Content preview

NERC RC EXAM PREP QUESTIONS & ANSWERS
When does the Contingency Reserve Restoration Period begin?

A. At the top of the hour after the Reportable Disturbance
B. At the start of the Reportable Disturbance
C. At the end of the Disturbance Recovery Period
D. When all Contingency Reserve has been exhausted - Answers - C. At the end of
the Disturbance Recovery Period

Which of the following terms is defined as the scan rate values of a Balancing
Authority's ACE measured in MW, which includes the difference between the Balancing
Authority's Net Interchange Actual and its Net Interchange Scheduled, plus its
Frequency Bias obligation, plus any known meter error?

A. Automatic Time Error
B. Reporting ACE
C. ACE Control Error
D. Reserve Sharing Group Reporting - Answers - B. Reporting ACE

Which of the following terms applies to the Western Interconnection only, and the
addition of a component to the ACE equation that modifies the control point for the
purpose of continuously paying back Primary Inadvertent Interchange to correct
accumulated time error?

A. Reporting ACE
B. Automatic Time Error Correction
C. Reserve Sharing Group Reporting ACE
D. Regulation Reserve Sharing Group - Answers - B. Automatic Time Error Correction

A Balancing Authority's CPS1 calculation is computed using its clock-minute average of
two values. What are those two values?

A. Reporting ACE and Frequency Error
B. Actual and Scheduled Net Interchange NIA and NIS.
C. L10 and Reporting ACE
D. Actual and Scheduled Frequency (FA and FS) - Answers - A. Reporting ACE and
Frequency Error

To conform to CPS requirements, a Balancing Authority must have which of the
following?

A. CPS1 greater than or equal to 90% or BAAL greater than or equal to 100%.
B. CPS1 greater than or equal to 100% and ACE does not exceed BAAL more than 15
consecutive minutes.

,C. CPS1 greater than or equal to 100% and ACE does not exceed BAAL more than 30
consecutive minutes.
D. CPS1 greater than or equal to 90% and ACE does not exceed BAAL more than 30
consecutive minutes. - Answers - C. CPS1 greater than or equal to 100% and ACE
does not exceed BAAL more than 30 consecutive minutes.

What should a Balancing Authority set Scheduled Frequency to for a slow Time Error
Correction?

A. 60.02 Hz
B. 59.98 Hz
C. 59.80 Hz
D. 60.20 Hz - Answers - A. 60.02 Hz

Which of the following is a potential source of Contingency Reserve?
1. Offline generation that takes 10 minutes to start and ramp to full output
2. Online generation at full load
3. Controllable load resources
4. Voltage reductions

A. 3 and 4
B. 2 and 3
C. 1 and 3
D. 1 and 2 - Answers - C. 1 and 3

In an Interconnection, which of the following is required to be in the metered boundaries
of a Balancing Authority Area?

A. Generation
B. Transmission
C. Load
D. All are required to be within the metered boundaries of a Balancing Authority. -
Answers - D. All are required to be within the metered boundaries of a Balancing
Authority.

The minimum compliance for NERC Disturbance Control Standard (DCS) is ________?

A. 90% of all reportable disturbances
B. 90% of all disturbances
C. 100% for all reportable disturbances
D. 100% for all generator tips - Answers - C. 100% for all reportable disturbances

A Balancing Authority has a normal load of around 8500 MW. Its most severe single
contingency is a 700 MW coal-fired steam unit. At 0810, the ACE value was at -55 MW
when a 600 MW generator in the Balancing Authority's northern area tripped off line due
to a generator differential. This event resulted in a large negative ACE for the Balancing

,Authority. What value must ACE return to and in what time frame to avoid a DCS
violation?

A. -55 MW ACE in 15 minutes
B. Zero ACE in 10 minutes
C. -55 MW ACE in 10 minutes
D. Zero ACE in 15 minutes - Answers - A. -55 MW ACE in 15 minutes

If a Reserve Sharing Group member has experienced a Reportable Disturbance
condition but does not call for reserve activation from other members, the entire group is
considered to be in a disturbance condition.

A. True
B. False - Answers - B. False

You are a Balancing Authority Operator. A neighboring Balancing Authority in the
Interconnection suddenly has a 500 MW generator trip due to a generator ground. What
part of the ACE equation, ACE = (NIA-NIS) - 10B (FA-FS) - IME, allows you and other
Balancing Authorities in the Interconnection to help stabilize the Interconnection
frequency error?

A. (FA- FS) - IME
B. NIA - NIS
C. 10B (FA-FS)
D. 4 IME - Answers - C. 10B (FA-FS)

Balancing Authority A is scheduled to import a net 200 MW and is actually importing a
net 150 MW. The Bias Setting is -100 MW/.1 HZ and Actual Frequency is 59.95 Hz.
What is Balancing Authority A's ACE reading?

A. +100 MW
B. -100 MW
C. 0 MW
D. -55 MW - Answers - C. 0 MW

Which of the following elements is NOT included in the ACE equations frequency
component?

A. Actual Frequency (FA)
B. Scheduled Frequency (FS)
C. Frequency Bias Setting (B)
D. Meter Error (IME) - Answers - D. Meter Error (IME)

A Balancing Authority is slightly undergenerating its Actual System Frequency (FA) is
60.03 Hz. What is the result of the Balancing Authority's action?

, A. The Balancing Authority is helping the Interconnection Frequency.
B. The Balancing Authority is in CPS1 violation.
C. The Balancing Authority is hurting the Interconnection Frequency.
D. The Balancing Authority is in BAAL violation - Answers - A. The Balancing Authority
is helping the Interconnection Frequency

Which statement best describes the CPS1 requirement?

A. ACE must follow changes in load and schedule within a bandwidth called L10.
B. The Responsible Entity must operate so its CPS1 is greater than or equal to 100%
for the preceding 12-month period.
C. The average ACE for a defined 10-minute period must be within a limit called L10.
D. ACE must start to return to zero one minute after crossing zero. - Answers - B. The
Responsible Entity must operate so its CPS1 is greater than or equal to 100% for the
preceding 12-month period

Turbine governors arrest Frequency deviations. Of the following, which control system
compares and brings Net Actual Interchange back in line or as close to Net Scheduled
Interchange as possible?

A. Load Response
B. Flat Frequency Control
C. Automatic Generation Control
D. Automatic Voltage Regulation - Answers - C. Automatic Generation Control

Automatic Generation Control uses the ACE equation to ________.

A. Minimize Inadvertent Interchange among Balancing Authority areas
B. Provide frequency support for the Interconnection
C. Both answers are correct
D. Neither answer is correct - Answers - C. Both answers are correct

Which part of the ACE equation reflects Pseudo-Ties values?

A. Scheduled Net Interchange component, NIS
B. Actual Net Interchange component, NIA
C. Frequency component, FA - FS
D. Pseudo-Ties are not included in the ACE equation. - Answers - B. Actual Net
Interchange component, NIA

A Balancing Authority's frequency indication has become erratic and unreliable. Which
AGC mode should the Balancing Authority operate in?

A. Manual Control
B. Flat Frequency Control
C. Tie Line Bias Control

Written for

Institution
NERC RC
Course
NERC RC

Document information

Uploaded on
July 15, 2025
Number of pages
46
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$16.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA YALA UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
2128
Member since
4 year
Number of followers
1446
Documents
56974
Last sold
3 days ago

3.8

360 reviews

5
179
4
61
3
48
2
17
1
55

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions