What is a purpose of a control valve - Answer: Control Flow to water based fire protection system



The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system
side of the dry pipe valve? - Answer: the same pressure



What type of test shall be provided when a valve is returned to service to determine that the valve is
open? - Answer: Valve status test



What is a fire service main? - Answer: A pipe and its appurtenances on private property/ Pipe between a
source of water and the base of the system riser



Name the system that utilizes a plate through which a passes a specific amount of foam concentrate at a
specific pressure. - Answer: Orifice Plate Proportioning



During an inspection, which of the following would be identified as a sprinkler which shall be replaced? -
Answer: Corrosion



What are the inspection requirements for hangers and seismic braces installed in concealed spaces? -
Answer: Periodic inspection is not required



Gauges shall be replaced every _____ or tested every _____ by comparison with a calibrated gauge -
Answer: 5 years/ 5 years



Where air pressure supervision is connected to a constantly attended location gauges shall be inspected
______? - Answer: Monthly

, Sprinklers installed in areas that are inaccessible for safety consideration, due to process operations
____ be ____ during each scheduled shutdown? - Answer: Shall/ Inspected



What type of valve is designed for the purpose of reducing downstream water pressure under both
residual and static conditions - Answer: Pressure reducing valve



PIV and OS&Y shall be backed a __________ from the fully open position to prevent jamming. - Answer:
1/4 turn



Gauges not accurate to within _______ percentage of the full scale shall be recalibrated or replaced? -
Answer: 3 percent



When there is a _________ reduction in full flow pressure, when compared to original acceptance test,
the cause of the reduction shall be identified and corrected. - Answer: 10 Percent



An informational sign shall be placed at the _______ supplying the antifreeze loop, dry system, pre
action system, or auxiliary systems control valve. - Answer: System Control Riser



Information signs should indicate which of the following? - Answer: Location if the area served by
system, the presence and location of antifreeze or other auxiliary systems, the presence and location of
heat tape



Which of the following signs require a quarterly inspection to verify that it is securely attached to the
sprinkler riser? - Answer: Hydraulic Design Information sign



Which of the following would be an acceptable material for the information sign to be made of? -
Answer: Rigid plastic/ Metal



How often shall the system information sign be tested? - Answer: Testing is not required for the
information sign



Sprinklers shall be tested for sensitivity and functionality at ______ PSI - Answer: 5

Información del documento

Subido en
10 de junio de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
YourExamplug
4.1
(74)
Vendido
223
Seguidores
27
Artículos
18055
Última venta
6 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes