Type of sealant you should you use on a Phil-Tite Ball Float nipple: Correct
Answer - Pipe dope

Number of open valves on the clean air separator: Correct Answer - One

You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or
False? Correct Answer - False

The type of pressure gauge is recommended to test Healy Vac Correct
Answer - SYSA gauge measuring 0-100 WC

On new construction, after July 1, 2004, Can you install an in-ground Spill
Bucket? Correct Answer - YES-When Piping is monitored and with VAC

According to Executive Order 201 - Healy P/V Valve should be torqued at
Correct Answer - 20-50 ft-lbs

For a fire to burn, these (3) three primary elements must exist: Correct
Answer - Fuel, Oxygen, Ignition Source

When working with Electrical - Lock Out Tag Out procedures are under these
guidelines. Correct Answer - CAL-OSHA

Organization that certifies vapor recovery systems. Correct Answer -
CARB or ARB

According to RP 500, a level II technician may NOT inspect this part.
Correct Answer - Replace VP 1000 Healy Pump

where hanging hardware repairs must be tracked. Correct Answer - GDF
maintenance log

approved sealant when assembling a Phil-Tite Drop Tube. Correct Answer -
JB-Kwik

, Material direct bury OPW container sleeve shall be made of. Correct
Answer - Stainless steel

What P/V vent cap shall be tightened to. Correct Answer - 20-50 ft lbs

From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From
manifold to tank - 3" diameter vapor piping (3" ID) Correct Answer -
Vapor piping

What is the maximum run for vapor piping? Correct Answer - No
maximum run

How you know a nozzle spout is bad. Correct Answer - 'BAD O-rinqs

According to PEI RP 300, on a balance Stage II vapor recovery system nozzle,
Vapors typically flow in what direction of the coaxial hose? Correct Answer
- The outside pathway

What is the maximum allowable number of P/V caps allowed on a UST fuel
system? Correct Answer - One

On a Healy Air Separator, there are four Ball Valves, the following shall be
observed? Correct Answer - One valve shall remain open on top

The Pressure settings for the UST Vent Cap is. Correct Answer - .0+-
0.5inches H2O Negative Pressure 1,0+-2.0 inches H2O Positive Pressure

Given that in a balance Stage II vapor recovery system, the nozzle is equipped
with a flexible nozzle bellows that seals around the automobile fill pipe. This is
how vapors will typically flow. Correct Answer - From the outside
pathway of the coaxial hose

The Healy 1301 flow limiter shall be used when the flow rate exceeds this.
Correct Answer - 10.0 GPM

Given that: The VP1000 vacuum pump motor will operate automatically when
the temperature drops. The VP1000 will automatically operate when the
temperature drops below this temperature. Correct Answer - 40 f (35f if
40f is not an option)

Información del documento

Subido en
13 de marzo de 2025
Número de páginas
10
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NorthWest
4.1
(174)
Vendido
847
Seguidores
673
Artículos
6771
Última venta
4 semanas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes