SAEP - Answers :-Short latency auditory evoked potentials
-electrical responses of the auditory pathways that occur withing 10-15ms of an
appropriate acoustic stimulus in normal subjects
-this term encompasses two categories of events: the "electrocochleaogram" and the
"BAEPs"

BAER - Answers :-Brainstem Auditory Evoked Responses
- Responses of the auditory nerve, brainstem and higher subcortical structures to
acoustic stimulation

ABR - Answers :Auditory Brainstem Responses

AEP - Answers :Auditory Evoked Potentials

Electrocochleography (ECochG) - Answers :- Recording of JUST wave I
- assesses function of ONLY Cochlea and includes three components:
1. the cochlear microphones
2. summating potentials
3. the auditory nerve compound action potential

What is the analysis time for ECochG? - Answers :5msec

What is the Cochlear Microphonic Generator? - Answers :outer hair cells in organ of
corti (Cochlea)

In the OR, what is the click polarity of choice for ECochG and why? - Answers
:Alternating Click Polarity becuase it cancels cochlear microphonics and artifact stimuls
and improves the identification of Wave I

Wave I can be differentiated from choclear microphonics based on what? - Answers
:click polarity

Rarefraction Clicks - Answers :-Goes in one direction with negative clicks
- Negative pressure on the earspeaker diaphragm
- Pulls AWAY from the tympanic membrane
- Best Wave I amplitude

Condensation Click - Answers :- Goes the OPPOSITE direction with positive clicks
- Positive pressure on the earspeaker diaphragm
- Pushes toward the tympanic membrane
- Best Wave V amplitude

Alternating Click - Answers :- Negative AND Positive pressure on the earspeaker
diaphragm

, - Cancels cochlear microphonic
- Cancels stim artifact
- Intraoperative monitoring

BAEP - Answers :-Brainstem Auditory Evoked Potentials
- resonses of the auditory nerve, brainstem and higher subcortical structions to acoustic
stimulation

Electrodes used for BAEPs - Answers :- Disc EEG electrodes applied with collodion and
sealed with plastic tape or sheet to prevent drying and providing protection from blood
or other fluids
-Bone wax secures the earphones. It does NOT protect the canal from fluid entry
- subdermal needle elecrodes similarly secured

In ordinary recordings between vertex and earlobe or mastoid electrodes, what should
the "vertex-negative" components of BAEPs which follow each vertex-positive wave be
labeled or designated? - Answers :I' through VI'

What is the recommended stimulus for BAEPs? - Answers :"broad-band" clicks which is
the acoustic energy of which is spread over a wide range of audio frequencies

How should broad-band clicks be generated? - Answers :by driving with a 100 usec
rectangular pulse (single monophasic square wave) and by a a standard audiometric
earspeaker having a relative flat frequency spectrum or through ear insertions for IOM
cases

At what stimulus rate do waves I, III, VI, and VII become particularly reduced in
amplitude? What stimulus rates are best suited to resolve these peaks? - Answers :- at
rates higher than 10/s
-rates of 8 - 10/s

What is recommended for the contralateral ear (nonstimulated ear) in order to eliminate
crossover responses? - Answers :That the contralateral ear be masked by white noise
at 60dB SPL

Recommended system bandpass for BAPEs? - Answers :10-30 to 2,500-3,000 Hz (-
3dB) and 60 cycle filter (Notch) off

Filter Rolloff for BAEPs? - Answers :- 12 dB/octave for low frequencies
- 24 dB/octave for the high frequencies
- A high frequency cutoff of 1,500 Hz is acceptable for intraoperative BAEPs

What is the recommended analysis time from stimulus onset? - Answers :10-15ms

What analysis time is essential for neonatal, pathology and intraoperative BAEP
recordings and why? - Answers :15ms because Lower temperature in the operating

Información del documento

Subido en
3 de junio de 2025
Número de páginas
11
Escrito en
2024/2025
Tipo
Otro
Personaje
Desconocido
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA
3.8
(380)
Vendido
2244
Seguidores
1452
Artículos
64014
Última venta
2 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes