If your patient has a fenestrated canal you would have to do which of the following when taking ear impressions: a. Use large or multiple otoblocks b. use normal type of otoblock c. use normal type of otoblock, but with the X-type of string d. none of the above - Answer a. Use large or multiple otoblocks If your patient is using a device on their hearing aid to exclude room conversation but is able to hear on the telephone the hearing aid would have an: a. MPO switch b. MBO switch c. MTO switch d. MSO switch - Answer c. MTO switch The use of ototoxic drugs would be most likely cause: a. bilateral sensorineural hearing loss b. Meniere's disease c. otosclerosis d. cerebral vascular accident - Answer a. bilateral sensorineural hearing loss A man comes into your office and says that his hearing instrument is not working. During your inspection you find that it is not converting the electrical impulses into sound waves. Which part is not working: a. microphone b. receiver c. amplifier d. potentiometer - Answer b. receiver

Vista previa del contenido

Hearing Aid Dispenser Mock Exam 3 Study
Guide Questions And Actual Answers.
If your patient has a fenestrated canal you would have to do which of the following when taking ear
impressions:

a. Use large or multiple otoblocks

b. use normal type of otoblock

c. use normal type of otoblock, but with the X-type of string

d. none of the above - Answer a. Use large or multiple otoblocks



If your patient is using a device on their hearing aid to exclude room conversation but is able to hear on
the telephone the hearing aid would have an:

a. MPO switch

b. MBO switch

c. MTO switch

d. MSO switch - Answer c. MTO switch



The use of ototoxic drugs would be most likely cause:

a. bilateral sensorineural hearing loss

b. Meniere's disease

c. otosclerosis

d. cerebral vascular accident - Answer a. bilateral sensorineural hearing loss



A man comes into your office and says that his hearing instrument is not working. During your inspection
you find that it is not converting the electrical impulses into sound waves. Which part is not working:

a. microphone

b. receiver

c. amplifier

d. potentiometer - Answer b. receiver

,In doing speech testing, if I start 15 to 20 dB over the PTA which test would I most likely be doing:

a. UCL

b. MCL

c. SDT

d. SRT - Answer d. SRT



One test that is useful in determining the possibility of an acoustic neuroma is:

a. PB Max

b. SRT

c. PI-PB rollover

d. SAT - Answer c. PI-PB rollover



One cause of the receiver to quit working is:

a. the battery is only at 1.4v

b. the battery is of the zinc air type

c. external otitis

d. perforation of the tympanic membrane - Answer c. external otitis



If you have a patient with a pure tone air score of 45 dB with a pure tone bone score of 60 dB at 500 Hz
what could have caused it:

a. audiometer out of calibration

b. improper placement of bone oscillator

c. ambient noise

d. all of the above - Answer d. all of the above

audiometer out of calibration, improper placement of bone oscillator, ambient noise



Input compression would help which of the following hearing problems:

a. recruitment

, b. conductive component

c. normal hearing

d. conductive component in one ear and normal in the other - Answer a. recruitment



Tinnitus cannot be caused by which of the following:

a. smoking

b. stress

c. heavy dosages of aspirin

d. atresia - Answer d. atresia



If your patient has Meniere's syndrome, she would have which symptom:

a. coughing

b. vertigo

c. itching

d. all of the above - Answer b. vertigo



What test would you use to get the patients ear cavity volume and acoustic reflex:

a. impedance

b. real ear

c. impression

d. Short Increment Sensitivity Index (SISI) - Answer a. impedance



Which of the following is not used in determining retro cochlear problems:

a. Short Increment Sensitivity Index (SISI)

b. MCL

c. Acoustic Reflex Decay

d. Tone Decay Test - Answer b. MCL



Internal feedback in an ITE aid can be caused by:

Información del documento

Subido en
21 de febrero de 2025
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TestSolver9
3.6
(181)
Vendido
1017
Seguidores
131
Artículos
32175
Última venta
5 horas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes