• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 7 páginas
Examen

ICC Vapor Recovery - VT Test Questions with Correct Answers Graded A+

Document preview thumbnail
Vista previa 2 fuera de 7 páginas

ICC Vapor Recovery - VT Test Questions with Correct Answers Graded A+ Type of sealant you should you use on a Phil-Tite Ball Float nipple: - Answers Pipe dope Number of open valves on the clean air separator: - Answers One You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or False? - Answers False The type of pressure gauge is recommended to test Healy Vac - Answers SYSA gauge measuring 0-100 WC On new construction, after July 1, 2004, Can you install an in-ground Spill Bucket? - Answers YES-When Piping is monitored and with VAC According to Executive Order 201 - Healy P/V Valve should be torqued at - Answers 20-50 ft-lbs For a fire to burn, these (3) three primary elements must exist: - Answers Fuel, Oxygen, Ignition Source When working with Electrical - Lock Out Tag Out procedures are under these guidelines. - Answers CAL-OSHA Organization that certifies vapor recovery systems. - Answers CARB or ARB According to RP 500, a level II technician may NOT inspect this part. - Answers Replace VP 1000 Healy Pump where hanging hardware repairs must be tracked. - Answers GDF maintenance log approved sealant when assembling a Phil-Tite Drop Tube. - Answers JB-Kwik Material direct bury OPW container sleeve shall be made of. - Answers Stainless steel What P/V vent cap shall be tightened to. - Answers 20-50 ft lbs From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From manifold to tank - 3" diameter vapor piping (3" ID) - Answers Vapor piping What is the maximum run for vapor piping? - Answers No maximum run How you know a nozzle spout is bad. - Answers 'BAD O-rinqs According to PEI RP 300, on a balance Stage II vapor recovery system nozzle, Vapors typically flow in what direction of the coaxial hose? - Answers The outside pathway What is the maximum allowable number of P/V caps allowed on a UST fuel system? - Answers One On a Healy Air Separator, there are four Ball Valves, the following shall be observed? - Answers One valve shall remain open on top The Pressure settings for the UST Vent Cap is. - Answers .0+- 0.5inches H2O Negative Pressure 1,0+-2.0 inches H2O Positive Pressure Given that in a balance Stage II vapor recovery system, the nozzle is equipped with a flexible nozzle bellows that seals around the automobile fill pipe. This is how vapors will typically flow. - Answers From the outside pathway of the coaxial hose The Healy 1301 flow limiter shall be used when the flow rate exceeds this. - Answers 10.0 GPM Given that: The VP1000 vacuum pump motor will operate automatically when the temperature drops. The VP1000 will automatically operate when the temperature drops below this temperature. - Answers 40 f (35f if 40f is not an option) How do you verify a nozzle spout is bad and needs to be replaced? - Answers Test the nozzle Given that a "Classified Area" is a located where a fire and explosion hazard exists due to the presence of fuel vapors. Because vapors are heavier than air In a Class I, Division 2 area, where may vapors be present - Answers Extending 20 feet from dispensers to a height of 1.5 feet above ground absorbent pads, and absorbent boom, fuel absorbet material - Answers When responding to Fuel Spills, it is advisable to have the following equipment.

Vista previa del contenido

ICC Vapor Recovery - VT Test Questions with Correct Answers Graded A+

Type of sealant you should you use on a Phil-Tite Ball Float nipple: - Answers Pipe dope

Number of open valves on the clean air separator: - Answers One

You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or False? - Answers False

The type of pressure gauge is recommended to test Healy Vac - Answers SYSA gauge measuring 0-100
WC

On new construction, after July 1, 2004, Can you install an in-ground Spill Bucket? - Answers YES-When
Piping is monitored and with VAC

According to Executive Order 201 - Healy P/V Valve should be torqued at - Answers 20-50 ft-lbs

For a fire to burn, these (3) three primary elements must exist: - Answers Fuel, Oxygen, Ignition Source

When working with Electrical - Lock Out Tag Out procedures are under these guidelines. - Answers CAL-
OSHA

Organization that certifies vapor recovery systems. - Answers CARB or ARB

According to RP 500, a level II technician may NOT inspect this part. - Answers Replace VP 1000 Healy
Pump

where hanging hardware repairs must be tracked. - Answers GDF maintenance log

approved sealant when assembling a Phil-Tite Drop Tube. - Answers JB-Kwik

Material direct bury OPW container sleeve shall be made of. - Answers Stainless steel

What P/V vent cap shall be tightened to. - Answers 20-50 ft lbs

From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From manifold to tank - 3" diameter
vapor piping (3" ID) - Answers Vapor piping

What is the maximum run for vapor piping? - Answers No maximum run

How you know a nozzle spout is bad. - Answers 'BAD O-rinqs

According to PEI RP 300, on a balance Stage II vapor recovery system nozzle, Vapors typically flow in
what direction of the coaxial hose? - Answers The outside pathway

What is the maximum allowable number of P/V caps allowed on a UST fuel system? - Answers One

On a Healy Air Separator, there are four Ball Valves, the following shall be observed? - Answers One
valve shall remain open on top

, The Pressure settings for the UST Vent Cap is. - Answers .0+- 0.5inches H2O Negative Pressure 1,0+-2.0
inches H2O Positive Pressure

Given that in a balance Stage II vapor recovery system, the nozzle is equipped with a flexible nozzle
bellows that seals around the automobile fill pipe. This is how vapors will typically flow. - Answers From
the outside pathway of the coaxial hose

The Healy 1301 flow limiter shall be used when the flow rate exceeds this. - Answers 10.0 GPM

Given that: The VP1000 vacuum pump motor will operate automatically when the temperature drops.
The VP1000 will automatically operate when the temperature drops below this temperature. - Answers
40 f (35f if 40f is not an option)

How do you verify a nozzle spout is bad and needs to be replaced? - Answers Test the nozzle

Given that a "Classified Area" is a located where a fire and explosion hazard exists due to the presence
of fuel vapors. Because vapors are heavier than air In a Class I, Division 2 area, where may vapors be
present - Answers Extending 20 feet from dispensers to a height of 1.5 feet above ground

absorbent pads, and absorbent boom, fuel absorbet material - Answers When responding to Fuel Spills,
it is advisable to have the following equipment.

In accordance with PEI RP-500, a Level II Qualified Person may not perform what duty? - Answers
Replace a Healy VP1000 Pump

Volatile Organic Compounds - Answers VOC's

What does a Combustible-Gas Detector check for in Vapor Recovery Systems? - Answers Leaks/Vapors in
Vapor Recovery Systems {or LELor LFL 10% max)

8.0 +- 2.0, The P/V Cap has a black sticker with gold letters stating these positive/negative specs: -
Answers 3.0 +- 0.5

This is what connecting above ground vent lines together is called. - Answers Manifolding

Continuous monitoring which includes pressure (hydrostatic), vacuum in brine, was required after July 1,
2004 for which station components? - Answers Sumps and UDCs

The Healy VPl000 runs at a higher RPM under what circumstances? - Answers When both sides are
activated and nozzles are removed from the dispenser

Where is the Vapor valve located at? - Answers Under the dispenser (nozzle is second choice if dispenser
is not available)

When installing a ball float vent valve, what type of sealant shall you use? - Answers A gasoline resistant
compound

Información del documento

Subido en
12 de marzo de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorJosh
3.5
(77)
Vendido
508
Seguidores
16
Artículos
33052
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes