Which of the following are a type of sprinkler?
A) ESFR
B) EC About _____ % of fire deaths are attributed to smoke
C) AF inhalation and not to burns.
D) A and B - ANSWER -A and B A. 55%
B. 60%
C. 65%
D. 70% - ANSWER -65%
Foam water system design and installation requirements
are regulated by ___________.
A. NFPA 13
B. NFPA 13R When performing maintenance inspections of occupancies
C. NFPA 25 with alarm systems, the first step will be to:
D. NFPA 16 - ANSWER -NFPA 16 A) Check for green light indicating normal operation
B) Confirm monitoring status with alarm company
C) Confirm panel is locked and inaccessible to public
D) Confirm system has been tested by licensed alarm
True or False, NFPA 72 allows only manual pull stations contractor and has a current inspection tag -
and water flow detection devices to be used on shunt ANSWER -Confirm system has been tested by
systems. Fire detection devices are not permitted. - licensed alarm contractor and has a current inspection tag
ANSWER -True
Most people are well aware of the dangers of fire but less
The fire alarm control panel (FACP) is essentially the aware of the dangers of smoke inhalation. About ___% of
_____ of the system. - ANSWER -Brain of fire deaths are attributed to smoke inhalation and not to
burns.
A) 65
B) 80
Heat sensing fire detector color coding has a RED extra C) 92
high temperature rating of? D) 75 - ANSWER -65
A.) 0-99f
B.)175-249f
C.) 325-399f
D.) 500-575f - ANSWER -325-399f If required, pull stations should be placed within ___ feet
of every exit.
a) 4
b) 5
According to NFPA, travel distances to a manual pull c) 10
station should not exceed _____ feet. d) does not matter what distance, as long as it is not
A. 100 blocked - ANSWER -5
B. 200
C. 300
D. 400 - ANSWER -200
T or F: The development of clean-agent fire-extinguishing
systems began in the late 1940s. - ANSWER -True
What color tag is used to indicate that an alarm system is
impaired?
A. White NFPA 10 has assigned a maximum travel distance of __
B. Yellow feet from the hazard to a Class K extinguisher?
C. Blue A) 30
D. Red - ANSWER -Red B) 50
C) 75
, TCFP Inspector's Class II Exam With 100% Correct Answers
D) 100 - ANSWER -30 A. mechanical
B. electrical
C. slippery
D. bubbly - ANSWER -mechanical
If an extinguisher is suitable for use on a particular class
of fire, the picture-symbol background is what color?
A.) Red
B.) Light Blue A properly placed fire extinguisher will result in all of the
C.) Black following except:
D.) Grey - ANSWER -Light Blue A. Visible, signage not necessary
B. Not be blocked by storage or equipment
C. Near points of egress and ingress
D. Near normal paths of travel - ANSWER -Visible,
Which one of the following is not considered a proper signage not necessary
placement of a fire extinguisher?
A. Visible and marked with legible signage.
B. Near Points of egress or ingress.
C. Sitting on top of a work bench with no mount. A dry chemical extinguishing system is used wherever
D. Near formal paths of travel. - ANSWER -Sitting rapid fire extinguishment is required and where ________
on top of a work bench with no mount. of the burning material is unlikely.
A) exploding
B) oxidation
C) smothering
Foam extinguishes a fire by one or more of the four D) reignition - ANSWER -reignition
following methods except:
A. Smothering
B. Seperating
C. Suppressing NFPA 10 establishes a Class B flammable liquid fire with
D. Blanketing - ANSWER -Blanketing depth at____
A. 1/2"
B. 1/4"
C. < 1/4"
In regards to carbon dioxide fire-extinguishing systems, D. > 1/2" - ANSWER -1/4"
total flooding systems are designed to deliver at least ___
percent concentration of CO into and enclosed area.
A. 21
B. 19 What percentage of fire deaths is attributed to smoke
C. 34 inhalation?
D. 15 - ANSWER -34 A) 65%
B) 50%
C) 42%
D) 15% - ANSWER -65%
What is the fuel classification for combustible metals?
A. Class A
B. Class B
C. Class C True/False
D. Class D - ANSWER -Class D A critical feature and limitation of special-agent fire-
extinguishing systems is the quality of agent available in
the system. - ANSWER -False - "quantity"
Most fire-extinguishing foam concentrates in use today
are of the _____ type, which means they must be
proportioned with water and mixed with air (aerated) High expansion foam fire extinguishing systems typically
before they can be used. have the following expansion rates: