'/*' to begin comment and '*/' to end comment Correct Answers
how are multi line comments indicated
1 Correct Answers degrees of freedom of revolute and
prismatic joints
2 components of biological tissues Correct Answers visoelastic
and non linear (toe region)
3 standard planes for medical imaging Correct Answers
sagittal, coronal, axial/transverse
3d printing Correct Answers additive manufacturing, building
wall/icing a cake
3d scanners Correct Answers multi-camera, where cameras are
usually fixed positions to simplify calibration and image
correction processes, huge range in price and precision, include
process like
1. point cloud
2. mesh
4 major classes of biomaterials Correct Answers 1. polymers
2. metals
3. ceramics
4. natural
,a capacitor Correct Answers store energy electrostatically,
generally composed of two conducting plates separated by
dielectric material, depends on area/spacing/dielectric material
a medical device Correct Answers diagnoses, cures, lessens,
treats or prevents human disease-affects the function or structure
of the body-does not achieve primary intended purpose through
chemical action
a semicolon Correct Answers what character ends most lines in
an arduino program?
a sensor Correct Answers a device that detects or measures a
physical property and records, indicates, or otherwise responds
to it
actuators Correct Answers convert energy into motion
aliasing Correct Answers when for example, we didn't sample
at a high enough rate and estimated a much lower frequency
allocation Correct Answers (how participants are assigned to
different groups
)randomized common into arms
an assay Correct Answers an investigative procedure for
qualitatively assessing or quantitatively measure the presence,
amount or functional activity of a target
analyte, detector/transducer, signal, analysis, response Correct
Answers components of biochemical biosensor
, axial plane Correct Answers A horizontal flat surface dividing
the body into upper and lower parts; also known as the
transverse plane
Battery Correct Answers what component can be used to
model the membrane's resting potential?
bioacoustics Correct Answers ultrasound biosignal
biochemical Correct Answers blood glucose monitor biosignal
bioelectric Correct Answers EEG sensor biosignal
bioimpedance Correct Answers GSR sensor biosignal
biomagnetic Correct Answers mri biosignal
biomechanical Correct Answers respiration monitor belt
biosignal
biomechanics Correct Answers branch of mechanics dealing
with motion and forces producing motion in biological and
biomedical objects
biomedical imaging Correct Answers study of medical imaging
is concerned with the interactions of all forms of radiation with
tissue, the development of appropriate technology to extract
clinically useful information, usually in the form of an image
from the observed technology