Journeyman Electrician Practice Test Questions and Answers 100% Pass Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum THW conductors required for use as service-entrance conductors for this residence? - 4/0 AWG one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized at an ampacity of not less than 83% of the service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an allowable ampacity of 180 amperes should be selected for this dwelling. Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi- family dwelling, the full-load current rating, in amperes, of the secondary is _____. - 625 amperes To find the full-load current rating of the single-phase transformer apply the single-phase current formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes Which one of the following listed circuit breakers is NOT a standard ampere rating? - 75 amperes 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an ampere rating of 75 amperes is not a standard ampere rating. The MINIMUM length of free conductor to be left at each junction box for the purpose of splicing conductors, or making connections to illuminares or devices shall be _____ . - 6 inches free conductor is to be left at each junction box for splices or the connection of luminaires or devices. The intent of this rule is to ensure enough conductor slack for the terminal connections or splices to be made easily. In general, overhead service-drop conductors shall NOT be smaller than _____. - 8 AWG copper overhead service-drop conductors to be not smaller than 8 AWG copper or 6 AWG aluminum or copper- clad aluminum. Do not get service-drop conductors, the overhead conductors between the utility electric supply system and the service point, confused with the service-entrance conductors, the conductors from the service point from the utility company to the service disconnecting means. When a galvanized eye-bolt is to be used as the point of attachment for an electrical service, the NEC requires the eye-bolt to be installed NOT less than _____ above finished grade. - 10 ft. provide adequate vertical clearance of the conductors and prevent physical damage to the conductors and prevent persons from making accidental contact with the conductors which may create a shock hazard or electrocution. In no case shall the point of attachment of the service-drop conductors to be less than 10 ft. above finished grade. 3 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE Why is electrical continuity required for metallic conduit? - To establish an effective ground-fault path and facilitate the operation of the over-current protective device. Electrical continuity is required for metallic conduit to establish an effective ground-fault path and facilitate the operation of the overcurrent protective device. In dwelling units, receptacle outlets installed for countertop surfaces, must be located above, but NOT more than _____ above the countertop or work surface. - 20 inches receptacle outlets installed for countertop or work surfaces in dwelling units may be located on or above, but not more than 20 in. above the countertop or work surface. The intent of this rule is to eliminate the use of unsightly extension cords (which reduces the amount of usable countertop space) on the countertop or work surface to supply cord-and-plug connected appliances. Also, receptacles located more than 20 inches above countertops or work surfaces may interfere with the cabinetry to be installed. When conductors are installed in a conduit or tubing nipple of _____ or less in length, the ampacity adjustment factors for more than three (3) current-carrying conductors in the raceway, are not required to be applied. - 24 inches adjustment factors for more than three (3) current-carrying conductors in raceways shall not apply where the raceway is not more than 24 inches in length. Where more than 3 current-carrying conductors are installed in short lengths of conduit or tubing, the heating effect caused from the additional conductors is insignificant therefore, the allowable ampacity of the conductors is not greatly reduced. 4 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE In compliance with the NEC, the total marked rating of a 120-volt, cord-and-plug-connected room air conditioner shall not exceed _____ of the rating of a branch circuit when lighting units, general-use receptacles, or other appliances are supplied from the branch circuit. - 50% the special provisions for room air conditioners which are (1) rated not over 250-volts ac, single-phase and (2) which are cord-and-attachment plug connected. In order to prevent overloading the branch circuit, as per Section 40.62(C), the total rating of the A/C unit shall not exceed 50% of the rating of a branch circuit where lighting units, general-use receptacles or appliances are also supplied. What shall not be located over the steps of a stairway? - overcurrent devices "overcurrent devices shall not be located over steps of a stairway." This requirement address a serious safety issue. No one should be required to stand on different treads on a stairway to replace, repair, maintain, install, troubleshoot, or reset overcurrent devices in a panelboard or switchboard located in a stairway. Where a permanently installed outdoor swimming pool is located on residential or commercial properties, at least one (1) single-phase, 125-volt, 15- or 20-ampere receptacle shall be located not less than _____ from and not more than _____ from the inside wall of the swimming pool. - 6 feet - 20 feet

Mostrar más Leer menos
Institución
Journeyman Electrician
Grado
Journeyman electrician









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Journeyman electrician
Grado
Journeyman electrician

Información del documento

Subido en
23 de diciembre de 2024
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

1|Page




Journeyman electrician exam prep Questions and
Answers 100% Pass


What table sizes bonding jumpers for for AC systems? - ✔✔250.102(C)(1)


The NEC defines continuous load to be a load where max current on the circuit continues for at least how

many hours? - ✔✔Three


To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many current

carrying conductors in a raceway? - ✔✔Greater than three


Where in the NEC codebook would you find EMT sizes for a given size and number of conductors? -

✔✔Annex C, Table C.1


Section 210.20(A) states that the over current protection for branch circuits including continuous loads

must be greater than 100% of the noncontinuous plus ____ of the continuous load. - ✔✔125%


Liquidtight Flexible Metal Conduit shall be fastened within of each box or other conduit termination -

✔✔Twelve inches


314.28(A)(1) states that straight pulls in pull boxes with conductors size 4 AWG or larger, box length

should be greater than or equal to times the trade diameter of the largest conduit entering box. - ✔✔Eight


Chapter 9 note 4 states conduit nipples less than 24 inches can fill to a max of their cross sectional area -

✔✔60 percent


Table 348.22 gives the max number of insulated conductors in size _______ FMC? - ✔✔3/8 (trade size)




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 2|Page


Guest rooms of hotels, motels, & sleeping rooms in dorms need a MIN or _____ general purpose

receptacles installed that are readily accessible? - ✔✔Two


When branch-circuit conductors are contained inside a ballast compartment and they are within 3 inches

of the ballast, the conductors shall have a temperature rating of at LEAST _____.




a) 105 degrees C


b) 90 degrees C


c) 75 degrees C


d) 60 degrees C - ✔✔B: 90 degrees C


Ref: 410.68


Class _____ locations are those that are hazardous because of the presence of easily ignitible fibers or

materials producing combustible flyings.




a) I


b) II


c) III


d) IV - ✔✔C: III


Ref: 500.5(D)


Class _____ locations are those in which flammable gases, flammable liquid produced vapors, or

combustible liquid produced vapors are present that are explodable. - ✔✔Class 1


Class ____ locations are those that are hazardous because of combustible dust - ✔✔Class II


Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
KatelynWhitman West Virginia University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1092
Miembro desde
2 año
Número de seguidores
482
Documentos
33021
Última venta
4 horas hace
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reseñas

5
95
4
38
3
54
2
20
1
31

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes