HVAC JOURNEYMAN TEST 2025/2026 COMPLETE QUESTIONS WITH VERIFIED CORRECT SOLUTIONS || 100% GUARANTEED PASS LATEST VERSION 1. Any joint obtained by joining of metal parts with alloys that melt at temperatures higher than 840°F, but lowerthan the melting temperature of the parts to be joined, is a _____ joint.(A) brazed(B) fused (D) soldered (C) welded - ANSWER A. Is a brazed joint UMC section 2 1 2.0 2. A vessel or arrangement of piping or tubing in which vaporized refrigerant is liquefied by removal of heat is a _____.(A) compressor (C) evaporator(B) generator (D) condenser - ANSWER D. A condenser is the piping which vaporizes the refrigerant liquefied by removal of heat, UMC Section 2 0 5.0 3. is a _____.(A) compressor (C) evaporator(B) generator (D) condenser - ANSWER 18 D 502.0 4. An appliance designed primarily to supply hot water equipped with automatic controls limiting water - ANSWER B 1201.2.1.8 5. temperature to a maximum of 210°F is a _____.(A) water heater (C) expansion tank(B) steam boiler (D) gas heater. - ANSWER A 507.1.3 6. A cooling coil is to be installed in a duct system containing an existing furnace heat exchanger. Unless - ANSWER C 907.1 7. otherwise listed, the code requires that the air flows first through _____.(A) the heat exchanger (C) a diverter unit(B) the cooling coil (D) a bypass duct - ANSWER C 903.5 8. The space in which any floor furnace is installed shall be accessible by an opening in the foundation not - ANSWER B 1312.3.2 9. less than _____.(A) 24'' x 24'' (C) 20'' x 20''(B) 24'' x 18'' (D) none of the above - ANSWER C 507.2.1 10. ... - ANSWER B 510.7.5 11. Buildings of more than _____ feet in height shall have an inside means of access to the roof.(A) 14 (C) 15 (B) 16 (D) 20 - ANSWER C 701.1 12. The compressor should be on a level pad _____ inches above grade. - ANSWER 3 13. The electrical disconnect should be in direct line of sight and no more than ____ feet away from the compressor/condenser cabinet. - ANSWER 50 14. Insulation is wrapped around the: - ANSWER suction line 15. Frost on the evaporator coil indicates? - ANSWER The unit should be shutdown 16. Opening the condenser cabinet to get at the compressor is beyond the "Texas Standards of Practice". - ANSWER true 17. Common evaporator coil problems include all the following except? Dirt, Frost, Radiant burn, Corrosion - ANSWER radiant burn 18. All coils corrode as they age, and as long as there is not a significant reduction of heat transfer or airflow, this is not a major problem. - ANSWER true 19. A three-ton air conditioner will generate about ____ gallons of condensate per hour on a hot humid summer day. - ANSWER 2 20. Drain piping for air conditioning equipment shall be a minimum of _____ inch(es) nominal pipe size. - ANSWER 3/4 21. The _____ is the heart of the air conditioning system. - ANSWER compressor 22. In rooms with supply registers, only the doors should be undercut at least _____ of an inch to allow air to reach the return registers. - ANSWER 3/4 23. Reduced air flow can increase the amount of dirt in the air. - ANSWER true 24. Our "Texas Standards of Practice" require us to perform a detailed duct system inspection. - ANSWER false Sensible Heat - ANSWER Heat that can be Measured 25. Specific Heat - ANSWER The Amount of Heat Required to Raise 1 LB of a Substance 1*F 26. Latent Heat - ANSWER Heat used to cause change of state. 27. BTU - ANSWER amount of heat required to raise 1LB of water 1*F 28. One Ton of Refrigeration - ANSWER 2000 x 144 x 24,288,000 Btu/24hours, and 12,000 Btu/hr 29. A Room Thermostat Should be Mounted - ANSWER 5 feet from the floor 30. To Provide Proper Oil Return to the Compressor - ANSWER Suction line must be pitched towards compressor. 31. What is the External Equalizer on a TXV for? - ANSWER To offset the pressure drop across the evaporator.

Vista previa del contenido

HVAC JOURNEYMAN TEST 2025/2026
COMPLETE QUESTIONS WITH
VERIFIED CORRECT SOLUTIONS ||
100% GUARANTEED PASS
<LATEST VERSION>


1. Any joint obtained by joining of metal parts with alloys that melt at
temperatures higher than 840°F, but lowerthan the melting temperature of
the parts to be joined, is a _____ joint.(A) brazed(B) fused (D) soldered (C)
welded - ANSWER ✓ A. Is a brazed joint UMC section 2 1 2.0

2. A vessel or arrangement of piping or tubing in which vaporized refrigerant is
liquefied by removal of heat is a _____.(A) compressor (C) evaporator(B)
generator (D) condenser - ANSWER ✓ D. A condenser is the piping which
vaporizes the refrigerant liquefied by removal of heat, UMC Section 2 0 5.0

3. is a _____.(A) compressor (C) evaporator(B) generator (D) condenser -
ANSWER ✓ 18 D 502.0


4. An appliance designed primarily to supply hot water equipped with
automatic controls limiting water - ANSWER ✓ B 1201.2.1.8

5. temperature to a maximum of 210°F is a _____.(A) water heater (C)
expansion tank(B) steam boiler (D) gas heater. - ANSWER ✓ A 507.1.3


6. A cooling coil is to be installed in a duct system containing an existing
furnace heat exchanger. Unless - ANSWER ✓ C 907.1

,7. otherwise listed, the code requires that the air flows first through _____.(A)
the heat exchanger (C) a diverter unit(B) the cooling coil (D) a bypass duct -
ANSWER ✓ C 903.5


8. The space in which any floor furnace is installed shall be accessible by an
opening in the foundation not - ANSWER ✓B 1312.3.2

9. less than _____.(A) 24'' x 24'' (C) 20'' x 20''(B) 24'' x 18'' (D) none of the
above - ANSWER ✓ C 507.2.1

10.... - ANSWER ✓ B 510.7.5

11.Buildings of more than _____ feet in height shall have an inside means of
access to the roof.(A) 14 (C) 15 (B) 16 (D) 20 - ANSWER ✓ C 701.1

12.The compressor should be on a level pad _____ inches above grade. -
ANSWER ✓ 3

13.The electrical disconnect should be in direct line of sight and no more than
____ feet away from the compressor/condenser cabinet. - ANSWER ✓ 50

14.Insulation is wrapped around the: - ANSWER ✓ suction line

15.Frost on the evaporator coil indicates? - ANSWER ✓ The unit should be
shutdown

16.Opening the condenser cabinet to get at the compressor is beyond the "Texas
Standards of Practice". - ANSWER ✓ true

17.Common evaporator coil problems include all the following except?
Dirt, Frost, Radiant burn, Corrosion - ANSWER ✓ radiant burn

18.All coils corrode as they age, and as long as there is not a significant
reduction of heat transfer or airflow, this is not a major problem. - ANSWER
✓ true

, 19.A three-ton air conditioner will generate about ____ gallons of condensate
per hour on a hot humid summer day. - ANSWER ✓ 2

20.Drain piping for air conditioning equipment shall be a minimum of _____
inch(es) nominal pipe size. - ANSWER ✓ 3/4

21.The _____ is the heart of the air conditioning system. - ANSWER ✓
compressor

22.In rooms with supply registers, only the doors should be undercut at least
_____ of an inch to allow air to reach the return registers. - ANSWER ✓ 3/4

23.Reduced air flow can increase the amount of dirt in the air. - ANSWER ✓
true

24.Our "Texas Standards of Practice" require us to perform a detailed duct
system inspection. - ANSWER ✓ false
Sensible Heat - ANSWER ✓ Heat that can be Measured

25.Specific Heat - ANSWER ✓ The Amount of Heat Required to Raise 1 LB of
a Substance 1*F

26.Latent Heat - ANSWER ✓ Heat used to cause change of state.

27.BTU - ANSWER ✓ amount of heat required to raise 1LB of water 1*F

28.One Ton of Refrigeration - ANSWER ✓ 2000 x 144 x 24,288,000
Btu/24hours, and 12,000 Btu/hr

29.A Room Thermostat Should be Mounted - ANSWER ✓ 5 feet from the floor

30.To Provide Proper Oil Return to the Compressor - ANSWER ✓ Suction line
must be pitched towards compressor.

31.What is the External Equalizer on a TXV for? - ANSWER ✓ To offset the
pressure drop across the evaporator.

Información del documento

Subido en
16 de marzo de 2025
Número de páginas
24
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ProfBenjamin
3.7
(153)
Vendido
774
Seguidores
19
Artículos
4034
Última venta
22 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes