Examen

Fire Inspector Practice Exam

Document preview thumbnail
Vista previa 2 fuera de 5 páginas

Fire Inspector Practice Exam /. Which of the following is NOT considered to be a model code orgnization? A. National Fire Protection Association B. National Fire Academy C. International Code Counil D. American Society of Mechanical Engineers - Answer-B. National Fire Academy /.A prescriptive code does which of the following? A. List the specific details the installation or construction must meet B. Requires equipment to be installed for protection against a hazard C. Is intereted locally D. Is a national standard - Answer-A. List the specific details the installion or construction must meet /.What type of tanker typically transport 6,000 to 10,000 gallons of flammable and combustible materials? A. MC-306 Tanker B. MC-307 Tanker C. MC-312 Tanker D. MC-314 Tanker - Answer-A. MC-306 Tanker /.Railway tankers typically transport up to ____ gallons A. 25,000 B. 30,000 C. 35,000 D. 40,000 - Answer-B. 30,000 /.Which items should be a top priority when evaluating the building's fire protection features? A. Exit doors B. Fire alarm systems and automatic sprinkler systems C. HVAC D. Utility locations - Answer-v /.What is the minimum acceptable rating for fire extinguishers? A. 1A10BC B. 2A10BC C. ABCD D. 10A10BC - Answer-B. 2A10BC /.A frangible bulb sprinkler head with a temperature rating of 500-575 degrees would be what color? A. Black B. Orange C. Red D. Green - Answer-A. Black /.NFPA ____ is the standard on dry chemical extiguishing systems. A. 17 B. 25 C. 13 D. 55 - Answer-A. 17 /.How thick can wood posts in a heavy timber constructed building be? A. 2" B. 4" C. 6" D. 8" - Answer-D. 8" (20.3cm) /.NFPA ____ is the standard for fire safety and emergency sysmbols. A. 1 B. 10 C. 101 D. 170 - Answer-D. 170 /.How many sleeping accommodations are requires for an occupancy to be classified as a hotel? A. More than 4 B. More than 8 C. More than 12 D. More than 18 - Answer-C. More than 12 /.The ____ is that portion of a mess of egress that is between the exit access and exit discharge. A. Occupant load B. Exit C. Stairs

Vista previa del contenido

Fire Inspector Practice Exam


/. Which of the following is NOT considered to be a model code orgnization?

A. National Fire Protection Association
B. National Fire Academy
C. International Code Counil
D. American Society of Mechanical Engineers - Answer-B. National Fire Academy

/.A prescriptive code does which of the following?

A. List the specific details the installation or construction must meet
B. Requires equipment to be installed for protection against a hazard
C. Is intereted locally
D. Is a national standard - Answer-A. List the specific details the installion or
construction must meet

/.What type of tanker typically transport 6,000 to 10,000 gallons of flammable and
combustible materials?

A. MC-306 Tanker
B. MC-307 Tanker
C. MC-312 Tanker
D. MC-314 Tanker - Answer-A. MC-306 Tanker

/.Railway tankers typically transport up to ____ gallons

A. 25,000
B. 30,000
C. 35,000
D. 40,000 - Answer-B. 30,000

/.Which items should be a top priority when evaluating the building's fire protection
features?

A. Exit doors
B. Fire alarm systems and automatic sprinkler systems
C. HVAC
D. Utility locations - Answer-v

/.What is the minimum acceptable rating for fire extinguishers?

A. 1A10BC
B. 2A10BC

, C. ABCD
D. 10A10BC - Answer-B. 2A10BC

/.A frangible bulb sprinkler head with a temperature rating of 500-575 degrees would be
what color?

A. Black
B. Orange
C. Red
D. Green - Answer-A. Black

/.NFPA ____ is the standard on dry chemical extiguishing systems.

A. 17
B. 25
C. 13
D. 55 - Answer-A. 17

/.How thick can wood posts in a heavy timber constructed building be?

A. 2"
B. 4"
C. 6"
D. 8" - Answer-D. 8" (20.3cm)

/.NFPA ____ is the standard for fire safety and emergency sysmbols.

A. 1
B. 10
C. 101
D. 170 - Answer-D. 170

/.How many sleeping accommodations are requires for an occupancy to be classified as
a hotel?

A. More than 4
B. More than 8
C. More than 12
D. More than 18 - Answer-C. More than 12

/.The ____ is that portion of a mess of egress that is between the exit access and exit
discharge.

A. Occupant load
B. Exit
C. Stairs

Información del documento

Subido en
28 de abril de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Brainariam
3.4
(30)
Vendido
160
Seguidores
7
Artículos
8386
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes