100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Sterile Processing Final Exam Practice Test Chapters 9, 14, 15, 16, 17, 18, 19, 20, 22 Questions and Answers 100% Pass

Puntuación
-
Vendido
-
Páginas
48
Grado
A+
Subido en
16-02-2025
Escrito en
2024/2025

Sterile Processing Final Exam Practice Test Chapters 9, 14, 15, 16, 17, 18, 19, 20, 22 Questions and Answers 100% Pass The system used to categorize patient care items based on the degree of risk of infection. (A) Ziehl-Neelsen Classification System (B) Medical Device Classification System (C) Spaulding Classification System (D) High-level Disinfection Classification System - C Pasteurizers disinfect using (A) heated water. (B) phenols. 2100% Pass Guarantee Olivia West, All Rights Reserved © 2025 (C) high-level disinfectants. (D) peracetic acid. - A Devices categorized as semi-critical items, must be at least (blank) prior to use. (A) high-level disinfected (B) intermediate-level disinfected (C) low-level disinfected (D) sterilized - A The use of test strips to test the minimum effective concentration in high-level disinfection solutions is required (A) weekly preferably daily. (B) daily. (C) each time the solution will be used. (D) only when manual soaking systems are used. - C The amount of time an item must remain wet with a disinfectant to achieve disinfection is called 3100% Pass Guarantee Olivia West, All Rights Reserved © 2025 (A) holding time. (B) wet contact time. (C) activation. (D) sterilization time. - B When using high-level disinfectants it is important to remember that they may be deactivated by (A) dilution. (B) organic matter. (C) time. (D) all the above. - B Items that are introduced directly into the bloodstream or other normally sterile areas of the body are classified as (A) critical items. (B) semi-critical items. 4100% Pass Guarantee Olivia West, All Rights Reserved © 2025 (C) non-critical items. (D) equipment. - A Phenolics are classified as (A) intermediate- to low-level disinfectants. (B) intermediate- to high-level disinfectants. (C) high-level disinfectants. (D) sterilants. - A When mixing several low- to intermediate-level disinfectants together, it is important to remember (A) they should be mixed in a well-ventilated room. (B) the mixture must be tested for its minimum effective concentration before use. (C) nitrile gloves should be used to protect hands. (D) chemicals should not be mixed. - D The process by which all forms of microorganisms are completely destroyed is called 5100% Pass Guarantee Olivia West, All Rights Reserved © 2025 (A) high-level disinfection. (B) thermal disinfection. (C) sterilization. (D) chemical disinfection. - C In an automated washer the key source of disinfection is (A) hydrogen peroxide. (B) water temperature. (C) heat. (D) disinfecting detergent. - B When using glutaraldehyde technicians should always w

Mostrar más Leer menos
Institución
Sterilization Process
Grado
Sterilization Process











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Sterilization Process
Grado
Sterilization Process

Información del documento

Subido en
16 de febrero de 2025
Número de páginas
48
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Sterile Processing Final Exam Practice
Test Chapters 9, 14, 15, 16, 17, 18, 19, 20,
22 Questions and Answers 100% Pass

The system used to categorize patient care items based on the degree of risk of

infection.




(A) Ziehl-Neelsen Classification System


(B) Medical Device Classification System


(C) Spaulding Classification System


(D) High-level Disinfection Classification System - ✔✔C


Pasteurizers disinfect using




(A) heated water.


(B) phenols.




100% Pass Guarantee Olivia West, All Rights Reserved © 2025 1

,(C) high-level disinfectants.


(D) peracetic acid. - ✔✔A


Devices categorized as semi-critical items, must be at least (blank) prior to use.




(A) high-level disinfected


(B) intermediate-level disinfected


(C) low-level disinfected


(D) sterilized - ✔✔A


The use of test strips to test the minimum effective concentration in high-level

disinfection solutions is required




(A) weekly preferably daily.


(B) daily.


(C) each time the solution will be used.


(D) only when manual soaking systems are used. - ✔✔C


The amount of time an item must remain wet with a disinfectant to achieve disinfection

is called




100% Pass Guarantee Olivia West, All Rights Reserved © 2025 2

,(A) holding time.


(B) wet contact time.


(C) activation.


(D) sterilization time. - ✔✔B


When using high-level disinfectants it is important to remember that they may be

deactivated by




(A) dilution.


(B) organic matter.


(C) time.


(D) all the above. - ✔✔B


Items that are introduced directly into the bloodstream or other normally sterile areas of

the body are classified as




(A) critical items.


(B) semi-critical items.




100% Pass Guarantee Olivia West, All Rights Reserved © 2025 3

, (C) non-critical items.


(D) equipment. - ✔✔A


Phenolics are classified as




(A) intermediate- to low-level disinfectants.


(B) intermediate- to high-level disinfectants.


(C) high-level disinfectants.


(D) sterilants. - ✔✔A


When mixing several low- to intermediate-level disinfectants together, it is important to

remember




(A) they should be mixed in a well-ventilated room.


(B) the mixture must be tested for its minimum effective concentration before use.


(C) nitrile gloves should be used to protect hands.


(D) chemicals should not be mixed. - ✔✔D


The process by which all forms of microorganisms are completely destroyed is called




100% Pass Guarantee Olivia West, All Rights Reserved © 2025 4

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
OliviaWest Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
106
Miembro desde
1 año
Número de seguidores
17
Documentos
8528
Última venta
2 días hace
Pure Orchid Haven.

All Documents,and package deals offered by seller Olivia West.

2.8

22 reseñas

5
6
4
2
3
4
2
1
1
9

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes