1.To measure the strength of a welded joint what mechanical test would you prescribe?

a) A transverse weld tension test

b) A charpy test.

c) A CTOD test.

d) An all weld metal tension test. e) A side bend test. - ANSWER✔✔-a) A transverse
weld tension test

2. Select the cutting process that would provide the narrowest heat affected zone when
cutting 12.5 mm (0.5 in) thick carbon steel.

a) Oxy-acetylene cutting.

b) Air-carbon arc cutting.

c) Oxy-propane cutting.

d) Plasma arc cutting.

e) Laser beam cutting - ANSWER✔✔-e) Laser beam cutting

3. Which of the following refers to a welder test where a pipe assembly is placed
vertically and the joint welded in the horizontal position without rotating the assembly?

a) 1G

b) 2G

c) 3G




COPYRIGHT © 2025 BY OLIVIA WEST, ALL RIGHTS RESERVED 1

,d) 5G

e) 6G - ANSWER✔✔-b) 2G

4. Which of the following imperfections is normally considered as unacceptable
regardless of size or location?

a) Porosity.

b) Crack.

c) Inadequate penetration.

d) Lamination.

e) Burn-through. - ANSWER✔✔-b) Crack.

5. Select the correct penetrameter thickness for 2% sensitivity when radiographing a
weldment 1 .25 inches in thickness.

a) 0.012 in.

b) 0.015 in.

c) 0.025 in

d) 0.030 in. - ANSWER✔✔-c) 0.025 in

6. Which of the following statements concerning porosity is true?

a) Porosity cannot be trapped within a weld.

b) Porosity moves up through later passes and will show only in a final pass.

c) Porosity is restricted to the centre line of a weld.

d) Porosity can result from faulty welder technique.

e) Porosity can be dissipated by an appropriate heat treatment. - ANSWER✔✔-d)
Porosity can result from faulty welder technique.

7. An irregular, dense white spot is seen on the radiograph of a weld. Assuming it was
caused by the welding process used, which one of the processes below would be
responsible?

a) SMAW process.



COPYRIGHT © 2025 BY OLIVIA WEST, ALL RIGHTS RESERVED 2

,b) GTAW process.

c) GMAW process.

d) ST process.

e) ESW process. - ANSWER✔✔-b) GTAW process.

8. Which of the following operations is known to result in the emission of ionizing
radiation at levels dangerous to human health?

A) shield metal arc welding.

B) Plasma arc welding.

C) Operation of high voltage portable generator sets.

d) Radiographic inspection.

e) Electroslag and electrogas welding. - ANSWER✔✔-d) Radiographic inspection.

9. The ultrasonic transducer is pressed against the plate of a welded joint. The sound
travels

longitudinally through the plate to the opposite side. The signal seen on the UT screen
that comes from this opposite side of the plate:

a) Is the initial pulse signal.

b) Is the back reflection signal.

c) Is the front reflection signal.

d) Must be equal in amplitude to any defect signal.

e) Cannot be used for establishing the thickness of the material under test. -
ANSWER✔✔-b) Is the back reflection signal.

11. Which of the following is a stainless steel electrode?

a) E4918-1

b) E4918-A1

c) E4818

d) E308-16



COPYRIGHT © 2025 BY OLIVIA WEST, ALL RIGHTS RESERVED 3

, e) E4111 - ANSWER✔✔-d) E308-16

12. Reverse polarity refers to the use of a:

a) AC power source, electrode +

b) DC power source, electrode+

c) AC power source, electrode-

d) DC power source, electrode- - ANSWER✔✔-b) DC power source, electrode+

13. Which welding process(es) can result in metallic inclusions in the weld?

a) SMAW.

b) FCAW.

c) GMAW.

d) GTAW

e) SAW - ANSWER✔✔-d) GTAW

14. In producing a drawing for a scale of 1:50, what would be the distance represented
by a distance on the drawing of 6 em?

a) 12 em.

b) 30 em.

c) 50 em.

d) 240 em.

e) 300 em. - ANSWER✔✔-e) 300 em.

15. As a general rule, weld discontinuities detected by ultrasonic testing are accepted or
rejected on the basis of:

a) Vertical linearity.

b) Time base analysis.

c) Horizontal response data.

d) Noise to signal ratio.



COPYRIGHT © 2025 BY OLIVIA WEST, ALL RIGHTS RESERVED 4

Información del documento

Subido en
29 de abril de 2025
Número de páginas
32
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
OliviaWest
2.7
(23)
Vendido
119
Seguidores
17
Artículos
8422
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes