Commercial kitchen Grease duct systems serving a Type I hood shall be designed and installed to provide an air velocity within the duct system of not less than ______ feet per minute: a: 1000 b: 500 c: 400 d: 250 - CORRECT ANSWER-b: 500 Refer: IMC Code 506.3.4 The minimum openable area to the outdoors shall be ____ of the floor area being naturally ventilated: a: 6% b: 8% c: 4% d: 2% - CORRECT ANSWER-c: 4% Refer: IMC Code 504.7 Fire dampers are not required at penetrations of shafts where the steel exhaust subducts extend at least _______ vertically in exhaust shafts provided that there is a continuous airflow upward to the outdoors: a: 25 inches b: 22 inches c: 32 inches d: 28 inches - CORRECT ANSWER-b: 22 inches Refer: IMC Code 607.5.5 Exp 1.1 Underground Ducts shall have a minimum slope of _______ per foot to allow drainage to a point provided with access: a: 1/2 inch b: 1/6 inch c: 1/4 inch d: 1/8 inch - CORRECT ANSWER-d: 1/8 inch Refer: IMC Code 603.8.1 Liquid adhesive coatings used on air filters for air conditioning or heating systems shall have a flash point not lower than _______ : a: 200°F b: 250°F c: 350°F d: 325°F - CORRECT ANSWER-d: 325°F Refer: IMC Code 605.1Connectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue: a: 10 inches b: 12 inches c: 16 inches d: 14 inches - CORRECT ANSWER-b: 12 inches Refer: IMC Code 801.12

Mostrar más Leer menos
Institución
KY HVAC Journeyman
Grado
KY HVAC Journeyman









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
KY HVAC Journeyman
Grado
KY HVAC Journeyman

Información del documento

Subido en
6 de junio de 2025
Número de páginas
14
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Vista previa del contenido

KY HVAC Journeyman
Commercial kitchen Grease duct systems serving a Type I hood shall be designed and
installed to provide an air velocity within the duct system of not less than ______ feet
per minute:
a: 1000
b: 500
c: 400
d: 250 - CORRECT ANSWER-b: 500
Refer: IMC Code 506.3.4

The minimum openable area to the outdoors shall be ____ of the floor area being
naturally ventilated:
a: 6%
b: 8%
c: 4%
d: 2% - CORRECT ANSWER-c: 4%
Refer: IMC Code 504.7

Fire dampers are not required at penetrations of shafts where the steel exhaust
subducts extend at least _______ vertically in exhaust shafts provided that there is a
continuous airflow upward to the outdoors:
a: 25 inches
b: 22 inches
c: 32 inches
d: 28 inches - CORRECT ANSWER-b: 22 inches
Refer: IMC Code 607.5.5 Exp 1.1

Underground Ducts shall have a minimum slope of _______ per foot to allow drainage
to a point provided with access:
a: 1/2 inch
b: 1/6 inch
c: 1/4 inch
d: 1/8 inch - CORRECT ANSWER-d: 1/8 inch
Refer: IMC Code 603.8.1

Liquid adhesive coatings used on air filters for air conditioning or heating systems shall
have a flash point not lower than _______ :
a: 200°F
b: 250°F
c: 350°F
d: 325°F - CORRECT ANSWER-d: 325°F
Refer: IMC Code 605.1

, Connectors shall connect to a chimney flue at a point not less than ______ above the
lowest portion of the interior of the chimney flue:
a: 10 inches
b: 12 inches
c: 16 inches
d: 14 inches - CORRECT ANSWER-b: 12 inches
Refer: IMC Code 801.12

Liquids having flash points at or above 100°F (38°C) and below 140°F (60°C) comes
under ________ combustible liquid:
a: Class I
b: Class II
c: Class IIIA
d: Class IIIB - CORRECT ANSWER-b: Class II

Where located adjacent to walkways, the vertical termination of mechanical draft
systems shall be not less than ______ above the level of the walkway:
a: 7 feet
b: 5 feet
c: 3 feet
d: 4 feet - CORRECT ANSWER-a: 7 feet
Refer: IMC Code 804.3.5.1


Masonry chimney flues shall be provided with a cleanout opening having a minimum
height of ______ :
a: 6 inches
b: 12 inches
c: 8 inches
d: 10 inches - CORRECT ANSWER-a: 6 inches
Refer: IMC Code 801.13

Commercial Kitchen Exhaust equipment serving a Type I hood shall have a clearance
to combustible construction of not less than ______ :
a: 30 inches
b: 12 inches
c: 24 inches
d: 18 inches - CORRECT ANSWER-d: 18 inches
Refer: IMC Code 506.5.4

Steam-Heating Boiler operated at pressures not exceeding ______ for steam:
a: 20 psi
b: 15 psi
c: 10 psi
d: 25 psi - CORRECT ANSWER-b: 15 psi
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Brainarium Delaware State University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1828
Miembro desde
2 año
Número de seguidores
1043
Documentos
22327
Última venta
1 día hace

3.8

317 reseñas

5
147
4
60
3
54
2
16
1
40

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes