Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 16 páginas
Examen

RESNET QAD STUDY fully solved & updated(latest verified version).

Document preview thumbnail
Vista previa 3 fuera de 16 páginas

RESNET QAD STUDY fully solved & updated(latest verified version).

Vista previa del contenido

RESNET
QAD STUDY
fully
solved &
updated(la
test

,verified
version)
Name 4 transport mechanisms for water - answer Liquid
water moves by gravity or air pressure differences, liquid
water moves through capillary action through porous
building materials, water vapor is transported via air
movement, and water vapor diffuses through the building
assemblies.


What is the biggest cause of residential building failure? -
answer Moisture


What is the order of priority for the 4 water transport
mechanisms - answer Bulk water, capillary, infiltration,
diffusion.


Bulk Water - answer Liquid water that moves by the force
of gravity and flows downhill.


Capillary - answer Water movement through (wicking)
impermeable surfaces such as concrete, brick, mortar,
wood gypsum board, and fiberglass or cellulose insulation.

, What are the components of comfort? - answer
Temperature of the surrounding air, relative humidity,
airflow across the skin (evaporative rate), mean radiant
temperature.


What is the most common type of duct material installed
today? - answer Flex duct


What are the principals of good duct design? - answer Seal
with mastic, control the flow per room requirements,
smooth turns, support the ducts properly, no take-offs
within 1' of the plenum cap or trunk end, no take-offs
within 1' of each other, no take-offs from end of trunk.
(Install in conditioned space)


What is the code required label for mastic used on flex
duct? - answer UL 181


What are some of the challenges with an oversized air
conditioner? - answer Duct leakage increases, latent
cooling decreases, more electricity is used, system short
cycle, increased wear and tear on equipment from short
cycling. Possible moisture and condensation/mold issues.


What is the Sensible Heat Ratio? - answer is calculated by
dividing the sensible load in Btu's by the total cooling load
in Btu's


What techniques are often used to provide "cost-shifting"
to improve the financial feasibility of a project? - answer

Información del documento

Subido en
11 de febrero de 2025
Número de páginas
16
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BRAINBOOSTERS
4.5
(354)
Vendido
777
Seguidores
257
Artículos
25917
Última venta
5 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes