Study Guide Test.
principles of restoration - CORRECT ANSWER safety of workers & occupants // inspect & document
(initial, on-going, final) // mitigate further damage by controlling the spread of water and
contaminants// clean and dry // complete the restoration and repairs (remove excess water, water
vapor through dehumidification/ventilation/controlled temp, enhance evaporation)
commercial vs residential differences - CORRECT ANSWER 1) size & complexity of mechanical and HVAC
systems // 2) building's electrical systems vary in complexity and voltage & Training may be required //
3) Energy Management System // 4) Security and public access // 5) Multiple Interested Parties // 5)
construction practices, materials and codes are complex and varied
commercial building - CORRECT ANSWER retail, office, mixed-use, warehouse // power may be lighter
and single phase or 3 phase // type of building determines construction, HVAC and build-out density
industrial building - CORRECT ANSWER manufacturing, foundry, distribution // plenty of power // tightly
controlled security // escort may be necessary // safety training to enter // raised-floor to allow for
cabling, power distribution and process control lines
institutional building - CORRECT ANSWER public facilities (schools, hospitals, municipal buildings, sports
complexes, airports, libraries, government facilities) // issues of power availability // public access,
security // various layers of authority and organizational hierarchy // healthcare will have regulatory
agencies to sign-off of certification to re-open // decision making process may be lengthy
complex residential - CORRECT ANSWER residential facilities (townhouse, condominium, apartment
complex, hotel, multi-family dwelling, large single family mansions) // accessing units may be difficult //
condo laws define responsibility for walls and materials // units remaining wet can impact drying of
others // condos can require large amount of small equipment
historical buildings - CORRECT ANSWER all over the world // may be scattered in and around modern
buildings // often on national/local historical registries and pose unique challenges // outdated and
inadequate power // funding issues // required approval by 3rd party organizations (historical registries)
or specialized experts (preservationists)
,initial inspection priority - CORRECT ANSWER determine potential for injury, hazards and risks to
workers and occupants
HVAC varies by... - CORRECT ANSWER size and complexity varies // fire sprinklers // computer server
rooms and networks // multiple zones // understanding HVAC zones will help reduce the potential for
cross-contamination and help maintain drying environment
electrical designations - CORRECT ANSWER volts / phase / hertz
EMS - CORRECT ANSWER Energy Management System (building management systems) // EMS cycle
runtime of various systems to save energy and may be managed off site // EMS cycle varies to save
energy // might be managed off site // impact drying environment //
public access and security - CORRECT ANSWER onsite security is handled by 3rd party // security
clearances & escorts are required in secure facilities // lengthen time to mobilize equipment and
personnel // prevents theft & unauthorized entry
MIPS - CORRECT ANSWER multiple interested parties create more complexity with project
management, communication, administration // daily meetings might be scheduled // competing
agendas with varying priorities
complexities of commercial - CORRECT ANSWER multiple construction, materials, codes and practices
can converge in same building due to multiple renovations // this can cause delay
5 steps of initial visit - CORRECT ANSWER 1. Hazard Identification & Risk Assessment 2. Preliminary
Determination water category 3. Establish dry standard(s) 4. Determine drying goal(s) 5. Identify need
for specialized experts
categories of water - CORRECT ANSWER range of contamination determined by restorer /// cat 1 =
clean, little risk( water supply lines, falling rainwater) // cat 2 = discomfort or sickness (overflow from
washing machines, broken aquariums) // cat 3 = grossly contaminated (sewage and water back flow)
, class of water - CORRECT ANSWER amount of water absorption and evaporation load // class 1 = less
than 5% // Class 2 = significant, 5-40% // class 3 = greatest, more than 40% // class 4 = deeply held or
bound
dry standard - CORRECT ANSWER reasonable approximation of moisture content or level of a material
PRIOR to loss
drying goals - CORRECT ANSWER target moisture levels of materials set by restorer// within 10% of dry
standard
never... - CORRECT ANSWER assume but always verify customer's word and surrounding areas and floor
full or partial "sign off" - CORRECT ANSWER needed when returning whole or part of building
closing/final job report - CORRECT ANSWER confirms the scope of work completed & drying goals were
met
change in category - CORRECT ANSWER document explaining the reasons for degradation (time, temp,
visible contamination, odors)
regulated, hazardous, materials and mold... - CORRECT ANSWER follow local, state, federal laws!
cross contamination routes - CORRECT ANSWER elevators, hvac duct flows, building stack effect, foot
traffic
class 4 uniqueness - CORRECT ANSWER 1/2/3 = amount of water evaporating from porous surfaces // 4
= how slowly it will migrate through thick and low evap materials(very different strategy)
skills outside your expertise - CORRECT ANSWER call an expert
critical questions to ask - CORRECT ANSWER who discovered water intrusion? what has been done to
stop? what type of facility is it? Category? pre-existing damage present or suspected? Where are critical