt Current Of A Locked Rotor?