Surgical Technology Certification Exam
Questions & Verified Answers 2024-2025 |
100% Pass Rate Guaranteed | Latest Updated
Version
The surgeon asks that multiple suture and hernia mesh that were not on the
preference card be opened during the repair of a large umbilical hernia. The
surgical technologist should recognize that:
a. items on the preference card are only to be changed by the surgeon or the
unit clerk
b. sterile supply associates who stock the hernia mesh are responsible for
adding hernia mesh to the preference card
c. preference card changes are unnecessary; both hernia mesh and suture are
case dependent.
d. suture may be case dependent, but the hernia mesh is integral to the
procedure and should be added to the preference card
Ans
Answer: D
Which of the following precautions should be taken by the surgical team when
working with polymethyl methacrylate as a bone cement?
a. wear latex free gloves, as polymethyl methacrylate interacts negatively with
latex
b. remove contact lenses as polymethyl methacrylate can melt contact lenses
and cause corneal burns
c. make sure the patient does not have a latex allergy because polymethyl
methacrylate and latex have the same chemical properties
d. Limit the # of sponges on the field as polymethyl methacrylate can
negatively interact with the cotton fibers in the sponges.
Ans
Answer: B
Which of the following daily tests must be performed on the pre-vacuum
sterilizer before using it?
a. Gravity
b. Biological indicator
c. Bowie-Dick
d. Chemical indicator
Ans
Master01 | Dec, 2024/2025 | Latest update
,Page 2 of 48 | © copyright 2024/2025 | Grade A+
Answer: C
What is the minimum exposure time in a flash sterilizer for unwrapped
instruments?
a. 1 minute
b. 3 minutes
c. 5 minutes
d. 7 minutes
Ans
Answer: B
[pre-vac] no lumen - 3 minutes ; lumen - 4 minutes
Which of the following is the correct temperature for the flash sterilizer
operation?
a. 132*C (270*F)
b. 126*C (260*F)
c. 135*C (275*F)
d. 129*C (265*F)
Ans
Answer: A
Which of the following is the proper temperature and time that the chamber of
a steam sterilizer must reach in order to ensure that all spores have been
eliminated?
a. 270*F for 4 minutes
b. 350*F for 4 minutes
c. 240*F for 10 minutes
d. 350*F for 10 mintues
Ans
Answer: A
[pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi
The Sterrad sterilization system most commonly uses which of the following
chemical solutions?
a. hydrogen peroxide
b. gluteraldehyde
c. alcohol
d. peracetic acid
Ans
Answer: A
[Sterrad] make sure its plugged in - needs electricity
Master01 | Dec, 2024/2025 | Latest update
,Page 3 of 48 | © copyright 2024/2025 | Grade A+
Which of the following is used to achieve high level disinfection with a
minimum exposure time of 20-45 minutes?
a. chlorine bleach compounds
b. gluteraldehyde
c. hydrogen peroxide
d. iodine and iodophors
Ans
Answer: B
During decontamination of a flexible endoscope, which of the following tests
should be given to inspect the proper function of the endoscope and to ensure
that it can be properly sterilized?
a. leak test
b. electrical component test
c. bacteria swab test
d. fiber optic light test
Ans
Answer: A
Which of the following is the fastest method of sterilization?
a. gas
b. steam
c. steris
d. dry heat
Ans
Answer: B
Which of the following is the correct temperature for pre-vacuum sterilization?
a. 212*F
b. 170*F
c. 300*F
d. 270*F
Ans
Answer: D
Which of the following tests is specifically meant to test and monitor the
efficiency of the high - vacuum steam sterilizer?
a. biological indicator test
b. DART test
c. chemical indicator test
d. EtO test
Ans
Master01 | Dec, 2024/2025 | Latest update
, Page 4 of 48 | © copyright 2024/2025 | Grade A+
Answer: B
DART test = Bowie Dick test
The surgical team must verify each package is properly labeled with
a. date of processing and method of sterilization
b. date of processing and indicator
c. method of sterilization and expiration date
d. indicator and expiration date
Ans
Answer: B
How many times a day should a DART test be preformed?
a. with every load
b. every shift change
c. once every 24 hours
d. weekly
Ans
Answer: C
How often must a biological control test be run?
a. every day
b. every cycle
c. once a week
d. once a month
Ans
Answer: A
[pg. 163]
The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments
Ans
Answer: B
lot control numbers should be placed on each package sterilized and on the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart
Ans
Master01 | Dec, 2024/2025 | Latest update