100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NATE Heat Pump Exam Questions with Correct Solutions, A+

Puntuación
-
Vendido
-
Páginas
24
Grado
A+
Subido en
14-04-2025
Escrito en
2024/2025

A technician places a heat pump into the auxiliary electric heating mode with the compressor de-energized. He measures a temperature rise between the return and supply air of 40 degrees. The measured voltage at the electric elements is exactly 222 volts and the measured amperage of the heaters is 60 amps. Using the equation CFM = BTU divided by 1.08 x TD, what is the CFM of the system? A: 825 CFM B: 950 CFM C: 1055 CFM D: 1500 CFM - Correct Solution C: 1055 CFM 222 x 60 = 13,320watts 13,320 / 1000 = 13.32 Kw btuh = 13.32 x 3415 = 45,488 cfm =((45,488 / (1.08 x 40)) cfm = 45,488 / 43.2 = 1052.95 Solid state defrost control boards can be adjusted to: A: Program the thermostat from outside the house B: Change the frequency of defrosts C: Control the speed of the outdoor fan during defrost D: Control the speed of the indoor fan during defrost - Correct Solution B: Change the frequency of defrosts A thermistor is an: A: Electronic temperature sensor that changes its resistance with changes in temperature B: Electronic pressure sensor that changes its resistance with changes in pressure C: Electromechanical thermostat used to terminate the defrost cycle when outdoor coil is clear of ice and frost D: None of these is correct - Correct Solution A: Electronic temperature sensor that changes its resistance with changes in temperature The correct way to size a heat pump is to perform both heating and cooling load calculations and select the heat pump size by: A: Adding the heating load and cooling loads B: Subtracting the smaller load from the larger load C: Using the heating load to size the system D: Using the cooling load to size the system - Correct Solution D: Using the cooling load to size the system Auxiliary electric heat is necessary because: A: It provides heat for the home during defrosts B: It provides heat for the home in the event of a heat pump failure C: It provides heat for the home if the heat pump is unable to meet the demand for heat D: All of the above - Correct Solution D: All of the above Reading a voltage across the contacts of the outdoor thermostat means: A: The thermostat contacts are closed B: The thermostat contacts are open C: The thermostat contacts are stuck D: The thermostat contacts are working correctly - Correct Solution B: The thermostat contacts are open Which of the following is not a type of heat pump? A: Ground to air B: Air to air C: Water to air D: Direct coupled - Correct Solution D: Direct coupled The coefficient of performance is determined by: A: Dividing the output btuh by the input btuh B: Dividing the input btuh by the output btuh C: Multiplying the input by the output D: Subtracting the output from the input - Correct Solution B: Dividing the input btuh by the output btuh The coefficient of performance or COP of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work required. Higher COPs equate to higher efficiency. The "balance point" of a heat pump is: A: The lowest temperature at which the heat pump can meet the heating requirement for the structure B: The lowest temperature at which the heat pump can operate C: The temperature at which the heat pump has the highest efficiency D: The point at which the heating and cooling loads meet - Correct Solution A: The lowest temperature at which the heat pump can meet the heating requirement for the structure Which of the following is an incorrect term for the solenoid valve that switches the heat pump between the heating and cooling modes? A: Changeover valve B: Reversing valve C: Four-way valve D: Discharge operator valve - Correct Solution D: Discharge operator valve The best location for the outdoor section of an air to air heat pump is: A: Where it gets the winter sun B: Where it is sheltered from the sun's radiation C: Where it never snows D: Under the shelter of a porch - Correct Solution A: Where it gets the winter sun What may happen if the body of a reversing valve is slightly dented? A: Nothing, as they are made to be very durable B: The internal slide may stick C: The valve may make noises from the gas trying to pass through partially open ports D: Both b and c are correct - Correct Solution D: Both b and c are correct

Mostrar más Leer menos
Institución
Nate Heat Pump Service
Grado
Nate heat pump service










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Nate heat pump service
Grado
Nate heat pump service

Información del documento

Subido en
14 de abril de 2025
Número de páginas
24
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Vista previa del contenido

NATE Heat
Pump Exam
Questions with
Correct
Solutions, A+

,A technician places a heat pump into the auxiliary electric heating mode with the
compressor de-energized. He measures a temperature rise between the return and
supply air of 40 degrees. The measured voltage at the electric elements is exactly
222 volts and the measured amperage of the heaters is 60 amps. Using the equation
CFM = BTU divided by 1.08 x TD, what is the CFM of the system?


A: 825 CFM
B: 950 CFM
C: 1055 CFM
D: 1500 CFM - Correct Solution C: 1055 CFM

, 222 x 60 = 13,320watts
13, = 13.32 Kw
btuh = 13.32 x 3415 = 45,488
cfm =((45,488 / (1.08 x 40))
cfm = 45,.2 = 1052.95


Solid state defrost control boards can be adjusted to:


A: Program the thermostat from outside the house


B: Change the frequency of defrosts


C: Control the speed of the outdoor fan during defrost


D: Control the speed of the indoor fan during defrost - Correct Solution B:
Change the frequency of defrosts
A thermistor is an:


A: Electronic temperature sensor that changes its resistance with changes in
temperature


B: Electronic pressure sensor that changes its resistance with changes in pressure


C: Electromechanical thermostat used to terminate the defrost cycle when outdoor
coil is clear of ice and frost
$15.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TeeGrades Louisiana State University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
195
Miembro desde
3 año
Número de seguidores
125
Documentos
5350
Última venta
1 mes hace
TeeGrades

Unlock Your Academic Success with Exceptional Study Materials Are you tired of spending endless hours searching for reliable study materials to enhance your academic performance? Look no further! Contact us for any study materials (notes, examinations, and test banks)! Please take a moment to provide a rating for the document if you found it helpful. Your feedback helps us improve our services and assists others in finding valuable information. TIA

Lee mas Leer menos
3.5

52 reseñas

5
19
4
5
3
19
2
3
1
6

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes