• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 15 páginas
Examen

HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE

Document preview thumbnail
Vista previa 2 fuera de 15 páginas

HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE

Vista previa del contenido

HVAC JOURNEYMAN EXAM AND PRACTICE EXAM QUESTIONS AND CORRECT DETAILED
ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE










Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C)
repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. -
(ANSWER)B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3



Every absorption refrigerating system supported from the ground shall rest on a concrete slab extending
not less than _____ the adjoining ground level.(A) 3 inches below(B) 3 inches above (C) 6 inches
below(D) 6 inches above. -(ANSWER)B. Slab extending not less than 3" above the adjoining ground level.
UMC Section 1106.2



Any part of a venting system installed at an angle greater than 45 degrees from the vertical is considered
by code to be _____.(A) vertica(B) horizontal l (C) a flat vent (D) an offset vent -(ANSWER)B. any part of
the venting installed at an angle GREATER than 45 degrees is considered by this code to be Horizontal
UMC Section 802.6.1.1



Listed transition ducts f or clothes dryers shall not exceed_____ feet in length. A.3 B.4 C.5 D.6. -
(ANSWER)D. Dryers shall not exceed 6 feet in length. UMC Section 504.3.2.1



Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid materials
shall be constructed of _____.(A) sheet meta(B) polyvinyl chloride l (C) fiberglass (D) A and C apply -
(ANSWER)A. Shall Be Constructed of sheet metal. UMC Section. 5 0 6.1



Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid materials
shall be constructed of _____.(A) sheet metal ((B) polyvinyl chloride C) fiberglass (D) A and C apply -
(ANSWER)A 511.2



Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less than _____ inches.
Is the Answer: A. 10" B. 12" C 16" D. 18". -(ANSWER)D. clearance of an unlisted vented gas fireplace at
the sides and the rear not less than 18". UMC Section 908.2(B)

, HVAC JOURNEYMAN EXAM AND PRACTICE EXAM QUESTIONS AND CORRECT DETAILED
ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE










Leaks in gas piping shall be located _____.(A) with a sniffer(B) with a presto-lite flame (C) with a
noncorrosive leak-detecting fluid (D) by increasing the air pressure during a test until the leaks are heard
as a whistle. -(ANSWER)C. leaks in a gas piping shall be located with a non corrosive leak detecting fluid.
UMC Section 1316.4.2



Condensate drain piping shall have a slope of not less than _____ inch per foot. A 1⁄8" B.¼" C.½" D. 1" -
(ANSWER)A. Slope of not less than 1/8" per foot. UMC Section 309.1



The minimum gauge or size steel wire used to support horizontal metal ducts 10 inches or less in size is
_____. A.14 AWG B.16 AWG C.18 AWG D.20 AWG -(ANSWER)C. 18 Minimum Gauge note: AWG is the
abbreviation for "gauge size" Table 6-7(B)



When smoke detectors are required as part of an automatic shutoff system, they shall be installed in the
_____. A. return air duct ahead of any fresh-air inlet(B) main supply air duct served by such
equipment(C) fresh-air inlet(D) main return and the main supply duct. -(ANSWER)B. shall be installed in
the main supply air duct served by equipment. UMC Section 609.0(5)



The largest fuel-burning appliance allowed in a room 100'W x 20'L x 8'H without combustion air
openingsis _____ Btu.(A) 80,000 (C) 140,000(B) 100,000 (D) 320,000 -(ANSWER)31 D. 701.2.1



Return air ducts that serve a dwelling unit shall be permitted to be of _____ construction? A.non-
combustible B. combustible C. rated D. none of the above. -(ANSWER)B. Shall be permitted to be of
combustible type UMC Section 602.2 Ex (1)



Solid fuel-burning appliances _____ be connected to a venting system that serves a gas- or oil-
burningappliance.(A) shall (B) may (C) shall not(D) with special approval may -(ANSWER)C. appliances
shall not UMC Section 802.5.5.1

Información del documento

Subido en
28 de marzo de 2025
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$21.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
CourseNinja
5.0
(1011)
Vendido
7473
Seguidores
7
Artículos
2445
Última venta
6 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes