RETA INDUSTRIAL REFRIGERATION EXAM 2 LATEST 2024 ACTUAL EXAM (2VERSION A AND VERSION B) COMPLETE 170 QUESTIONS AND CORRECT ANSWERS

Institución
RETA INDUSTRIAL REFRIGERATION
Grado
RETA INDUSTRIAL REFRIGERATION

Vista previa del contenido

RETA INDUSTRIAL REFRIGERATION EXAM 2 LATEST 2024 ACTUAL EXAM (2VERSION A AND VERSION B)
COMPLETE 170 QUESTIONS AND CORRECT

Which of the following factors listed below does not affect heat transfer?

(pg. 1-2)

A) Temperature Difference

B) Surface Area

C) Thermal Conductivity

D) Density - (answer) D) Density



An example of a poor conductor of heat is? (pg. 1-3)

A) Aluminum Tubing

B) Schedule 40 Steel Pipe

C) Wood

D) Water - (answer) C) Wood



Thermal conductivity ('K') is? (pg. 1-3)

A) Exactly the same for any metal

B) The number of BTU's that will pass in 1 hour through a material 1" thick with an area of 1 sq. ft. if the
temperature difference from one side to the other is 1°F

C) A measure of the total energy (heat content) per pound of refrigerant measured in BTU's

D) A relationship between heat and temperature that is useful in determining discharge temperatures. It
is heat moved into or out of the process, divided by the absolute temperature in BTU's/pound/R -
(answer) B) The number of BTU's that will pass in 1 hour through a material 1" thick with an area of 1
sq. ft. if the temperature difference from one side to the other is 1°F



Which is NOT a common source of fouling of a heat exchange surface?

(pg. 1-7)

A) Water

B) Oil

C) Frost

D) Dirt - (answer) A) Water

,RETA INDUSTRIAL REFRIGERATION EXAM 2 LATEST 2024 ACTUAL EXAM (2VERSION A AND VERSION B)
COMPLETE 170 QUESTIONS AND CORRECT



Which statement is true? (pg. 1-3)

A) The higher the 'k' factor, the greater the thermal conductivity

B) The lower the 'k' factor, the greater the thermal conductivity

C) The higher the 'k' factor, the lower the thermal conductivity

D) The 'k' factor is not associated with thermal conductivity - (answer) A) The higher the 'k' factor, the
greater the thermal conductivity



Optimum 'U' factor for the given material that the heat exchanger is made of results when? (pg. 1-7/8)

A) There is no impeding substance such as ice, dirt, or oil on the surfaces of the heat exchanger tubes

B) Maximum airflow across the evaporator is achieved

C) The system is operating with the design recirculation low

D) The system is maintaining temperature - (answer) A) There is no impeding substance such as ice,
dirt, or oil on the surfaces of the heat exchanger tubes



When air flow is decreased across a heat exchange surface, cooling capacity is? (pg. 1-10)

A) Reduced

B) Increased

C) Not changed because area is not changed

D) Not changed because evaporator temperature is not changed - (answer) A) Reduced



Centrifugal fans have an advantage over propeller fans in that they ______________ than prop fans? (pg.
1-12)

A) Require less physical space

B) Consume more hp per CFM of air moved

C) Are quieter

D) Have fewer components to maintain - (answer) C) Are quieter



The operating engineer? (pg. 1-7)

,RETA INDUSTRIAL REFRIGERATION EXAM 2 LATEST 2024 ACTUAL EXAM (2VERSION A AND VERSION B)
COMPLETE 170 QUESTIONS AND CORRECT

A) Cannot change the 'k' factor of the metal but has some control of the overall 'U' factor for the
evaporator as a unit

B) Can increase 'k' factor by increasing the air velocity over the evaporator and has some control of the
overall 'U' factor for the evaporator as a unit

C) Should allow frost to collect on the evaporator increase 'k' factor

D) Can increase 'k' factor by starting another compressor - (answer) A) Cannot change the 'k' factor of
the metal but has some control of the overall 'U' factor for the evaporator as a unit



The limiting factor of an evaporator's capacity that the operator cannot control is? (pg. 1-7)

A) Suction Temperature

B) Suction Pressure

C) Evaporator Size

D) Refrigerant Liquid Feed Flow - (answer) C) Evaporator Size



The best way to keep an evaporator from being affected by oil build-up is to? (pg. 1-8)

A) Operate the system at the correct evaporator temperature

B) Periodically remove oil from the oil collection points

C) Set hot gas defrost cycle for a minimum of 30 minutes

D) Increase air flow across the evaporators - (answer) B) Periodically remove oil from the oil collection
points



The effectiveness of a heat transfer surface depends on several factors. One factor the operator has
control over is? (pg. 1-8)

A) Evaporator surface area

B) Material the evaporator is made of

C) Type of fans used

D) Cleanliness of the evaporator - (answer) D) Cleanliness of the evaporator



One advantage of using axial type fans is? (pg. 1-12)

A) Quieter operation

, RETA INDUSTRIAL REFRIGERATION EXAM 2 LATEST 2024 ACTUAL EXAM (2VERSION A AND VERSION B)
COMPLETE 170 QUESTIONS AND CORRECT

B) They require less motor horsepower per CFM

C) They can move air further across the space to be cooled

D) They can work against a higher static pressure - (answer) B) They require less motor horsepower per
CFM



Which of the following is NOT a result of scale build-up on a condenser coil? (pg. 1-13)

A) Reduced heat transfer

B) Increased operating cost

C) Increased 'U' value

D) Increased condensing temperatures - (answer) C) Increased 'U' value



If 'R' value is doubled, what will happen to the heat transfer rate (assuming the temperature difference
and the area do not change)? (pg. 1-13)

A) The rate of heat that is transferred will be double

B) The rate of heat that is transferred will be cut in half

C) The rate of heat that is transferred does not change

D) The conductance is doubled so that heat transfer rate is increased - (answer) B) The rate of heat that
is transferred will be cut in half



What happens to the theoretical capacity of an evaporator in a 0°F freezer if the ammonia evaporating
pressure is dropped from 8.96 PSIG to 6.11 PSIG? (pg.

A) The capacity of the evaporator is reduced by 50%

B) The capacity of the evaporator is doubled

C) The capacity of the evaporator is not changed

D) The capacity of the evaporator is increased by 50% - (answer) C) The capacity of the evaporator is
not changed



Damaged insulation on the suction line in an ammonia refrigeration system will? (pg. 1-14)

A) Not change the efficiency of the system because suction pressure will not change

B) Cause efficiency loss and potential damage to the suction line

Escuela, estudio y materia

Institución
RETA INDUSTRIAL REFRIGERATION
Grado
RETA INDUSTRIAL REFRIGERATION

Información del documento

Subido en
30 de junio de 2025
Número de páginas
66
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$21.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Opticaltest Wgu
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
4485
Miembro desde
1 año
Número de seguidores
3
Documentos
1304
Última venta
1 mes hace

5.0

1012 reseñas

5
991
4
9
3
6
2
2
1
4

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes