NICET - Fire Alarm Systems (Level 2) UPDATED Exam Questions and CORRECT Answers 2000 cfm - CORRECT ANSWER - The International Mechanical Code requires a duct smoke detector in the return for units over ________ cfm 15000 - CORRECT ANSWER - The International Mechanical Code (IMC) requires a duct smoke detector in the supply for units over __________ cfm 4 hours - CORRECT ANSWER - Digital alarm communicator transmitters (DACT) which use call forwarding to the DACR shall be tested with what frequency

Mostrar más Leer menos
Institución
Nicet
Grado
Nicet











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Nicet
Grado
Nicet

Información del documento

Subido en
13 de junio de 2025
Número de páginas
59
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NICET - Fire Alarm Systems (Level 2)
UPDATED Exam Questions and
CORRECT Answers
2000 cfm - CORRECT ANSWER - The International Mechanical Code requires a duct
smoke detector in the return for units over ________ cfm


15000 - CORRECT ANSWER - The International Mechanical Code (IMC) requires a duct
smoke detector in the supply for units over __________ cfm


4 hours - CORRECT ANSWER - Digital alarm communicator transmitters (DACT) which
use call forwarding to the DACR shall be tested with what frequency?


600v - CORRECT ANSWER - NPLFA cables shall be insulated to __________ v



300v - CORRECT ANSWER - PLFA cables shall be insulated to _______ v



d - CORRECT ANSWER - For sprinkler systems what type of signal is a fire pump
running?
a. alarm
b. supervisory
c. trouble
d. A and B


AHJ - CORRECT ANSWER - A positive alarm sequence requires the approval of the
___________.


Semniannually - CORRECT ANSWER - How often shall a remote annunciator used at the
main entrance of a low-rise residential apartment building be inspected?

,Normal - CORRECT ANSWER - According to NFPA 72, the off-normal signal of a
tamper switch control valve used in sprinkler piping that is required for pressure-actuated water
flow alarm switch, shall not be restored at any valve position except _____________?


12 in; 8 ft - CORRECT ANSWER - When installing a heat-sensing fire detector on the
bottom of a beam, the beam must be less than _____________ inches in depth and
_____________ feet on center?


b - CORRECT ANSWER - Where a door is released to provide a 2-hour fire rating
directly from the smoke detector, the detector shall be ______________
a. mounted as close as possible to the door being released
b. listed for door releasing service
c. identified for door releasing service
d. of the photoelectric type only


d - CORRECT ANSWER - According to NFPA, smoke detectors installed in the ducts of
HVAC systems shall initiate:
a. alarm
b. supervisory
c. trouble
d. a or b


d - CORRECT ANSWER - According to the IBC, shop drawings shall include:
a. floor plan that indicates the use of all rooms
b. annunciators
c. voltage drop calculations
d. all of the above

,Master Control Unit - CORRECT ANSWER - The location of remotely located power
supplies shall be identified at the ________________


lower; 24 in - CORRECT ANSWER - Heat detectors will be installed in an elevator
hoistway to shut down power to the elevator prior to sprinkler activation. The heat detectors need
to have a _______________ temp rating and shall be located ______________ in from the
sprinkler head.


Group B - CORRECT ANSWER - A local community college is what type of occupancy
classification?


Group E - CORRECT ANSWER - What type of occupancy group for a school below the
12th grade?


Group B - CORRECT ANSWER - What type of occupancy group for a school above the
12th grade?


Class E - CORRECT ANSWER - A pathway shall be designated as _______________
(what class?) when it is NOT monitored for integrity?


40 feet; 5 feet - CORRECT ANSWER - Manual fire alarm boxes shall be installed on both
sides of grouped openings over ____________ feet in width and within __________ feet of each
side of the grouped opening.


c - CORRECT ANSWER - A fire pump was installed in a low-rise residential building
with a required fire alarm system. What are the requirements for the pump running signal?
a. It shall be a supervisory signal.
b. It shall be an alarm signal.
c. It shall be a supervisory or alarm signal.
d. A pump running signal is not required.

, d - CORRECT ANSWER - A licensed electrician was hired to install duct detectors
mounted on the air ducts of a 5,000 CFM unit. Which of the follwoing statements is true?
a. The smoke detector must be listed for use in air ducts
b. The detectors can initiate a supervisory signal
c. The detectors can initiate an alarm signal
d. All of the above


d - CORRECT ANSWER - Record drawings, as-builts, shall contain approval
documetnation resulting from any _______________?
a. variances
b. performance-based designs
c. risk analysis
d. all of the above


No - CORRECT ANSWER - An electrically locked door is connected to the fire alarm
system in order to unlock in the event of an alarm. The customer has requested that a feature be
added (push button) to lock the doors even while in alarm. Is this permitted by code?


90 seconds - CORRECT ANSWER - According to the 2022 edition of NFPA 13, electric
waterflow devices must activate within _________________ of water flow beginning and
continue until the flow stops


Elevator cars - CORRECT ANSWER - According to teh IBC, strobe lights/appliances
shall not be required in ______________?


300v - CORRECT ANSWER - Communications wires (Coaxial cables) shall have a
voltage rating of not less than _________ volts


30 in - CORRECT ANSWER - What is the minimum workspace width in front of
electrical equipment (This allows enough room for a person to face the equipment without
having to turn the upper body to work on the equipment)?

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1072
Miembro desde
1 año
Número de seguidores
102
Documentos
68976
Última venta
2 días hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

170 reseñas

5
73
4
30
3
45
2
8
1
14

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes