100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ABRET (3) Exam Questions And Answers |Latest 2025 | Guaranteed Pass.

Puntuación
-
Vendido
-
Páginas
4
Grado
A+
Subido en
17-02-2025
Escrito en
2024/2025

©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:22PM. A+ 1 | P a g e ABRET (3) Exam Questions And Answers |Latest 2025 | Guaranteed Pass. What type of montage is shown in this sample? - AnswerReferential Montage Which montage would best display the amplitude of a left temporal spike? - AnswerLeft temporal to the contralateral ear Referential recording is most appropriate for measuring? - AnswerVoltage How can a defective electrode be identified? - AnswerPlacing a bad electrode with high impedance into a pin position with working non reference electrode will result high impedance To confirm the integrity of a poorly recording electrode, the tech should...? - AnswerReplace the electrode with a low impedance in the connection of the poorly recording electrode and recheck impedance 14- and -6/sec Hz positive spikes are best demonstrated with a reference to? - AnswerContralateral ear reference When using the average reference, if a spike-and-wave focus appears at C3, the abnormality would be best enhanced by? - AnswerExcluding C3 and surrounding electrodes from reference A patient with suspected asymmetrical low-voltage fast activity is observed to have a sweat artifact during the EEG recording. Which of the following EEG settings could be used to reduce the effects of the artifact? - AnswerS= 5 microvolts/mm, LFF=5 Hz, HFF = 70 Hz In a referential montage localization is determined by? - AnswerAmplitude Switching an effective electrode located in a bad pin position and a good electrode located in working pin position will result in..? - AnswerBad electrode-high impedance in a good pin position; good electrode- high impedance in bad pin position A defective headbox pin can be identified by...? - AnswerPlacing a non reference electrode with low impedance into a bad pin will result low impedance Increasing the number of seconds displayed on the monitor - AnswerDoes not change spike amplitude or duration - it shrinks the picture of the displayed waves

Mostrar más Leer menos
Institución
ABRET
Grado
ABRET








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ABRET
Grado
ABRET

Información del documento

Subido en
17 de febrero de 2025
Número de páginas
4
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:22PM. A+




ABRET (3) Exam Questions And Answers
|Latest 2025 | Guaranteed Pass.


What type of montage is shown in this sample? - Answer✔Referential Montage

Which montage would best display the amplitude of a left temporal spike? - Answer✔Left
temporal to the contralateral ear

Referential recording is most appropriate for measuring? - Answer✔Voltage

How can a defective electrode be identified? - Answer✔Placing a bad electrode with high
impedance into a pin position with working non reference electrode will result high impedance

To confirm the integrity of a poorly recording electrode, the tech should...? - Answer✔Replace
the electrode with a low impedance in the connection of the poorly recording electrode and
recheck impedance
14- and -6/sec Hz positive spikes are best demonstrated with a reference to? -
Answer✔Contralateral ear reference
When using the average reference, if a spike-and-wave focus appears at C3, the abnormality
would be best enhanced by? - Answer✔Excluding C3 and surrounding electrodes from
reference
A patient with suspected asymmetrical low-voltage fast activity is observed to have a sweat
artifact during the EEG recording. Which of the following EEG settings could be used to reduce
the effects of the artifact? - Answer✔S= 5 microvolts/mm, LFF=5 Hz, HFF = 70 Hz

In a referential montage localization is determined by? - Answer✔Amplitude
Switching an effective electrode located in a bad pin position and a good electrode located in
working pin position will result in..? - Answer✔Bad electrode-high impedance in a good pin
position; good electrode- high impedance in bad pin position

A defective headbox pin can be identified by...? - Answer✔Placing a non reference electrode
with low impedance into a bad pin will result low impedance

Increasing the number of seconds displayed on the monitor - Answer✔Does not change spike
amplitude or duration - it shrinks the picture of the displayed waves

1|Page

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Fyndlay Kaplan University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
357
Miembro desde
1 año
Número de seguidores
80
Documentos
18668
Última venta
2 días hace
Scholar\'s Sanctuary.

Explore a Vast Collection of Finely Made Learning Materials.

3.7

68 reseñas

5
32
4
8
3
13
2
6
1
9

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes