Fire Protection Systems Exam Questions And Answers 100% Pass What are heat detectors called that are spaced throughout an occupancy with each detector covering a specific floor area? A. Sprinkler heads B. Stand-alones C. Spot detectors D. Soldiers - ANS C. Spot detectors Older heat detectors lack what feature that makes it difficult to track down the cause of an alarm? A. Color-coding of their activation thresholds B. Wide spaced combs C. Visual triggers that tell which device was activated D. Narrow spaced combs - ANS C. Visual triggers that tell which device was activated In a cross-zoned smoke detection system, what must happen after the activation of a detector before the actual alarm will sound? A. A second detector must activate. ©EVERLY 2025 ALL RIGHTS RESERVED B. A human must manually activate the alarm. C. The detector must continue reverting to alarm after three attempts at auto-reset. D. A sprinkler head must also be activated and flow water. - ANS A. A second detector must activate. What type of fire alarm annunciation system identifies the zone in which the alarm was initiated both at the alarm control panel and through the audio notification device? A. Zoned B. Wired C. Coded D. Central - ANS C. Coded Which is one of the functions sprinkler heads perform? A. Notify occupants of the fire B. Auto-restore when the fire is out C. Activate the system D. Report any trouble in the system - ANS C. Activate the system Where are the main sprinkler system valves usually installed? A. Outside the building, coming up out of the ground, and then going back down underground B. Outside the building, coming up out of the ground on a post C. On the main riser, above the water supply control valve D. On the main riser, below the water supply control valve - ANS C. On the main riser, above the water supply control valve ©EVERLY 2025 ALL RIGHTS RESERVED The preferred water source for a sprinkler system is a: A. private pressure tank. B. private non-pressure static supply. C. elevated water supply cistern. D. municipal water system. - ANS D. municipal water system What does the W stand for in WPIV( ______ post indicator valve)? A. Wall B. Water C. Waiting D. Wrapped - ANS A. Wall In a pre-action sprinkler system, what else must happen in addition to a head being activated before water will flow? A. The alarm condition must persist for a set time. B. The preliminary mini-discharge must fail to put out the fire. C. Some physical shock must have occurred to the system. D. A secondary device must be activated. - ANS D. A secondary device must be activated. The normal type of sprinkler system used where there is a risk of the system freezing is a A. dry system. C. residential system. B. wet system. D. COz system. - ANS A. dry system.

Mostrar más Leer menos
Institución
Fire Protection Systems
Grado
Fire Protection Systems










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Fire Protection Systems
Grado
Fire Protection Systems

Información del documento

Subido en
15 de mayo de 2025
Número de páginas
29
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

©EVERLY 2025 ALL RIGHTS RESERVED




Fire Protection Systems Exam Questions And
Answers 100% Pass



What are heat detectors called that are spaced throughout an occupancy with each detector
covering a specific floor area?


A. Sprinkler heads
B. Stand-alones
C. Spot detectors

D. Soldiers - ANS C. Spot detectors


Older heat detectors lack what feature that makes it difficult to track down the cause of an
alarm?


A. Color-coding of their activation thresholds
B. Wide spaced combs
C. Visual triggers that tell which device was activated

D. Narrow spaced combs - ANS C. Visual triggers that tell which device was activated


In a cross-zoned smoke detection system, what must happen after the activation of a detector
before the actual alarm will sound?


A. A second detector must activate.

, ©EVERLY 2025 ALL RIGHTS RESERVED


B. A human must manually activate the alarm.
C. The detector must continue reverting to alarm after three attempts at auto-reset.

D. A sprinkler head must also be activated and flow water. - ANS A. A second detector must
activate.


What type of fire alarm annunciation system identifies the zone in which the alarm was
initiated both at the alarm control panel and through the audio notification device?


A. Zoned
B. Wired
C. Coded

D. Central - ANS C. Coded


Which is one of the functions sprinkler heads perform?


A. Notify occupants of the fire
B. Auto-restore when the fire is out
C. Activate the system

D. Report any trouble in the system - ANS C. Activate the system


Where are the main sprinkler system valves usually installed?


A. Outside the building, coming up out of the ground, and then going back down underground
B. Outside the building, coming up out of the ground on a post
C. On the main riser, above the water supply control valve

D. On the main riser, below the water supply control valve - ANS C. On the main riser, above
the water supply control valve

, ©EVERLY 2025 ALL RIGHTS RESERVED


The preferred water source for a sprinkler system is a:
A. private pressure tank.
B. private non-pressure static supply.
C. elevated water supply cistern.

D. municipal water system. - ANS D. municipal water system


What does the W stand for in WPIV( ______ post indicator valve)?


A. Wall
B. Water
C. Waiting

D. Wrapped - ANS A. Wall


In a pre-action sprinkler system, what else must happen in addition to a head being activated
before water will flow?


A. The alarm condition must persist for a set time.
B. The preliminary mini-discharge must fail to put out the fire.
C. Some physical shock must have occurred to the system.

D. A secondary device must be activated. - ANS D. A secondary device must be activated.


The normal type of sprinkler system used where there is a risk of the system freezing is a


A. dry system.
C. residential system.
B. wet system.

D. COz system. - ANS A. dry system.
$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Everly Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
18
Miembro desde
1 año
Número de seguidores
1
Documentos
2796
Última venta
2 meses hace
Study packs.

Find Quality Exam Materials made by professionals With A guaranteed A+

4.3

4 reseñas

5
2
4
1
3
1
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes