HVAC JOURNEYMAN (OK & KY) EXAM TEST BANK
NEWEST 2025/2026 LATEST TESTING ACTUAL
EXAM WITH 300+ QUESTIONS AND CORRECT
DETAILED ANSWERS ALREADY GRADED A+ / OK
HVAC JOURNEYMAN TEST / KY HVAC
JOURNEYMAN EXAM (BRAND NEW)
What type of power operated hand tools requires specific training in the
operation of the particular tool in order to be allowed to operate them?
A- fuel powered tools
B- power actuated tools
C- hydraulic power tools
D- pneumatic power tools B- power actuated tools
Where a closet is designed for the installation of a clothes dryer, an opening
having an area of not less than __ square inches shall be provided in the closet
enclosure.
A- 125
B- 150
C- 200
D- 100 D- 100 (IMC - 504.6)
All of the following statements are true regarding causes go high noise while
servicing a commercial unit, WITH THE EXCEPTION OF:
,A- a squeaky bearing in the electric motor
B- low head pressure
C- pulleys that are out of line
D- the compressor pumping excess oilB- low head pressure
According to OSHA requirements, bagged materials stored on a job site shall be
stacked..
A- not more than 7 feet in height
B- by stepping back the layers and cross-keying the bags at least every 10 bags
high
C- in tiers no higher than 6 feet
D- within 10 feet of an exterior wall which does not extend above the top of the
stacked bags B- by stepping back the layers and cross-keying the bags at
least every 10 bags high
A deep vacuum is an evacuation method in which a technician uses a vacuum
pump (or the systems compressor) to pull a vacuum until no moisture or other
vapor remains in the system. If the compressor is used for this procedure, but
CANNOT produce a deep vacuum, which of the following would be the problem?
A- bad TXV
B- low refrigerant
C- leaky suction valve
D- leaky exhaust valve C- leaky suction valve
Use a duct slide rule to determine required round steel duct size for a sheet metal
duct system showing a pressure drop of 0.25 IWC, delivers 1,000CFM, has a total
effective length of 263 feet, and a friction rate of 0.095 IWC/100.
,A- 12 inch diameter
B- 10 inch diameter
C- 16 inch diameter
D- 14 inch diameter D- 14 inch diameter (ACCA Ductulator (duct slide rule)
align 0.095 on galvanized metal duct /w 1000CFM = 14" round duct. 14 inch
diameter)
What is the minimum required outdoor ventilation rate for a residence with three
bedrooms, the bathrooms, one kitchen, and a 133 square foot one-car garage?
(Assume continuous exhaust for kitchen and bathrooms.)
A- 115 CFM
B- 175 CFM
C- 225 CFM
D- 295 CFM C- 225CFM (IMC - TABLE 403.3.1.1
The Manual J specific heat formula used for changing the temperature is
CFM=BTUh/(1.08 x Change Temperature). Therefore, what would be the required
heat input in BTUs to raise air quantity of 120CFM from the cold temperature of
30 deg F to a warm temperature of 80 deg F (without and altitude correction
factor)?
A- 8573 BTUh
B- 7824 BTUh
C- 6660 BTUh
D- 5231 BTUh C- 6660 BTUh (BTUh= 120CFM x 50deg F x 1.08 = 6480BTUh)
According to OSHA, upper and lower guards shall be equipped on...
A- grinding machines
, B- portable, power-driven circular saws
C- hand-fed crosscut table saws
D- hand-fed ripsaws B- portable, power-driven circular saws
In a residential building, the minimum wall thickness of an 8-inch round aluminum
duct must be what minimum gauge thickness?
A- 24
B- 26
C- 28
D- 30 A- 24 (IMC - TABLE 603.4 lists the required aluminum thickness of 0.018
inches minimum, for a round duct less than 12 inches diameter. A standard
sheet metal thickness gauge table will list the thickness of 24 gauge aluminum
as 0.0201 inches, and the thickness of 26 gauge aluminum as 0.0159 inches (too
thin). Correct multiple choice answer is 24 gauge aluminum duct (0.0201
inches).
Carbon steel pipe with a wall thickness not less than __ shall be used for Group A1
refrigerant liquid lines 6 inches and smaller.
A- FMT
B- EMT
C- Schedule 40
D- Schedule 80 C- Schedule 40 (IMC - 1107.5.1)
A plumbing vent outlet is discharging 2 feet above a forced- warm- air furnace
outside air inlet. What is the minimum distance that the outside air inlet shall be
from the vent outlet?
A- 12 feet
NEWEST 2025/2026 LATEST TESTING ACTUAL
EXAM WITH 300+ QUESTIONS AND CORRECT
DETAILED ANSWERS ALREADY GRADED A+ / OK
HVAC JOURNEYMAN TEST / KY HVAC
JOURNEYMAN EXAM (BRAND NEW)
What type of power operated hand tools requires specific training in the
operation of the particular tool in order to be allowed to operate them?
A- fuel powered tools
B- power actuated tools
C- hydraulic power tools
D- pneumatic power tools B- power actuated tools
Where a closet is designed for the installation of a clothes dryer, an opening
having an area of not less than __ square inches shall be provided in the closet
enclosure.
A- 125
B- 150
C- 200
D- 100 D- 100 (IMC - 504.6)
All of the following statements are true regarding causes go high noise while
servicing a commercial unit, WITH THE EXCEPTION OF:
,A- a squeaky bearing in the electric motor
B- low head pressure
C- pulleys that are out of line
D- the compressor pumping excess oilB- low head pressure
According to OSHA requirements, bagged materials stored on a job site shall be
stacked..
A- not more than 7 feet in height
B- by stepping back the layers and cross-keying the bags at least every 10 bags
high
C- in tiers no higher than 6 feet
D- within 10 feet of an exterior wall which does not extend above the top of the
stacked bags B- by stepping back the layers and cross-keying the bags at
least every 10 bags high
A deep vacuum is an evacuation method in which a technician uses a vacuum
pump (or the systems compressor) to pull a vacuum until no moisture or other
vapor remains in the system. If the compressor is used for this procedure, but
CANNOT produce a deep vacuum, which of the following would be the problem?
A- bad TXV
B- low refrigerant
C- leaky suction valve
D- leaky exhaust valve C- leaky suction valve
Use a duct slide rule to determine required round steel duct size for a sheet metal
duct system showing a pressure drop of 0.25 IWC, delivers 1,000CFM, has a total
effective length of 263 feet, and a friction rate of 0.095 IWC/100.
,A- 12 inch diameter
B- 10 inch diameter
C- 16 inch diameter
D- 14 inch diameter D- 14 inch diameter (ACCA Ductulator (duct slide rule)
align 0.095 on galvanized metal duct /w 1000CFM = 14" round duct. 14 inch
diameter)
What is the minimum required outdoor ventilation rate for a residence with three
bedrooms, the bathrooms, one kitchen, and a 133 square foot one-car garage?
(Assume continuous exhaust for kitchen and bathrooms.)
A- 115 CFM
B- 175 CFM
C- 225 CFM
D- 295 CFM C- 225CFM (IMC - TABLE 403.3.1.1
The Manual J specific heat formula used for changing the temperature is
CFM=BTUh/(1.08 x Change Temperature). Therefore, what would be the required
heat input in BTUs to raise air quantity of 120CFM from the cold temperature of
30 deg F to a warm temperature of 80 deg F (without and altitude correction
factor)?
A- 8573 BTUh
B- 7824 BTUh
C- 6660 BTUh
D- 5231 BTUh C- 6660 BTUh (BTUh= 120CFM x 50deg F x 1.08 = 6480BTUh)
According to OSHA, upper and lower guards shall be equipped on...
A- grinding machines
, B- portable, power-driven circular saws
C- hand-fed crosscut table saws
D- hand-fed ripsaws B- portable, power-driven circular saws
In a residential building, the minimum wall thickness of an 8-inch round aluminum
duct must be what minimum gauge thickness?
A- 24
B- 26
C- 28
D- 30 A- 24 (IMC - TABLE 603.4 lists the required aluminum thickness of 0.018
inches minimum, for a round duct less than 12 inches diameter. A standard
sheet metal thickness gauge table will list the thickness of 24 gauge aluminum
as 0.0201 inches, and the thickness of 26 gauge aluminum as 0.0159 inches (too
thin). Correct multiple choice answer is 24 gauge aluminum duct (0.0201
inches).
Carbon steel pipe with a wall thickness not less than __ shall be used for Group A1
refrigerant liquid lines 6 inches and smaller.
A- FMT
B- EMT
C- Schedule 40
D- Schedule 80 C- Schedule 40 (IMC - 1107.5.1)
A plumbing vent outlet is discharging 2 feet above a forced- warm- air furnace
outside air inlet. What is the minimum distance that the outside air inlet shall be
from the vent outlet?
A- 12 feet